ZiLOG UM018112-0908 User Manual

Copyright ©2008 by Zilog®, Inc. All rights reserved.
www.zilog.com
USB Smart Cable
User Manual
UM018112-0908
USB Smart Cable
User Manual
UM018112-0908 Revision History
ii
Revision History
Each instance in the Revision History table reflects a change to this docu­ment from its previous revision.
Date
Revision Level Description
Page Number
September 2008
12 Updated Connecting to the
Target Board
6
April 2008 11 Updated USB Smart Cable
Firmware Compatibility. Updated Installing the USB Smart Cable and Driver
2 and 3
December 2007
10 Added ZLF645, Windows Vista-
32, and USB Smart Cable firmware compatibility information. Put contents into the latest template. Changed ZiLOG to Zilog
All
USB Smart Cable
User Manual
UM018112-0908 Table of Contents
iii
Table of Contents
USB Smart Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Supported Host Environments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installing the USB Smart Cable and Driver . . . . . . . . . . . . . . . . . . . 3
Windows Vista-32/64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Windows 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Windows 98 SE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connecting to the Target Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Power-On Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
USB Smart Cable Not Recognized . . . . . . . . . . . . . . . . . . . . . . 7
Host Does Not Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Customer Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
USB Smart Cable
User Manual
UM018112-0908 USB Smart Cable
1
USB Smart Cable
Zilog’s USB Smart Cable, ZUSBSC0100ZACG, allows you to connect ZLF645, Z8 Encore!
®
, Z8 Encore! XP®, ZNEO®, or eZ80Acclaim!® development board to a high-speed or full-speed USB port on Zilog Developer Studio II (ZDS II) host system.
This user manual provides instructions for installing USB Smart Cable hardware and the associated drivers. When the USB Smart Cable is con­nected and the driver installed, you can proceed with debugging as described in the development kit documentation.
Kit Contents
The kit contents for the USB Smart Cable include:
USB Smart Cable
Six-conductor ribbon cable
User manual
Supported Host Environments
The supported host environments are:
A host PC with ZDS II v4.9.0 or later version for Z8 Encore! and eZ80Acclaim!, or ZDS II v4.10.0 for ZNEO, or ZDS II v4.11.0 for ZLF645. For ZDS II host system requirements refer to the develop­ment kit quick start guide.
One USB high-speed or full-speed port on the host chassis or a pow­ered Hub.
USB Smart Cable
User Manual
UM018112-0908 USB Smart Cable
2
The USB Smart Cable cannot operate properly on an unpowered Hub (that is, a Hub without a separate AC adapter).
Windows NT hosts are not supported by the USB Smart Cable.
Table 1. Supported Target Environments
Table 2. USB Smart Cable Firmware Compatibility
Development Board
System Clock Power Supply Current
Minimum Maximum Minimum Maximum
Z8 Encore!
®
,
Z8 Encore! XP
®
,
ZLF645
32 kHz 20 MHz 2.7 V 3.6 V 2 mA
ZNEO
®
10 kHz 20 MHz 2.7 V 3.6 V 2 mA
eZ80Acclaim!
®
5 MHz 50 MHz 3.0 V 3.6 V 2 mA
CPU Family Firmware
Z8 Encore!
®
, Z8 Encore! XP®, ZNEO®, eZ80Acclaim!® 1.6
ZLF645 1.7
Z8 Encore!
®
, Z8 Encore! XP®, ZNEO®, eZ80Acclaim!®,
ZLF645
1.8
Note:
USB Smart Cable
User Manual
UM018112-0908 USB Smart Cable
3
Installing the USB Smart Cable and Driver
Before connecting the USB Smart Cable to your system, Windows loads the appropriate driver from the ZDS II installation directory or CD-ROM. You can download ZDS II software for a specific device family at
www.zilog.com
. Alternatively, if you have an applicable Zilog develop­ment tool, use the CD-ROM provided. The installation procedure depends on your Windows operating system version.
Zilog no longer includes CD-ROMs with USB Smart Cable kits built August 2006 or later.
Windows Vista-32/64
1. Connect the USB Smart Cable to the host PC. The Found New
Hardware dialog box is displayed.
2. Select Locate and install driver software (Recommended). The
Driver Software Installation window is displayed, and then the Found New Hardware-USB Smart Cable dialog box is displayed.
3. Select I don’t have the disc. Show me other options.
4. Select Browse my computer for driver software (Advanced).
5. Browse to one of the following driver directory:
For 32-bit Vista: <ZDS II Installation Directory>
\device drivers\USB\x32
<ZDS II Installation CD>\device drivers\USB\x32
For 64-bit Vista: <ZDS II Installation Directory>
\device drivers\USB\x64
<ZDS II Installation CD>\device drivers\USB\x64
Note:
USB Smart Cable
User Manual
UM018112-0908 USB Smart Cable
4
The Windows Security dialog box is displayed.
