This is a User’s Guide for a series of products. Not all products support all firmware features.
Screenshots and graphics in this book may differ slightly from your produc t due to differences in your
product firmware or your computer operating system. Every effort has been made to ensure that the
information in this manual is accurate.
Related Documentation
• CLI Reference Guide
The CLI Reference Guide explains how to use the Command-Line Interface (CLI) to configure
the
Switch.
Note: It is recommended you use the Web Configurator to configure the Switch.
• Web Configurator Online Help
Click the help icon in any screen for help in configuring that screen and
supplementary information.
• More Information
Go to support.zyxel.com to find other information on the Switch.
Scope
Audience
Safety Instructions
Documentation C onv enti ons
8
1. Preface
1.1 Scope
This document provides an overview on RGS200-12P. It contains:
•Descriptive material about the RGS200-12P Hardware Installation Guide.
1.2 Audience
The guide is intended for system engineers or operating personnel who want to have a basic
understanding of RGS200-12P.
1.3 Safety Instructions
When a connector is removed during installation, testing, or servicing, or when an energized fiber is broken,
a risk of ocular exposure to optical energy that may be potentially hazardous occurs, depending on the
laser output power.
The primary hazards of exposure to laser radiation from an optical-fiber communication system are:
• Damage to the eye by accidental exposure to a beam emitted by a laser source.
• Damage to the eye from viewing a connector attached to a broken fiber or an energized fiber.
1.4 Documentation Conventions
The following conventions are used in this manual to emphasize information that will be of interest to the
reader.
Danger — The described activity or situation might or will cause personal injury.
Warning — The described activity or situation might or will cause equipment damage.
Caution — The described activity or situation might or will cause service interruption.
Note — The information supplements the text or highlights important points.
9
Overview
Overview
Faceplate
Panel Introduction
10
5-Port Series
2. Overview
RGS Series industrial Ethernet solutions deliver high quality, wide operation temperature range, extended
power input range and advanced VLAN & QoS features. It’s ideal for harsh environments and mission
critical applications.
2.1 Faceplate
11
12-Port Series
Front Panel
System Status LED
P1, P2 and Alarm
Gigabit Ethernet Copper Ports
RJ45
Gigabit Ethernet SFP ports
SFP Slots
POE LED
POE port statu s
RR/RS LED
Device info/status
Models
L2+ Managed Switch
RGS200-12P
Total Gigabit Ethernet Ports
12
10/100/1000 BaseT(X)
8
100/1000 Base SFP
4
2.2 Front Panel Intr oduction
12
Top Panel
Power Input (Dual)
6P Terminal Block
Console (RS232)
RJ45
Reset
Push Button
2.3 Top Panel Introduction
13
Quick Installation
Equipment Mountin g
Cable Connecting
Equipment Configuration
14
3.Quick Installation
3.1 Mounting the RGS Series (DIN-Rail)
Mounting step:
1. Screw the DIN-Rail bracket on with the bracket and screws in the accessory kit.
2. Hook the unit over the DIN rail.
3. Push the bottom of the unit towards the DIN Rail until it snaps into place.
Figure 1 RGS100-5P DIN-Rail Mounting
Figure 2 RGS200-12P DIN-Rail Mounting
15
3.2 Mounting the RGS Series (Wall mount)
Mounting step:
1.Screw on the wall-mounting plate on with the plate and screws in the accessory kit.
Figure 3 RGS100-5P Series Wall Mounting
Figure 4 RGS200-12P Series Wall Mounting
16
3.3 Ground Connections
RGS Series must be properly grounded for optimum system performance.
Figure 5 RGS100-5P Series Ground Connections
Figure 6 RGS200-12P Series Ground Connections
17
3.4 Connecting the Ethernet Interface (RJ45 Ethernet)
The switch provides two types of Ethernet interfaces: electrical (RJ45) and optical (SFP) interfaces.
Connecting the Ethernet interface via RJ45:
• To connect the switch to a PC, use straight-through or cross-over Ethernet cables.
