Duct Cover Extension
Z1C-00SU
For use with Surface range hood
customer service
1.888.880.8368
Mounting the duct cover Pag. 3
Fixation des cheminees Pag. 4
Fijación de las chimeneas Pag. 5
Fissaggio dei camini Pag. 6
www.zephyronline.com
DUCT COVER EXTENSION SPECIFICATION
12-9/16"
Min 43" - Max 79"
- 2 -
MOUNTING THE DUCT COVER
1. Install the electrical wiring and test hood for
functions prior to installing the duct covers.
2. If using hood in air recirculating mode make sure
to install the air diverter plate prior to mounting
the duct covers. See the manual included with
the recirculating kit for more instructions.
4. Secure duct cover bracket to top of wall just below
the ceiling using (2) screws provided, observing
the distance shown in Fig. 1
5. Place ducting from ceiling over the collar on top
of the hood and secure using aluminum duct
tape. See Fig.2
6. Insert top duct cover into bottom duct cover.
7.
Place duct covers over hood body. Fig.3. Slide duct
covers towards the wall and make
sure the lip of the bottom duct
cover slides under the metal lip on
top of the hood body.Fig. 4
8. Extend top duct cover up and
secure to the duct cover bracket
using (2) screws. See Fig. 5
Installation - Mounting the Duct Cover
9. Secure bottom duct cover to the
hood using the (2) screws provided. Fig.6
- 3 -