Installing the Rack Mount
ET 350 Monitor, ET 3170 Terminal, and ET 3200 Series Computers
Intended Use
When properly installed using the materials provided,
and according to these instructions, the rack mount is
intended to mount the ET 350 Monitor, the ET 3170
Terminal, and ET 3200 Series Computers for use in a
standard 19-inch EIA rack.
Warning
Read and understand all safety information
before installing and using this product.
To reduce the risk of fire or electric shock
which could result in serious personal injury or
death:
! Follow all product and accessory installation
instructions.
! Consideration should be given to the connection of
the equipment to the supply circuit and the effect that
overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should
be used when addressing this concern.
! Reliable earthing of rack-mounted equipment should
be maintained. Particular attention should be given to
supply connections other than direct connections to
the branch circuit (e.g., use of power strips).
Caution
To reduce the risk of fire which may result in
minor or moderate injury or cause property
damage:
! Use the materials provided so that installation of the
ET unit will not result in a hazardous condition due to
uneven mechanical loading.
! Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation
of the equipment is not compromised.
Equipment
Materials supplied
The Rack Mount Kit comes with the following items:
! 1 rack adapter (the example illustrated below is
the adapter for the ET 3170 Terminal or ET 3210
Computer)
73145_a
! 8 clip nuts
! 12 Phillips #10-32 x ½ inch panhead machine
screws
! 12 flat washers
! 12 lock washers
! 8 slotted #10-32 x 5/8 inch countersunk machine
screws
! 8 cup washers
Tools Required
! No. 2 Phillips screwdriver
! Large flat-blade screwdriver
Installing the Rack Mount 3M Dynapro ET 350 Monitor, ET 3170 Terminal and ET 3200 Series Computers
Mounting using the rack adapter
Important
If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment
may be greater than room ambient. Therefore,
consideration should be given to installing the equipment
in an environment compatible with the manufacturer’s
maximum rated ambient temperature.
To install the rack adapter in the 19-inch rack, follow
these steps:
1. To determine where to attach the clip nuts to the
rack, hold the rack adapter in the rack where you
want to mount the ET unit. Fasten the clip nuts
on the rack so that they match the locations of the
slots in the sides of the rack adapter.
The clip nuts will "clip" to the rack; screws and
washers are not required.
4. On each of the twelve #10-32 panhead machine
screws, first put on a lock washer and then put on
a flat washer.
5. Using a No. 2. Phillips screwdriver, attach each
screw (with lock washer and flat washer) through
the holes in the rack adapter and into the back of
the bezel of the ET unit.
2. Place the ET unit face down on a padded bench
or other protected surface.
3. Fit the rack adapter over the back of the ET unit,
against the back of the bezel.
6. Tighten each screw to a torque of 12 inch-
pounds.
7. If your unit requires security screws (available as
an option from 3M Touch Systems), insert them.
8. Pick up the rack adapter with the ET unit
attached and fit it to the rack. Position it to match
the locations of the clips installed earlier.
9. Fasten the adapter/ET unit to the clip nuts in the
rack with the eight slotted #10-32 x 5/8-inch
countersunk machine screws with a cup washer
on each screw.
10. Connect your data and power cables.