• To connect the switch to an Ethernet device, use UTP (Unshielded Twisted Pair) or STP (Shielded Twisted
Pair) Ethernet cables.
The pin assignment of RJ-45 connector is shown in the following figure and table.
The pin assignment of RJ-45 connector is shown in the following figure and table.
1,2 T/Rx+,T/Rx- Positive V
3,6 T/Rx+,T/Rx- Negative V
4,5 T/Rx+,T/Rx- X
7,8 T/Rx+,T/Rx- X
PoE
Assignment
Port
Port
18
Fiber optics cable with LC duplex
connector
Connect the optical fiber t o t he SFP
socket
DANGER:
Never attempt to view optical connectors that might be emitting laser energy.
Do not power up the laser product without connecting the laser to the optical fiber and
3.5 Connecting the Ethernet Interface (Fiber)
Prepare a proper SFP module and install it into the optical port. Then you can connect fiber optics cabling
that uses LC connectors or SC connectors (w ith the use o f an op tional SC-to-LC adapter) to the fiber optics
connector.
an optional SC-to-LC adapter). They are also available with multimode, single mode, long-haul (for connections up to
120+ km) or special-application transceivers.
For a 1000 Mbps fiber port available, please use the mini-GBIC SFP (small form pluggable). These accept plug in
fiber transceivers that typically have an LC style connector. They are available with multimode, single mode, long-haul
(for connections up to 80+ km) or special-application transceivers.
For each fiber port there is a transmit (TX) and receive (RX) signal. Please make sure that the transmit (TX) port of
the switch connects to the receiver (RX) port of the other device, and the receive (RX) port of the switch connects to
the transmit (TX) port of the other device when making your fiber optic connections.
Refer to Table 1 for the normal operational LED status.
For a 100 Mbps fiber port available, please prepare the LC connectors or SC connectors (with the use of
putting the cover in position, as laser outputs will emit infrared laser light at this point.
19
Power Connector (6P Terminal Block)
Input
DC 12-58V
PWR1 +/-
PWR2 +/-
Power Input 2 +/-
ALM
Alarm relay output
3.6 Power Connection
The DC power interface is a 6-pin terminal block with polarity signs on the top panel.
The RGS200-12P can be powered from two power supply (input range 12V – 58V). The DC power
connector is a 6-pin terminal block; there is alarm contact on the middle terminal block.
Refer to Table 1for the normal operational LED status.
Figure 7 RGS100-5P Series Power Connections
Figure 8 RGS200-12P Series Ground Connections
Note:
20
1. The DC power should be connected to a well-fused power supply.
Power Input 1 +/-
3.7 Console Connection
The Console port is for local management by using a terminal emulator or a computer with terminal
emulation software.
• DB9 connector connect to computer COM port
• Baud rate: 115200bps
• 8 data bits, 1 stop bit
• None parity
• None flow control
Figure 10 RGS200-12P Series Ground Connections
To connect the host PC to the console port, a RJ45 (male) connector-to-RS232 DB9 (female) connector
cable is required. The RJ45 connector of the cable is connected to the CID port of RGS200-12P; the DB9
connector of the cable is connected to the PC COM port. The pin assi gnment of the console cable i s shown
below:
21
Reset Button
3.8 SYSTEM RESET
The Reset button is provided to reboot the system without the need to remove power. Under normal
circumstances, you will not have to use it. However, or rare occasions, the RGS200-12P may not respond;
then you may need to push the Reset button.
