Model DBI-600A
Page 1
For use with these Downdraft Ventilators:
ZEPHYR Models: DLI-E30ASX, DLI-E36ASX
(Purchase Downdraft Ventilator separately.)
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit on ly in the manner intended by the ma nufacturer.
If you have questions, contact the manufacturer.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a t ag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Suffic ient air is needed for proper c ombustion and exhausti ng
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
9. Loose-fitting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/
elements on cooktop.
10. Children should not be left alone or unattended in the area
where this appliance is in use.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWINGa:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi-
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
a
Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers , keep drywall spray, constru ction dust, etc. off p ower
unit.
4. Clean filters and grease-laden surfaces frequently.
5. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
6. Please read specification label on product for further
information and requirements.
7. To reduce the risk of fire and electric shock, install this blower
only with downdraft ventilator models shown below. Other
downdraf t ventilator models cannot b e substituted. (Downdraf t
ventilators sold separately).
ZEPHYR Models
Save this manual for Electrical
Inspector and Homeowner to use.
DLI-E30ASX, DLI-E36ASX
INSTALLER:
CONTENTS
These parts are included with your DBI-600A blower:
2 - blower mounting legs*
1 - Parts Bag containing:
(4) wood screws #10 x .50*
(4) blower mount brackets
(1) strain relief bushing
(8) screws #10 x .38
(8) nuts #10
* For use when mounting DBI-600A blower directly to Down-
draft housing. (See Downdraft instruction manual.)
PLAN THE INSTALLATION
Model DBI-600A
Page 2
(4) MOUNTING
BRACKETS
attached with
1/4-20 X .50
HEX HEAD
SCREWS
(6) MOUNTING
BRACKET
LOCATIONS
If you choose to mount the blower directly to the Downdraft
housing: Remove the inlet cover (taped in place for shipping)
and discard inlet cover. Refer to installation instructions in the
Downdraft manual.
If you choose to mount the blower in a remote location, (such
as the cabinet back, cabinet side, or floor joists) - follow the
instructions below.
INSTALL BLOWER
IN REMOTE LOCATION
NOTE: THE BLOWER MUST BE INSTALLED WITHIN 4-FEET OF
THE DOWNDRAFT’S ELECTRICAL PANEL. The Electrical Panel
can be mounted directly to the Downdraft housing - or mounted
in a remote location (always within 4-feet of the Flex Blower).
BLOWER
INLET
COVER
INLET
(from downdraft)
1. Position inlet cover over blower wheel. Securely attach the
inlet cover to the blower with 8 screws and 8 nuts from parts
bag. Note that inlet cover is taped to blower for shipping. This
tape may be removed.
2. Determine how the 8” round INLET and OUTLET ductwork
will connect to the blower.
OUTLET
(to roof cap
or wall cap)
3. Remove the necessary 1/4-20 x .50 hex head screws and
attach 4 MOUNTING BRACKETS to the blower - using 4 of
the 6 POSSIBLE BRACKET MOUNTING LOCATIONS.
MOUNTING SCREWS
(not included)
8-IN.
ROUND
8-IN.
ROUND
DUCT
(from
downdraft)
4. Mount blower to back of cabinet, floor joist, or adequate
framework (constructed by installer) with appropriate
MOUNTING SCREWS (not included).
5. Connect 8” ROUND DUCT from Downdraft housing to blower
inlet and from blower outlet to roof or wall cap.
For best performance: Choose the ducting option which allows
the shortest length of ductwork and a minimum number of
elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
6. Use strain relief bushing (provided) to attach blower wiring to
wiring box on Downdraft’s electrical panel and make wiring
connections. (See Downdraft manual for instructions.)
DUCT
(to roof cap
or wall cap)
99046136 / 99045244