Zte ZXA10 C300 Maintenance Manual

ZXA10C300
OpticalAccessConvergenceEquipment
MaintenanceManual
Version:V2.0.0
ZTECORPORATION No.55,Hi-techRoadSouth,ShenZhen,P .R.China Postcode:518057 Tel:+86-755-26771900 Fax:+86-755-26770801 URL:http://support.zte.com.cn E-mail:support@zte.com.cn
LEGALINFORMATION
Copyright©2014ZTECORPORATION.
Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionor
distributionofthisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwritten
consentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedby
contractualcondentialityobligations.
Allcompany ,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTE
CORPORATIONoroftheirrespectiveowners.
Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditions
aredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,tnessforaparticularpurpose,
titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromthe
useoforrelianceontheinformationcontainedherein.
ZTECORPORA TIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplications
coveringthesubjectmatterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTE
CORPORATIONanditslicensee,theuserofthisdocumentshallnotacquireanylicensetothesubjectmatter
herein.
ZTECORPORA TIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice.
UsersmayvisittheZTEtechnicalsupportwebsitehttp://support.zte.com.cntoinquireforrelatedinformation.
TheultimaterighttointerpretthisproductresidesinZTECORPORATION.
RevisionHistory
RevisionNo.RevisionDateRevisionReason
R1.02013-06-30Firstedition
SerialNumber:SJ-20130520164529-008
PublishingDate:2013-06-30(R1.0)
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Contents
AboutThisManual.........................................................................................I
Chapter1SafetyDescriptions..................................................................1-1
1.1SafetyPrecautions.............................................................................................1-1
1.2SignDescriptions...............................................................................................1-2
Chapter2RoutineMaintenance................................................................2-1
2.1RoutineMaintenancePrecautions.......................................................................2-1
2.2EquipmentRoutineMaintenance.........................................................................2-2
2.2.1EnvironmentCheck..................................................................................2-2
2.2.2EquipmentStatusCheck..........................................................................
2-3
2.2.3SwitchingandControlCardRunningStatusCheck....................................2-5
2.2.4PONInterfaceCardRunningStatusCheck................................................2-6
2.2.5EthernetUplinkCardRunningStatusCheck..............................................
2-8
2.2.6EthernetInterfaceCardRunningStatusCheck.........................................
2-11
2.2.7P2PInterfaceCardRunningStatusCheck...............................................
2-12
2.2.8TDMInterfaceCardRunningStatusCheck..............................................2-12
2.2.9CommonInterfaceCardRunningStatusCheck.......................................2-14
2.2.10PowerInterfaceCardRunningStatusCheck..........................................2-14
2.3NMSRoutineMaintenance...............................................................................2-15
2.3.1MonitoringAlarmsinRealTime...............................................................2-15
2.3.2CheckingNEDataBackupStatus...........................................................
2-19
2.3.3MonitoringNMSPerformance.................................................................
2-21
2.3.4DetectingVirus.......................................................................................
2-25
Chapter3DataBackupandRecovery......................................................
3-1
3.1ConguringFTPServices...................................................................................
3-1
3.2NEDataSaving.................................................................................................3-3
3.2.1SavingNEDatainRealTime....................................................................3-3
3.2.2SavingNEDataPeriodically.....................................................................
3-4
3.3NEDataBackup................................................................................................3-7
3.3.1BackingUpNEDatainRealTime.............................................................3-7
3.3.2BackingupNEDataPeriodically...............................................................
3-8
3.4RestoringNEData............................................................................................3-11
3.5PerformingActive/StandbyCardChangeover....................................................3-12
Chapter4ExpansionGuides.....................................................................4-1
I
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter5CutoverGuides.........................................................................5-1
Chapter6VersionUpgradeGuides..........................................................
