
ZDI232ZPAK2ZPK
ZPAK II Debug Interface Module
UM016301-1003
User Manual
Introduction
This document describes how to setup and use the ZiLOG ZPAK II Debug Interface Module with your ZiLOG development kit. The ZPAK II module enables a development PC
running ZDS II to communicate with a ZiLOG development kit. It also provides an Ethernet interface to the development PC.
The kit includes:
ZPAK II module
•
•
DB9-to-ID10 serial cable
•
Keyed 40-conductor ribbon cable
•
Target Interface Module (TIM)
•
User Manual
•
CD-ROM with ZDS II software and additional documentation
Installing and Configuring ZPAK II
The ZPAK II module features an Ethernet interface and an RS-232 console port. Slight
modifications to your PC’s network configuration may be required for first-time use. Follow the steps in this section to install and configure the ZPAK II module. See Figures 1
and 2.
5 VDC 9 VDC
Development
Platform
Development
ZPAK II
ZDITIM
Development PC
Ethernet
RJ-45
Hub
RJ-45
RS-232
Figure 1. Hardware Setup using an Ethernet Hub
ZiLOG Worldwide Headquarters • 532 Race Street • San Jose, CA 95126
Telephone: 408.558.8500 • Fax: 408.558.8300 •
www.zilog.com
¤
eZ80
Kit
eZ80
Development
Module
¤

ZDI232ZPAK2ZPK
ZiLOG ZPAK II Debug Interface Module
Page 2
Development PC
Crossover CAT5
RS-232
5 VDC 9 VDC
Development
Development
ZPAK II
ZDITIM
eZ80
Platform
eZ80
Kit
Development
Module
Module
¤
eZ80
¤
Figure 2. Hardware Setup using a Crossover Ethernet Cable
1. Set up the target development kit as described in its quick start guide (supplied on the
CD-ROM).
2. Connect the Target Interface Module (TIM) to the ZPAK II module using the keyed
40-conductor ribbon cable.
3. Connect the TIM to the ZDI port on the target development board. Align pin 1 of the
TIM to pin 1 of the development board’s ZDI socket.
5. If using an Ethernet hub, connect an Ethernet patch cable from a free port on the
Ethernet hub to the Ethernet port on the ZPAK II module. Connect the PC’s Ethernet
port to the same hub.
If connecting the development PC directly to the ZPAK II module, connect a crossover Ethernet cable from the PC to the ZPAK II module.
6. Connect the serial COM port on the PC to the console port on the ZPAK II module via
the supplied serial cable and the 10-pin adapter cable. (You may need to reconfigure
the ZPAK II module IP address for your networking environment.)
7. Connect the 5 VDC power supply to the ZPAK II module.
Configure the Hardware
The default IP address and subnet mask of the ZPAK II module are 192.168.1.50 and
255.255.255.0, respectively. To enable communication between the PC and the ZPAK II
module, you must either change the PC’ s Ethernet settings to match those of the module or
vice versa.
If using the PC in a non-networked configuration, set the PC’s IP address to 192.168.1.21
and its subnet mask to 255.255.255.0. See “"Changing the PC’s Settings to Match the
ZPAK II Module"” on page 3 for instructions.
UM016301-1003 Configure the Hardware

ZDI232ZPAK2ZPK
ZiLOG ZPAK II Debug Interface Module
Page 3
If working in a networked environment, set the ZPAK II module IP address and subnet
mask to match the existing network setup. See “"Changing ZPAK II Module Settings to
Match the PC"” for instructions.
Changing the PC’s Settings to Match the ZPAK II Module
The following instructions are for the MS W indows XP platform. If your Windows operating system is different, please refer to your MS Windows OS online help for details.
1. Open the Windows Control Panel and double-click the Network and Internet
Connections icon. The Network Connections dialog box appears (Figure 3).
Figure 3. The Network Dialog
UM016301-1003 Configure the Hardware