Zebra RP4T Passive RFID Printer P4T/RP4T Quick Start Guide (en)

Quick Start Guide
P4T/RP4T
Introduction
Getting Started
Printer
Introduction
Thank you for choosing one of our Zebra P4T Series Mobile Printers. The P4T Series con-
sists of two models. The P4T can print on direct thermal or thermal transfer media. The RP4T can print on direct or thermal transfer media and also encode special RFID media.
Because these printers are made by Zebra Technologies you can be assured of world-class sup­port for all of your bar code print­ers, software, and supplies.
This document provides an easy reference for operating and main­taining either the P4T or the RP4T Mo­bile Printer.
Complete and current documentation for these printers is provided by the P4T/RP4T User Guide available on the Internet at:
www.zebra.com/manuals.
8
7
9
6
P4T/RP4T Overview
5
4
3
2
1
10
Troubleshooting
Contact Us
Always refer to the Important
Safety Information data sheet shipped with each printer and the Technical Bulletin shipped with each battery pack. These documents detail procedures to ensure maximum reliability and safety while using this printer.
1. Platen Roller
2. Bar Sensor
3. Media Support
4. RFID Reader/Encoder (RP4T only)
5. Printhead
6. Ribbon Cartridge Cover
7. Control Panel
8. Ribbon Cartridge Cover Latch
9. Media Cover Latch
10. Media Support Disks
11. Label Peeler
12. Media Cover
13. External Media Access (optional)
14. Battery
15. Battery Charging Receptacle
16. RS232 Communications Port
17. USB Port
15
11
17
16
12
13
QSG-P4T-002 Rev. D
14
© ZIH Corp. 2013
1
Quick Start Guide
P4T/RP4T
Charge the Battery Pack
Introduction
Getting Started
Printer
Battery packs are shipped uncharged. Remove
protective shrink-wrap and labels from new battery packs and allow them to charge completely prior to initial use.
The printer cannot be used while charging with the
single charger.
Battery Charging Receptacle
LI72 Single Battery Charger
Battery Pack
The printer may be used while charging the battery
pack with the AC adapter. However, prolonged use of the printer while charging will greatly increase charge times.
AC Adapter
Open the
protective cover
for access to
the charger
receptacle
Troubleshooting
Contact Us
Using the Single Battery Charger
If the Battery Pack is new, remove its protective wrapping and discard the warning label covering the battery contacts. If you are charging a previously used Battery Pack, remove it from the print­er.
Insert the plug from the Charger cable into the Battery Charging Receptacle. Plug the Charger into an appropriate AC outlet.
The light on the front of the charger will indicate the battery pack’s charge status.
Using the AC Adapter
If the Battery Pack is new, remove its protective wrapping and discard the warning label covering the battery contacts. Install the Battery Pack in the printer.
Insert the plug from the AC Adapter cable into the Battery Charg­ing Receptacle. Plug the Adapter into an AC outlet.
Consult the P4T/RP4T User’s Guide available at
www.zebra.com/manuals for complete information on charging
batteries on P4T Series printers.
Section Continues
2
Quick Start Guide
Fault
Fast Charg e
Fault
Fast Charg e
Fault
Fast Charg e
Ready
Power
Full Charg e
Ready
Full Charg e
Ready
Full Charg e
Full Charg e
Fault
Fast Charg e
Ready
P4T/RP4T
UCLI72-4 Quad Charger
The UCLI72-4 uad Charger is an optional accessory kit allowing simultaneous charging of up to four battery packs.
Introduction
Getting Started
Printer
1. Slide Battery Pack into a Char­ger bay
2. Rock Bat­tery Pack into place
Power Supply
The UCLI72-4 Quad Charger is designed to charge up to four battery packs simultaneously. Charging time is as follows:
Battery Status Charging
Time
80% charged 2.5 Hrs. Full charge 5 Hrs.
Plug a battery pack into any one of the four charg­ing bays as shown opposite, noting the orientation of the battery pack. Slide the battery pack into the charging bay until it stops. Then rock the battery pack back until it snaps into place. The amber indi­cator directly under the battery pack being charged will turn on if the battery pack is properly inserted.
The indicators under each battery pack will allow you to monitor the charging process per the table below:
Amber Green
Battery Status
Troubleshooting
Contact Us
On O Charging
On Flashing
Amber Indicator
Green Indicator
Charger Bay
Power Indicator
O On
Flashing O Faulty battery
For more information refer to the instructions included with the UCLI72-4 Quad Charger, or to the more detailed discussion of the quad
charger in the P4T/RP4T User Guide.
The UCLI72-4 Quad Charger has a safety feature which stops charging after six hours regardless of the battery pack’s charge state.
80% charged (O.K. to use)
Completely Charged
pack
Section Continues
3
Quick Start Guide
P4T/RP4T
Install the Battery Pack
Always use Zebra approved battery packs and media for maximum performance
and superior printing results. P4T Series printers will not operate with non-Zebra batteries.
Introduction
Getting Started
Printer
Troubleshooting
Contact Us
Insert a fully charged battery pack
into the bottom of the printer as
shown.
Press battery pack until it clicks
into place
Remove the battery pack by pressing on the latch and rotating the battery pack out of the bottom of the printer.
Battery Pack
Section Continues
4
Quick Start Guide
P4T/RP4T
Introduction
Getting Started
Load the Media
Press down on the Media Cover Latch Lever
1. Open the Media Cover
Media cover opens
Pull Media Supports
apart where shown.
Load Media Roll
Note direction media pulls o the roll. Always ensure you are using the correct me­dia. Use RFID media only in RP4T printers.
Printer
Troubleshooting
Contact Us
Pull Media out of the Printer. Use alignment marks on the cover to ensure alignment.
Close Media Cover
2. Load the Media Roll
Peeler Assembly.
Peeler Bar.
3. Feed the leader over
the peeler bar and into
the printer.
4. Press down on Peeler Assembly where shown and slide the media until it emerges .
1. Remove enough labels from the me­dia roll to create a 4” [100 mm] leader.
2. Align the edge of the leader with the index marks on the top cover to ensure it will pass through the peeler without wrinkling.
3. Close the Media Cover
4. Insert Media into Peeler
Optional Step for label stock only