6-1
6.1Overview...........................................................................................................6-1
6.1.1VersionInformation..................................................................................6-1
6.1.2UpgradingPrecautions.............................................................................6-2
6.1.3UpgradingT ools.......................................................................................6-2
6.1.4UpgradingPreparations............................................................................6-2
6.2UpgradingVersions............................................................................................6-5
6.3UpgradingPatches.............................................................................................
6-7
6.4T estingUpgradingResults..................................................................................6-9
6.5ProcessingGuidesforUpgradeFailure..............................................................
6-10
AppendixACardReplacement................................................................
A-1
A.1CardReplacementPrecautions..........................................................................A-1
A.2ReplacingSwitchingandControlCard................................................................
A-1
A.3ReplacingOtherCards.......................................................................................
A-4
Glossary..........................................................................................................I
II
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
AboutThisManual
Purpose
Thismanualprovidesproceduresandguidelinesthatsupportthemaintenanceofthe ZXA10C300OpticalAccessConvergenceEquipment.
IntendedAudience
Thisdocumentisintendedfor:
lDebuggingengineer lNMmonitoringengineer lMaintenanceengineer
WhatIsinThisManual
Thismanualcontainsthefollowingchapters:
ChapterSummary
1,SafetyDescriptionsProvidesthesafetyprecautionsandsign
description.
2,RoutineMaintenanceDescribestheroutinemaintenanceatboththe
equipmentsideandtheNMside.
3,DataBackupandRecoveryDescribesthesavingandbackupoftheNEdata.
4,ExpansionGuidesDescribestheexpansionowandtheprocessing
guidesforexpansionfailure.
5,CutoverGuidesDescribesthecutoverowandthecutover
restoringguides.
6,VersionUpgradeGuidesDescribestheversionupgradingowsand
upgradingfailureguides.
AppendixA,CardReplacementDescribesthecardreplacement.
Conventions
Thismanualusesthefollowingtypographicalconventions:
TypefaceMeaning
ItalicsVariablesincommands.Itmayalsorefertootherrelatedmanualsanddocuments.
BoldMenus,menuoptions,functionnames,inputelds,optionbuttonnames,check
boxes,drop-downlists,dialogboxnames,windownames,parameters,and
commands.
ConstantwidthTextthatyoutype,programcodes,lenames,directorynames,andfunctionnames.
I
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
TypefaceMeaning
[]Optionalparameters.
{}Mandatoryparameters.
|Separatesindividualparametersinaseriesofparameters.
Danger:indicatesanimminentlyhazardoussituation.Failuretocomplycanresult
indeathorseriousinjury,equipmentdamage,orsitebreakdown.
Warning:indicatesapotentiallyhazardoussituation.Failuretocomplycanresultin
seriousinjury,equipmentdamage,orinterruptionofmajorservices.
Caution:indicatesapotentiallyhazardoussituation.Failuretocomplycanresultin
moderateinjury,equipmentdamage,orinterruptionofminorservices.
Note:providesadditionalinformationaboutacertaintopic.
II
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter1
SafetyDescriptions
TableofContents
SafetyPrecautions.....................................................................................................1-1
SignDescriptions.......................................................................................................1-2
1.1SafetyPrecautions
SafetyPrecautionsforProtectionGround
Thesafetyprecautionsforprotectiongroundareasfollows:
lConnectthegroundingcablerstbeforeinstallingtheequipment.Removethe
groundingcableafterremovingalltheequipment.
lProhibittodestroythegroundingconductor . lProhibittooperateontheequipmentwithoutinstallingthegroundingconductor. lTheequipmentmustbeconnectedwiththeprotectiongroundperpetually.Before
operatingontheequipment,checktheelectricalconnectionandmakesurethatthe equipmentgroundingisreliable.