6. Select Install this driver software anyway.
7. When the software has been installed, click Closed.
Windows XP
1. Connect the USB Smart Cable to the host PC for the first time. The
Found New Hardware Wizard should activate automatically.
2. In the Wizard, select Install from a list or specific location
(Advanced); then click Next.
If the Windows Logo testing dialog appears, select Continue Anyway.
3. Select Search for the best driver in these locations and Include this
location in search.
4. Browse one of the following to the driver directory:
<ZDS II Installation Directory>
\device drivers\USB\x32
<ZDS II Installation CD>\Device Drivers\USB\x32
5. Click Next, and then click Next again after the appropriate driver is
found.
6. Click Finish to complete the installation.
Windows 2000
1. Connect the USB Smart Cable to the host PC for the first time. The
Found New Hardware Wizard should activate automatically.
2. In the Wizard, click Next.
3. Select Search for a suitable driver for my device (Recommended);
then click Next.
Note:
USB Smart Cable
User Manual
UM018112-0908 USB Smart Cable
5
4. Select Specify a location; then click Next.
5. Browse to one of the following driver directory:
<ZDS II Installation Directory>
\device drivers\USB\x32
<ZDS II Installation CD>\Device Drivers\USB\x32
6. Click OK, and then click Next after the appropriate driver is found.
7. Click Finish to complete the installation.
Windows 98 SE
1. Connect the USB Smart Cable to the host PC. The Found New Hard-
ware Wizard should activate automatically.
2. In the Found New Hardware Wizard, click Next.
3. Select Search for the best driver for your device (Recommended).
Click Next.
4. Select Specify a location. Browse one of the following to the driver
directory:
<ZDS II Installation Directory> \device drivers\USB\x32 <ZDS II Installation CD>\Device Drivers\USB\x32
5. Click Next, and then click Next again after the appropriate driver is
found.
6. Click Finish to complete the installation.
USB Smart Cable
User Manual
UM018112-0908 USB Smart Cable
6
Connecting to the Target Board
Power-On Sequence
Follow the steps below before connecting to target:
1. Connect the USB Smart Cable to the Host PC.
2. Connect the USB Smart Cable six-pin connector to the target board.
3. Apply power to the target board.
If the target is not connected properly, remove the USB Smart Cable from the host PC and repeat the above steps. If the connection issues are still there, see Troubleshooting Tips on page 7.
Attach one end of the six-conductor ribbon cable to the Smart Cable six­pin DBG connector (see Figure 1). Attach the free end of the ribbon cable to the connector on the target board. Ensure that pin 1 on the ribbon cable (indicated by the dark stripe) is aligned with pin 1 on the target connector. For further information on connecting the USB Smart Cable to your target board, refer to either eZ80Acclaim! Design for Debug Technical Note (TN0035) or Z8 Encore!
®
Design for Debug Technical Note (TN0036).
Figure 1. Connecting the Six-Conductor Ribbon Cable to the USB Smart Cable
USB Smart Cable
User Manual
UM018112-0908 USB Smart Cable
7
Troubleshooting Tips
If a hardware failure is suspected, contact a local Zilog representative for assistance. Before submitting a problem report to Zilog Customer Sup­port, follow the instructions in this section.
USB Smart Cable Not Recognized
Disconnect all other USB devices (including keyboard and mouse if you can use PS2 ports instead). Ensure that USB Smart Cable is plugged in directly with no intervening Hub. If this corrects the issue, reconnect devices one at a time to isolate the conflicting device.
Host Does Not Boot
Systems with one or more USB devices connected may not boot properly after you connect the USB Smart Cable. This issue is being investigated. The workaround is to connect the USB Smart Cable, after the system starts.
USB Smart Cable
User Manual
UM018112-0908
8
Customer Support
For answers to technical questions about the product, documentation, or any other issues with Zilog’s offerings, visit Zilog’s Knowledge Base at
http://www.zilog.com/kb
.
For any comments, detail technical questions, or reporting problems, visit Zilog’s Technical Support at http://support.zilog.com
.
USB Smart Cable
User Manual
UM018112-0908
9
DO NOT USE IN LIFE SUPPORT
LIFE SUPPORT POLICY
ZILOG'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF ZILOG CORPORATION.
As used herein
Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.
Document Disclaimer
©2008 by Zilog, Inc. All rights reserved. Information in this publication concerning the devices, applications, or technology described is intended to suggest possible uses and may be superseded. ZILOG, INC. DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION, DEVICES, OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT. ZILOG ALSO DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT RELATED IN ANY MANNER TO USE OF INFORMATION, DEVICES, OR TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering.
Z8 Encore!, Z8 Encore! XP, eZ80Acclaim, and ZNEO are registered trademarks of Zilog, Inc. All other product or service names are the property of their respective owners.
Warning: