Zephyr XXL Owner's Manual

Corporate Office
200, 11246 - 163 St. Edmonton AB T5M 1Y6
Phone: 780-930-1100 Fax: 780-930-1125
Toll Free: 1-877-528-2010
AIR PURIFIER
E356005
Owners Manual
Model: XXL
10
Maintenance
WARNING
1. This sign indicates that any wrongful usage of the unit
may lead to electric shock, serious injuries and death.
NOTE
2. This Sign indicates that any wrongful usage of the unit may lead to injury or damage to personal belongings.
NOTE
3. Never clean the filters with water to avoid
replacement.
Filter Replacement
The standard service life for the replacement filter (HEPA,
Activated Carbon and Photo Catalyst cartridge) is as
follows: 1 year - in smoking homes or homes with pets
2 years - in all other applications
The Pre-filter is recommended to be cleaned using a vacu-
um cleaner every 2 - 3 months.
Contact your authorized Zephyr retailer for purchase of re-
placement filters.
Troubleshooting
Failure Checklist
Will not operate
Check that the power plug is properly inserted into the outlet
* Check that the battery is still usable
Remote Control is not operational * The battery is installed properly
* The units receiver is facing the remote control
Unable to remove odour
* The air intake may be blocked. Clean both the air intake and ducts. * If the filters are too dirty, clean the pre-filter and replace the replacement filter cartridge.
Unable to remove dust in the air
Loud operational noise level
5
When using electrical appliances, basic safety precautions should always be followed, including the following:
WARNING -To reduce the risk of electrical shock, fire or
injury to persons
Use only as described in this manual. Use only a 120-volt outlet with a polarized receptacle. The Zephyr has a polarized plug (one blade is wider than
the other is), this plug will fit in a polarized outlet only one way. Initially, if the plug does not fit into the outlet, reverse it. If it still does not fit, contact a qualified
electrician or service person. Do not use the air purifier if the power cord or plug is
damaged or the connection to the wall outlet is loose.
When removing the power plug, always hold the plug and
never pull by the cord. Do not handle plug or appliance with wet hands. Electrical shock and/or fire from short
circuit may occur.
Remove the power plug from the wall outlet before cleaning
the unit and when not using the unit. Turn off all controls before unplugging.
If the power cord is damaged, it must be replaced by the
manufacturer, its service agent, Zephyr authorized service or similarly qualified person.
Do not insert fingers or foreign objects into the intake or air
outlet.
The batteries must be removed from the remote control
before disposal, and the batteries must be disposed of safe­ly.
Keep hair, loose clothing, fingers and all parts of body
always from openings and moving parts.
Do not use appliance in an enclosed space where oxygen,
flammable, explosive or toxic vapors are given off by oil base paint, paint thinner, some mothproofing substances, or in an area where flammable dust is present.
Important Safety Precautions
6
Cautions Concerning Operation
Do not block the intake and air outlet. Do not use the unit near or on hot objects, such as range or
where it may come into contact with steam.
Do not use the unit on its side. Do not operate the unit without filters. Do not wash and reuse HEPA, Activated Carbon or Photo
Catalyst filters
Do not clean outside with paint thinner or any chemicals.
The unit surface may become damaged or may cause fire.
Components and Control Panel
1
Congratulations on the purchase of your Zephyr air purification system. The Zephyr is a 7 stage filtration system equipped with high efficiency filters. To become familiar with your new product, please read the manual carefully and retain this booklet for future reference.
Contents
Contents………………………………………………………… Wiring Diagram ……………………………………………….. Consumer Limited Warranty ………………………………… How it Works …………………………………………………... Functions and Features ………………………………………. Specifications ………………………………………………….. Important Safety Precautions ………………………………... Cautions Concerning Operation ……………………………. Components and Control Panel……………………………... Operation (Main Unit) ………………………………………… Operation (Remote Control)…………………………………. Placement ………………………………………………………. Filter Installation ………………………………………………. Maintenance …………………………………………………… Troubleshooting ……………………………………………….
1 1 2 3 3 - 4 4 5 6 6 7 7 - 8 9 9 10 10
Wiring Diagram
8
2. Auto Setting The Auto function button is located on the remote. By
touching it once, it will turn the Zephyr to its auto setting and the will illuminate on the display panel. Sensors will detect and measure dust and VOC levels in the air. The VOC on the LED display indicates VOC levels from 0-6. As each two indicators increase so will the Zephyrs fan speed to eliminate the contaminants from the air. The sign on the LED indicates dust levels in the air from 0-6. As dust levels increase so will the fan speed for every two bars. The sensors are only activated when the system is set on the auto setting.
3. Timer Setting
Press the Timer button once and use the “+” or “- buttons to select the desired time. To set the time simply touch the Timer button again and the selected time will stop flashing and begin countdown.
4. Sleep Mode Sleep mode dims the display panel and lowers the fan
speed so it is nearly silent. By touching the Sleep button once, it will activate the function. To cancel, simply touch again.