SafetyPrecautionsforBatteries
Thesafetyprecautionsforthestoragebatteryareasfollows:
lAlwayskeeptheelectrodesofabatteryfacingupwardinmovingabattery.Donotput
itupsidedownortiltit.
lAvoidshort-circuitofabatterycausedbymetalobjects.Ifpossible,cutoffthepower
supplyofthebatterybeforeperformingotheroperations.
lDuringitsworking,batterieswillreleaseinammablegas,sotheyshouldbeplacedin
theenvironmentwhichiswellventilatedwithproperrepreventionmeasurestaken.
lWhenabatteryisover60℃intemperature,checkitforanyspillofacidliquid.Handle
timelyifthereisanyspillofacidliquid.
lWhenmovingorhandlingabatterywithleakage,becarefultoprotectyourselffrom
anypossibleharmbytheacidliquid.UseNaHCO
3
,Na
2
CO
3
orNa
2
CO
3
10H
2
Oto
neutralizeorabsorbthemifanyspillofacidliquidisfound.
lWashwithcleanwaterifanyonetouchesanyspillofthebattery.Ifthesituationis
quiteserious,takehimtothehospitalafterwashingwithcleanwater.
Thesafetyprecautionsfortheli-ionbatteryareasfollows:
lReplacewiththesametypeofbatteryrecommendedonly . lHandletheused-upbatteryaccordingtoinstructionsonly. lDonotthrowtheli-ionbatteryintothere.
1-1
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
ZXA10C300MaintenanceManual
SafetyPrecautionsforLaser
Thelaserreceiverandtransmitterisusedintheopticaltransmissionsystemandtherelated testtools.Thebaredopticalberortheconnectorportcantransmitlaserwhichisinvisible tothenakedeyes.Lookingatitwithoutanyprotectionmayhurteyes.
Theeyesarenothurtifyougazeatthebaredopticalbertipsordamagedopticalberin adistanceof150mm.Buttheeyesmaybehurtifyouobservethebaredopticalbertip withamicroscope,amagnieroraloupe.
Thesafetyprecautionsforlaserareasfollows:
lOnlytheauthorizedpersonnelwiththecorrespondingtrainingcanperformthe
operation.
lWearsafetygoggleswhilehandlinglaseroropticalbers. lMakesuretoswitchofftheopticalsourcebeforedisconnectingtheopticalber
connector.
lProhibittogazeatthebareopticalberortheconnectortipsbeforetheopticalsource
issurelyswitchedoff.
lMeasuretheopticalpowerintheopticalberwithanopticalpowermetertomake
suretheopticalsourceisswitchedoff.
lWhenopeningthefrontdooroftheopticalbertransmissionsystem,becarefulto
avoidthelaserradiation.
lProhibittouseopticalinstrumentincludingthemicroscope,themagnierortheloupe
toobservetheopticalberconnectorortheopticalbertips.
Doasfollowswhenhandlingtheopticalbers:
lOnlythepersonnelwithcorrespondingtrainingcanshear,fuseandsplicetheoptical
ber.
lMakesuretheopticalberandopticalsourceisdisconnectedbeforeshear,fuseand
splicetheopticalver.Afterdisconnectingtheopticalber,protectalltheopticalber connectorswiththeopticalbercaps.
SafetyPrecautionsforPlugging/UnpluggingCards
Thesafetyprecautionsforplugging/unpluggingcardsareasfollows:
lMakesurethatthecardiscompatiblewiththeslot. lWeartheantistaticwriststripbeforeoperation. lPluginthecardalongslidingrail.Ifthecardisblocked,donotshakethecardto
preventanydamagetothecard.
1.2SignDescriptions
Table1-1liststhesafetysignsusedinthismanual.Thesesignsremindusersofthe
safetyprecautionswhichtheyhavetoconsiderduringthedeviceinstallation,operation andmaintenance.
1-2
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter1SafetyDescriptions
Table1-1SafetySignandDescription
SafetysignDescription
Safetyprecautionsign
Notesign
Thesafetypromptsconsistsofthreelevels:Danger,WarningandCaution.Thedetails areasfollows:
Danger!
Indicatesanimminentlyhazardoussituation,which,ifnotavoided,couldresultindeath, seriousinjury ,orseriousequipmentdamages.