3.9 Web Interface Initialization (Optional)
Web Browser Support
IE 7 (or newer version) with the following default settings is recommended:
Language script Latin based
Web page font Times New Roman
Plain text font Courier New
Encoding Unicode (UTF-8)
Text size Medium
Firefox with the following default settings is recommended:
Web page font Times New Roman
Encoding Unicode (UTF-8)
Text size 16
22
Google Chrome with the following default settings is recommended:
Web page font Times New Roman
Encoding Unicode (UTF-8)
Text size Medium
Connect & Login to RGS200-12P
1. Connecting to RGS200-12P Ethernet port (RJ45 Ethernet port).
1. Connecting to RGS200-12P Ethernet port(RJ45 Ethernet port)
2. Key-in the command under Telnet: telnet 192.168.1.1
3. Login with default account and password.
Username: admin
Password: 1234
4. Change the IP with commands listed below:
CLI Command:
configure terminal
interface vlan 1
ip address xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx
exit
24
3.11 Monitoring the Ethernet Interface
By RJ45 Ethernet:
Refer to Figure 11
refer to Table
LED Indicator s for monitoring 8 Gigabit Ethernet with copper connector (RJ45). Also
1 for the normal operational LED status.
By SFP:
Refer to Figure 11
Table
1 for the normal operational LED status.
LED Indicator s for monitoring 4 Gigabit Ethernet with SFP connector. Also refer to
3.12 Upgrade Software
1. In Web UI, go to “MaintenanceSoftwareUpload” page.
2. Select software file, and click “Upload” button.
3. After starting to upload software to device, please don’t cold/w arm s tart device and wait it auto reboot,
then upgrade finished.
25
3.13 Reset to Default and Save Configure
Configuration via CLI com m a nd
To see what current interface and IP address is:
If the manager wants to reset the configuration to default, but keep management IP setting.
(1) Please execute this command: reload defaults keep-ip
(2) Check interface VLAN and IP address; confirm only management IP setting kept.
(3) Execute this command: copy running-config startup-config
If manager want to reset the all configuration to default completely
(1) Please execute this command: reload defaults
(2) Check interface VLAN and IP address, confirm they all change to default setting.
(3) Execute this command: copy running-config startup-config
26
Configuration via WEB UI
If manager want to reset the configuration to default but keep management IP setting
(1)Go to “Maintenance””Factory Defaults” pagination to Click “Yes” button.
(2) Go to “Maintenance” “Configuration””Save startup-config” pagination, then click “Save
Configuration” button, then reset successfully
.
If manager want to reset the all configuration to default completely
(1) Go to “Maintenance” “Configuration””Activate” pagination to select “default-config”, then click
“Activate Configuration” button
27
(2) Change WEB’s IP be 192.0.2.1(default IP) to login DUT’s Web UI.
(3) Go to “Maintenance” “Configuration””Save startup-config” pagination, then click “Save
Configuration” button, then reset successfully.
28
Pin
No#
Status
5-Port (4TX+1SFP) with PoE
Pin 1
ON
To enable Broadcast storm rate limit
OFF
To disable Broadcast storm rate limit
Pin 2
ON
NOT USED
OFF
NOT USED
Off
P1/P2 power line disconnect or does not have power supplied
On Red
Ethernet link fails, alarm or power failure alarm occurs
On Green
Ethernet link up but no traffic is detected
Off
Ethernet link down
On Yellow
A 1000Mbps connection is detected
ct
3.14 DIP Switch Setting for RGS100-5P
3.15 LED STATUS INDI CATIONS
Table 1 LED Status Indica tors
LED
Name
P1/P2
Alarm
Copper
port
Link/Act
Copper
port
Speed
SFP
port
Link/A
SFP
port
Speed
Indicator
/color
On Green P1/P2 power line has power
Off No Et her net link fails and no power failure alarm
Flashing
Green
Off No link , a 10Mbps or 100 Mbps connection is detected
On Green Ethernet link up
Off Et hernet link down
On Yellow SFP port speed 1000Mbps connection is detected.
Off No link or a SFP port speed 100Mbps connection is detected
Condition
Ethernet link up and there is traffic detected
On Green POE is working
POE
Off PO E is not working
29
ALM LED Indicator
Copper Speed LED
Copper Link/Act LED
SFP Speed LED
Indicator
SFP Link LED Indicator
PWR LEDIndicator