Installing the NEMA 4X Panel Gasket
ET 350/355 Monitors and ET 3250/3255 Computers
Intended Use
When properly installed using the materials provided, and
according to these instructions, the NEMA 4X panel gasket
is intended to provide for ET 350/355 monitors and for
ET 3250/3255 computers a NEMA 4X/IP66 seal between
the panel and the ET unit.
Warning
Read and understand all safety information
before installing and using this product.
To reduce the risk of electric shock or fire
which could result in serious personal injury or
death:
! Follow all product and accessory installation
instructions.
! Any servicing or other procedures not described in
this document are to be performed only by 3M Touch
Systems service personnel.
! Properly install the monitor or computer with a
NEMA 4X gasket that is undamaged and effective.
! Wiring installation should be done by a journeyman
electrician and must comply with federal and local
electrical codes.
To reduce the risk of electric shock which
could result in serious personal injury or death:
! Install the NEMA 4X panel gasket properly in order to
achieve a NEMA 4X seal on the front bezel.
Equipment
Materials supplied
The following materials are provided for installing
the NEMA 4X panel gasket:
! 12 Phillips #10-32 by 3/4" screws
! 12 Phillips #10-32 by 1/2" screws
! 12 flat washers
! 12 lock washers
! 1 gasket
Tools required
! Phillips No. 2 torque screwdriver
Mounting using the NEMA 4X panel
gasket
1. Use the gasket as a template to position the
cutout. Tack or tape the gasket onto the panel
where you want to mount the unit.
2. Mark the position and dimensions of the cutout
and screw holes on the panel. Cutout dimensions
are:
! Width: 14.36 inches (364.74 mm)
! Height: 12.33 inches (313.18 mm)
Caution
To reduce the risk of fire which may result in minor
or moderate injury or cause property damage:
! Provide a minimum of 1 inch (25.4 mm) clearance
behind the ET unit for proper air circulation. In warm
working environments, this depth should be increased
to provide better air circulation.
Installing the NEMA 4X Panel Gasket 3M Dynapro ET 350/355 Monitors and ET 3250/3255 Computers
3. Make the cutout and drill the holes.
8. Gently tighten each screw until some resistance
is encountered.
9. With a torque screwdriver, tighten the screws,
still in a circular sequence, to a torque of 12 inchpounds. This will take several passes, since each
pass reduces the previous torque setting.
4. Bring the power cable and the data cable
connections up to the cutout.
5. Place the bezel-mounted sealing gasket
(supplied) against the chassis of the ET unit so
that the gasket seals the gap between the panel
and the unit.
Depending on connector depth and cabinet
space, you may have to make your connections at
this point, before installing the unit in the cutout.
If so, skip to steps 10 and 11, then come back to
step 6.
6. Place the ET unit in the cutout. You may need
assistance at this point to hold the unit in place.
7. Attach the unit to the panel from the back using
the #10-32 screws that are supplied. Choose the
1/2" or 3/4" screws supplied, whichever is best
for the thickness of your panel.
Put a lock washer on each screw and then put a
flat washer on each screw (on top of the lock
washer).
10. Connect cables.
11. Connect the unit to power.
11723 (Rev. 1.2) Page 2