Warning!
Indicatesahazardoussituation,which,ifnotavoided,couldresultinseriousinjuries, equipmentdamagesorservicesinterruption.
Caution!
Indicatesapotentiallyhazardoussituation,which,ifnotavoided,couldresultinmoderate injuries,equipmentdamagesorinterruptionofpartialserviceinterruption.
Note:
Indicatesthenotes,promptsandtips.
1-3
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
ZXA10C300MaintenanceManual
Thispageintentionallyleftblank.
1-4
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter2
RoutineMaintenance
TableofContents
RoutineMaintenancePrecautions..............................................................................2-1
EquipmentRoutineMaintenance................................................................................2-2
NMSRoutineMaintenance.......................................................................................2-15
2.1RoutineMaintenancePrecautions
Theprecautionsfortheroutinemaintenanceareasfollows:
lKeeptheequipmentroomclean,andmaintainnormaltemperatureandhumiditylevel.
Takespecialmeasurestokeepitdust-proofanddamp-proof,andothermeasures againstinsectsandrodents.
lEnsurethattheprimarypowerisstableandreliable;checkthesystemgrounding
andlightninggroundperiodically.Inparticular,checkthelightningprotectionsystem beforeandafterthestormyseasonfortheprotectionofthefacilities.
lEstablishacompletesetofmaintenanceregulationsfortheequipmentroomto
standardizetheroutinemaintenancework.Detailedmaintenanceattendancelog shouldbemaintainedaboutsystemoperation,softwareversion,conguration change,upgradingandtroubleshootingrecordsforfaultanalysisandsolutionsinthe future.
lItisprohibitedtoplaygames,accessInternetoncomputerterminalsandsetup,run,
copyanysoftwarethatisirrelevanttothesystemorapplythecomputerterminalfor otherintention.
lConguredifferentNMpasswordsfordifferentaccessrightsandputthemunder
authorizedmanagement.Changethepasswordsperiodicallywithonlyauthorized personnelhavingtheaccess.
lMaintenancepersonnelshouldbewelltrainedandshouldhavesoundexperienceof
computernetworks,andwillstudyfurthertoimprovetheirmaintenanceskills.During maintenanceoperations,maintenancepersonnelshouldfollowtherelevantmanual. Wearantistaticwriststrapbeforetouchingthehardwareoftheequipmenttoavoid staticdischarge.
lDonotresettheequipment,loadorchangeanydata,especiallytheNEdataunless
itisnecessary.Backupsystemcongurationbeforeanychangeismadeonitand donotdeletebackupcongurationlesuntilthesystemisrunningproperly(generally afteraweek.Timelyrecordisnecessaryforanychangeonthedata.
lPrepareatoolkitoffrequentlyusedtoolsandcalibratethemetersregularlytoensure
theyareworkingproperly.Theninetoolsareasfollows:
àScrewdriver(Straight,Cross)
2-1
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
ZXA10C300MaintenanceManual
àSignalingtesters
àThinnosebentpliers
àNetworkcablepliers
àMulti-meters
àACpowermaintenance
àPowerextensionlinesandsockets
àTelephonecables
àNetworkcables
lCheckstandbyequipmentregularlytomaintaininventoryandlabelthemfor
convenience.Storethesparecomponentsandreplacedfaultycomponentinto correspondingproperplacesandlabelthemforidentication.
lKeepthesoftwareanddocumentswellarrangedandkeepthemataneasily
accessibleplaceatthetimeofmaintenanceactivity.
lTheequipmentroomshouldbewelllightenedforthemaintenancetasks.Incaseof
powerfailure,makenecessaryemergencyarrangements.
lPutthecontactinformationofZTECorporationlocalofceatanoticeableplaceand
informthemaintenancepersonnelofthisandseekhelpincaseofemergency.Update thecontactinformationtimely .