5. The Power, Fan Speed and UV/Plasma Generator buttons work the same as on the control panel.
7
Method of Operation
1. Plug Zephyr in Plug the Zephyr in to the nearest electrical outlet, once the red power indicator lights up on the control panel the unit is ready for operation.
2. On/Off
Touch the power sign on the control panel. The LED
display will illuminate, the system is turned on. To turn the system off, just simply touch the power sign again.
3. Fan Speed Adjustment
To adjust fan speed touch the fan sign to increase
the fan speed. The LED screen will indicate one blue fan for low speed, two for medium, and three for high speed.
4. UV Light & Plasma Generator
To turn the UV Light and Plasma Generator on, touch
sign. The indicator light will illuminate on the control panel. To turn them off simply touch the sign again and the indicator light will turn off.
5. Timer Setting
To enable the timer function, touch the timer sign
once and the time will begin flashing on the LED screen. By continuing to touch the timer button, the time will increase in 30 minute intervals up to 8 hours. Choose the desired setting and after 3 seconds the time will set and begin its countdown.
Operation (Main Unit)
Operation (Remote Control)
1. Child Lock feature By touching the lock button, the control panel but
tons will be disabled and the lock indicator will illuminate. To reverse the option, simply touch the lock button again or power the unit down.
4
Plasma Generator:
Produces 8 million negative ions per second which helps to re­duce airborne particulates, freshen indoor air as well as hav­ing many positive health benefits.
Auto Setting feature:
Through the use of both a dust sensor and VOC sensor, the
Zephyr will self regulate it’s fan speed based on surrounding
air quality detected.
Time Setting:
Time set feature allows you to set the timer for up to 8 hours. Once the timer counts down to zero the Zephyr will turn off.
Specifications
Model
Zephyr - XXL
Power Requirement
110V, 60Hz, 85W
Rated Air Flow (CFM)
H: 455cfm, M: 250cfm, L: 150cfm
High: 773 m3/hr
Applicable Volume (m3/hr)
Medium: 424 m3/hr
Low: 254m3/hr
Noise Level
<45dB
Dimensions (cm)
H: 66.5cm, W: 26cm, L: 48cm
Weight (kg)
12.5kg
3
How it Works
The air purifier functions as an air cleaner by helping to disinfect airborne microorganisms and removing particulates from the air. The centrifugal fans of the Zephyr draw air through the front and side panels (Intake) located on the front portion of the unit. Then the air passes through the Pre-filter, HEPA filter, Activated Carbon Filter, the UV-Photo Catalyst sterilization chamber, Vitamin C filter and Plasma Generator. The purified air is then released through the outlet on the top of the unit.
Functions and Features
Pre Filter:
Designed to stop and remove larger particles from the air. No replacement necessary, recommended cleaning once every 2 months by vacuuming.
HEPA filter:
Removes 99.97% of airborne particulates such as dust, pollen and other biological contaminants down to 0.3 microns.
Activated Carbon Filter:
Absorbs harmful odors and gases, eliminating them from the air.
Photo Catalyst filter:
Decomposes and eliminates Volatile Organic Compounds
(VOC’s) such as cigarette smoke, benzene, formaldehyde,
ethanol, ammonia, etc. and eliminating them from the air.
UV Sterilization Lights:
Two (2) 254nm UV lights are designed to kill viruses, bacteria, mold spores and micro-organisms down to 0.03 microns and eliminating them from the air.
Vitamin C filter:
Releases vitamin C into the air which has many benefits including strengthening the immune system, preventing illness, and improvements to overall health.
2
Zephyr gives you the following limited warranty for this product only if it was originally purchased from an authorized Zephyr Dealer.
Zephyr warrants that this product is free, under normal use and maintenance, from any defects in material and workmanship. If any such defects should be found in this product within the applicable warranty period. Zephyr shall, at this option, repair or replace the product as specified herein.
Zephyr will repair or replace, free of charge, to the original purchaser, any of the parts listed herein (Motor, Odor Sensor, Dust Sensor, UV lights, Plasma Generator) that is found to be defective in material or workmanship within (5) five years of the date of purchase. The warranty on the remote control is (5) five years from the date of purchase. This limited warranty does not cover the replacement of expendable or consumable parts such as filters and other parts subject to normal wear unless they are defective in material or workmanship.
This warranty shall not apply to:
(A) Any defects caused or repairs required as a result of
abusive operation, negligence, accident, improper installation or inappropriate use as outlined in the operation manual.
(B) Any product tampered with, modified, adjusted or repaired
by any party other than an Authorized Zephyr Service Center, or authorized Zephyr Dealer.
(C) Damaged caused or repairs required as a result of the use
with items not specified or approved by Zephyr.
(D) Any damage caused by external or environmental
conditions, including but not limited to the use of voltage other than indicated on the product.
Zephyr’s limited warranty is valid only if you retain proof of
purchase from Zephyr or an authorized Zephyr Dealer.
In the event that the Zephyr product must be shipped to the Zephyr Dealer or Service Center for repair, any and all shipping costs will be at the owners expense.
Limited Warranty
9
Placement
Filter Installation
Loading...