2.2EquipmentRoutineMaintenance
Theequipmentroutinemaintenanceincludesenvironmentcheck,equipmentstatuscheck, andcardsstatuscheck.
2.2.1EnvironmentCheck
Table2-1liststheenvironmentcheckitems.
Table2-1EnvironmentCheck
ItemInstrumentand
Meter
TestingMethodReference
Standard
Troubleshooting
Equipmentroom
temperature
control
ThermometerCheckandrecord
thecurrentvalue
-5℃to45℃(long
term)
-5℃to5℃(short
term)
Adjusttheair
conditioneror
othertemperature
controldevices
Equipmentroom
humidity
HygrometerCheckandrecord
thecurrentvalue
5%to95%Adjusttheair
conditioneror
otherhumidity
controldevices.
2-2
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter2RoutineMaintenance
ItemInstrumentand
Meter
TestingMethodReference
Standard
Troubleshooting
Equipmentroom
dustresistance
NoneObservethedust
concentrationin
theequipment
room
Theconcentration
ofthedustwitha
diameterlarger
than5μmis
nomorethan
3×10
4
particles/
m3.The
dustparticles
shouldbe
non-conductive,
non-magnetic,
electricalor
corrosive.
Asitisdifcultto
measurethedust
concentrationin
theequipment
roomindaily
maintenance,
themaintenance
personnelmust
makesurethe
equipmentisnot
coveredwithdust
orpolluted.
Airconditioner
runningstatus
NoneCheckwhether
theairconditioner
(orother
temperatureand
humidityadjusting
devices)can
workproperly
accordingtothe
settemperature
(humidity).
Refertotheset
temperatureand
humidityvalues
oftheequipment
room.
Iftheair
conditioneris
faulty,contactthe
airconditioner
maintenance
personnelto
repairit.
StoragebatteryMulti-meterMaintenance
personnel
measurethe
ACandDC
voltagesofthe
inputpowerwith
amulti-meterand
keeparecord.
-48V±15VIfthestorage
batteryvoltageis
notstable,contact
therelative
departmentfor
maintenance.
2.2.2EquipmentStatusCheck
Overview
ThecheckontheZXA10C300runningstatusincludesthefollowing:
lPowercableandgroundingcablecheck lPowersupplyandvoltagecheck lFanrunningstatuscheck
2-3
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
ZXA10C300MaintenanceManual
lCardrunningstatuscheck
PowerCableandGroundingCableCheck
Table2-2liststhepowercableandgroundingcablecheckinformation.
Table2-2PowerCableandGroundingCheck
ItemStep
MetersNone
CheckmethodCheckwhetherthepowercableandthegroundingcableareproperly
connectedandwhethertheyarerusty.
StandardrequirementsThepowercableandthegroundingcableareconnectedproperly
andtheyarefreeofrust.
TroubleshootingIfthepowercableandthegroundingcablearenotconnectedproperly ,
pleasereconnectorchangethem.
PowerSupplyandVoltageCheck
Table2-3liststhepowersupplyandvoltagecheckinformation.
Table2-3PowerSupplyandVoltageCheck
ItemStep
MetersMultimeter
CheckmethodMaintenancepersonnelmeasuretheACandDCvoltagesoftheinput
powerwithamultimeterandkeeparecord.
Standardrequirements1.TheZXA10C300uses–48Vpowersupply.Theequipmentroom
shouldbeinstalledwithAC/DCpowertransformingequipment
tosupplyworkingpower.TheDCpowervoltageisallowedto
uctuatebetween–57Vand–38V.
2.InordertoensurecontinuousworkingoftheZXA10C300device
incaseofthemainspowerfailure,itisnecessarytoprovidethe
uninterruptedpowersupplymeasures,suchasdiesel-electricset
andstoragebattery.
3.DCpowersupplyshallhaveover-voltage/currentprotectionand
indication.
TroubleshootingWhenthetestresultisnotinthestandardrange,pleasecheckthe
inputpowersupplytimelyandmakesurethebackuppowersupplyis
intheworkingstatus.
FansRunningStatusCheck
Table2-4liststhefanrunningstatuscheckinformation.
2-4
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter2RoutineMaintenance
Table2-4FansRunningStatusCheck
ItemStep
MetersNone
CheckmethodChecktherunningstatusofthefanswiththeshowfancommand.If
theequipmentroomisatthelocalplace,observethefanrunning
statusdirectlyandkeeparecord.
StandardrequirementsThefanrunsproperly.
TroubleshootingIfthefanisfaulty ,informthemaintenancepersonneltorepairit.
CardRunningStatusCheck
TheLEDstatesindicatethecardrunningstatus.
Table2-5liststhecardrunningstatescheckinformation.
Table2-5CardRunningStatesCheck
ItemStep
MetersNone
CheckmethodChecktherunningstatusofthecardswiththeshowcardcommand.
Iftheequipmentroomisatthelocalplace,observethefanrunning
statusdirectlyandkeeparecord.
StandardrequirementsThecardsrunproperly.
TroubleshootingIfthecardisfaulty ,informthemaintenancepersonneltorepair .
Youcanalsocheckcardrunningstatusthroughindicatorsonthecardpanel.
2.2.3SwitchingandControlCardRunningStatusCheck
TheZXA10C300usesthefollowingswitchingandcontrolandcards:
lTM-levelswitchingandcontrolcard:SCTM lType-Nswitchingandcontrolcard:SCXN
Table2-6liststheindicatordescriptionsforthecontrolandswitchingcards.
Table2-6IndicatorDescriptionofControlandSwitchingCards
IndicatorStatusDescription
OFFThecardisnotpoweredonorCPUisnotstarted.
GreenLEDashesslowly.Thecardworksproperlyandcardtype
congurationiscorrect.
GreenLEDisON.Thecardisnotcongured.
GreenLEDashesquickly.Thecardisdownloadingdata.
RedLEDisON.Cardhardwarefailure
RUN
2-5
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
ZXA10C300MaintenanceManual
IndicatorStatusDescription
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
GreenLEDisON.Thecardisactive. M/S
OFFThecardisstandby.
HDDRedThecontrolandswitchingcardisoperatingash.
Cardplug-in/plug-outisnotallowed.
GreenLEDisON.Thelinkisestablished.
GreenLEDashes.Theopticalinterfaceissendingandreceivingdata.
ACTi(i=1-4
OFFThelinkisnotestablished.
2.2.4PONInterfaceCardRunningStatusCheck
TheZXA10C300usesthefollowingPONinterfacecards:
lGPONinterfacecard:GTGHandGTGO lXG-PON1interafcecard:GTXOandGTXQ
GPONInterfaceCardRunningStatus
Table2-7describestheindicatorsoftheGPONinterfacecards.
Table2-7IndicatorDescriptionofGPONInterfaceCards
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromthenetwork
managementserver.
GreenLEDashesslowly
everytwoseconds.
Thecardrunsproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
RUN
2-6
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter2RoutineMaintenance
IndicatorStatusDescription
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
LEDisOFF .lNoONUisconguredontheGPONinterface.
lTheGPONinterfacehasnoopticalmodule
installed.
lTheGPONinterfaceisshutdown.
lTheGPONinterfaceisTypeBprotectionport.
GreenLEDashes.TheGPONinterfaceandconnectedONUswork
properly.
ACTi/LEDi(i=1
-16)
RedLEDisON.TheGPONinterfacehasLOSalarms.
XG-PON1InterfaceCardsRunningStatus
Table2-8describestheindicatorsoftheXG-PON1interfacecards.
Table2-8IndicatorDescriptionofXG-PON1InterfaceCards
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromthenetwork
managementserver.
GreenLEDashesslowly
everytwoseconds.
Thecardrunsproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
2-7
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
ZXA10C300MaintenanceManual
IndicatorStatusDescription
OFFlNoONUisconguredontheXG-PON1
interface.
lTheXG-PON1interfacehasnoopticalmodule
installed.
lTheXG-PON1interfaceisshutdown.
lTheXG-PON1interfaceisTypeBprotection
port.
GreenLEDashes.TheXG-PON1interfaceandconnectedONUs
workproperly.
ACTi(i=1-8)
RedLEDisON.TheXG-PON1interfacehasLOSalarms.
2.2.5EthernetUplinkCardRunningStatusCheck
TheZXA10C300usesthefollowingEthernetuplinkcards:
l10GEEthernetuplinkcard:XUTQandXUVQ l10GE/40GEEthernetuplinkcard:HUKQ l10GE/GEEthernetuplinkcard:HUTQandHUVQ lGEEthernetuplinkcard:GUFQ,GUSQ,GUTQ,andHUGQ
10GEEthernetUplinkCard
Table2-9describestheindicatorsofthe10GEEthernetuplinkcards.
Table2-9IndicatorDescriptionof10GEEthernetUplinkCard
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromtheswitching
andcontrolcardorthenetworkmanagement
server.
GreenLEDashesslowly
everytwoseconds.
Thecardrunsproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
RUN
2-8
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter2RoutineMaintenance
IndicatorStatusDescription
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
GreenLEDisOFF.The10GEopticalinterfaceisnotconnectedorthe
linkisnotestablished.
GreenLEDisON.The10GEopticalinterfaceisconnected(LINK).
ACTi(i=1–4)
GreenLEDashes.The10GEopticalinterfaceissendingand
receivingthedata(ACTIVE).
10GE/40GEEthernetUplinkCard
Table2-10describestheindicatorsofthe10GE/40GEEthernetuplinkcard.
Table2-10IndicatorDescriptionof10GE/40GEEthernetUplinkCard
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromtheswitching
andcontrolcardorthenetworkmanagement
server.
GreenLEDashesslowly
everytwoseconds.
Thecardrunsproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
GreenLEDisOFF.Theopticalinterfaceisnotconnectedorthelink
isnotestablished.
GreenLEDisON.Theopticalinterfaceisconnected(LINK).
ACTi(i=1–4)
GreenLEDashes.Theopticalinterfaceissendingandreceivingthe
data(ACTIVE).
10GE/GEEthernetUplinkCard
Table2-11describestheindicatorsofthe10GE/GEEthernetuplinkcards.
2-9
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
ZXA10C300MaintenanceManual
Table2-11IndicatorDescriptionof10GE/GEEthernetUplinkCard
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromtheswitching
andcontrolcardorthenetworkmanagement
server.
GreenLEDashesslowly
everytwoseconds.
Thecardrunsproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
GreenLEDisOFF.Theopticalinterfaceisnotconnected.
GreenLEDisON.Theopticalinterfaceisconnected(LINK).
XG1/XG2/GE1/
GE2
GreenLEDashes.Theopticalinterfaceissendingandreceivingthe
data(ACTIVE).
GEEthernetUplinkCard
Table2-12describestheindicatorsoftheGEEthernetuplinkcards.
Table2-12IndicatorDescriptionofGEEthernetUplinkCard
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromthemaincontrol
andswitchingcardorthenetworkmanagement
server.
RUN
2-10
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter2RoutineMaintenance
IndicatorStatusDescription
GreenLEDashesslowly
everytwoseconds.
Thecardrunsproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
GreenLEDisOFF.Theinterfaceisnotconnected.
GreenLEDisON.Theinterfaceisconnected(LINK).
ACTi(i=1–4)
GreenLEDashes.Theinterfaceissendingandreceivingthedata
(ACTIVE).
2.2.6EthernetInterfaceCardRunningStatusCheck
TheZXA10C300usesthefollowingEthernetinterfacecards:
l8-portGEEthernetinterfacecard:GDFO l2-port10GEand8-portGEEthernetinterfacecard:HDTT
Table2-13describestheindicatorsoftheEthernetinterfaceCards.
Table2-13IndicatorDescriptionofEthernetInterfaceCards
IndicatorStatusDescription
OFFThecardpowersOFForCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashesquickly .Thecardisdownloadingdatafromthemaincontrol
cardorNM.
GreenLEDashesslowly
everytwoseconds.
Thecardisworkingproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardshouldnotbeinsertedinthisslot.
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
2-11
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
ZXA10C300MaintenanceManual
IndicatorStatusDescription
GreenLEDisOFF.Theopticalinterfaceisnotconnected.
GreenLEDisON.Theopticalinterfaceisconnected(LINK).
ACTi(i=1–8)/1
–8/X1–X2
GreenLEDashes.Theopticalinterfaceissendingandreceivingthe
data(ACTIVE).
2.2.7P2PInterfaceCardRunningStatusCheck
TheZXA10C300usestheFTGKP2Pinterfacecard.
Table2-14describestheindicatorsoftheP2PEthernetinterfacecard.
Table2-14IndicatorDescriptionofP2PInterfaceCard
IndicatorStatusDescription
OFFThecardpowersOFForCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromthecontrolandswitchingcard
orNM.
GreenLEDashesquickly .Thecardisdownloadingdatafromtheswitching
andcontrolcardorNM.
GreenLEDashesslowly
everytwoseconds.
Thecardisworkingproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardshouldnotbeinsertedinthisslot.
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatofthecontrolandswitchingcard.Auto-update
isnotconguredonthecard.
GreenLEDisOFF.Theopticalinterfaceisnotconnectedorthelink
isnotestablished
GreenLEDisON.Theopticalinterfaceisconnected(LINK).
LEDi(i=1-48)
GreenLEDashes.Theopticalinterfaceissendingandreceivingthe
data(ACTIVE).
2.2.8TDMInterfaceCardRunningStatusCheck
TheZXA10C300usesthefollowingTDMinterfacecards:
lSTM-Ncircuitemulationinterfacecard:CTLA lE1circuitemulationinterfacecard:CTUB
2-12
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Chapter2RoutineMaintenance
CTLACard
Table2-15describestheindicatorsoftheCTLAcard.
Table2-15IndicatorDescriptionoftheCTLACard
IndicatorStatusDescription
OFFThecardpowersOFForCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashesquickly.Thecardisdownloadingdatafromtheswitching
andcontrolcardorNM.
GreenLEDashesslowly
everytwoseconds.
Thecardisworkingproperly .
RedLEDisON.Thecardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thiscardshouldnotbeinsertedinthisslot.
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionoflinecarddoesnotmatch
thatoftheswitchingandcontrolcard.Theservice
isnormal.
GreenLEDisOFF.ThecardisintheSTM-1interface(155M)mode. MOD
GreenLEDisON.ThecardisintheSTM-4interface(622M)mode.
TwogreenLEDsareON.OpticalmoduleisON.Sendingorreceivingis
normalwithoutalarms.
TwogreenLEDsareOFF .OpticalmoduleisOFFwithoutbeingcongured.
RXRedLEDisON.Opticalsignalloses.Frameloses.Oralarmis
generatedinmultiplexsection.
TX/RX
TXRedLEDisON.Theremoteendisinvalid.
CTUBCard
Table2-16describestheindicatorsoftheCTUBcard.
Table2-16IndicatorDescriptionoftheCTUBCard
IndicatorStatusDescription
OFFThecardpowersOFForCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromswitchingandcontrolcardorNM.
GreenLEDashesquickly.Thecardisdownloadingdatafromtheswitching
andcontrolcardorNM.
RUN
2-13
SJ-20130520164529-008|2013-06-30(R1.0)ZTEProprietaryandCondential
Loading...
+ 52 hidden pages