INSTALLATION
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or
electric hotplate and can be used either in the extraction mode (ducted to the outside) or
in the recirculation mode (internal recycling).
Safety warnings
• Before commencing the installation, consideration should be given to the difficulties
to be found during installation and to the bulky weight of the hood. The installation
work must be undertaken by a qualified and competent person in conformity to the
rules concerning the evacuation of contaminated air. The manufacturer disclaims all
liability for any damage or injury caused as a result of not following the instructions
for installation contained in the following text.
• When used in the extraction mode the cooker hood ducting must not be connected to
a flue which is used for exhausting fumes from appliances supplied with energy other
than electric such as a central heating flue or water heating flue.
• When istalled, the hood must be positioned at least 65 cm above a cooking appliance.
• Never do flambé cooking under this cooker hood.
• Never leave frying pans unattended during use as overheated fats and oils may catch
fire.
• If the room where the cooker hood is to be used contains a fuel burning appliance
such as a central heating boiler then this must be of the room sealed or balanced flue
type. If other types of flue or appliance are fitted ensure that there is an adequate
supply of air into the room. When the cooker hood is used in conjunction with other
appliances supplied with energy other than electric, the negative pressure in the room
must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the
cooker hood.
Components
The hood comprises the following (fig.1):
• No.1 canopy
controls, lighting and ventilator
unit
• No.1 telescopic chimney,
comprising:
No.1 upper chimney element
No.1 lower chimney element
• No.2 directional grills G
• No.1 reduction flange Ø 150-120
A
• No.1 valve V (optional )
• No.1 recirculation spigot
• No.2 additional side recirculation
spigots
• No.1 additional recirculation
spigot
• No.1 bag containing:
No.2 brackets 2 to fix the
chimney, screws, rawl plugs and
documents.
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
C complete with
P1
P
S
I
R
Fig. 1
11GB
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
Installation instructions
For easy installation, proceed as follows:
• Fix the wall brackets
• Fix the canopy
• Electrical connection and working test
• Ducting or Recirculation fitting
• Fix the telescopic chimney
Fitting the wall brackets
Please refer to (fig.2):
• Draw a vertical line on the wall, from the centre
of the cooking appliance up to the ceiling,
using a marking pen. This is to ensure the
correct vertical alignment of the various parts.
• Fixing the wall brackets item
a) Place one of the brackets
approximately 1 or 2 mm from the ceiling or
from the top limit, aligning its centre (slot) with
the vertical line.
b) Mark the centres of two keyholes in the bracket
on the wall.
c) Rest the other bracket 2 against the wall,
aligning it with the vertical line, at a distance
X measured as shown in fig. 2 equal to the
height of the upper chimney element S
supplied with the hood. The position X may
vary, according to the various sizes of upper
chimney element available.
d) Mark the centres of the keyholes in the bracket
on the wall.
• Drilling fixing holes item 1:
a) Mark a point on the vertical line at a distance
from the cooking appliances of:
d =982 min.
b) At the point marked, draw a horizontal line
parallel to the cooking appliances.
c) Drill two holes in the wall
bit (fig.2), and insert the rawl plugs and screws
into the holes 1 (4.2 x 44.4 screws). Fix the
screws, leaving a space of 5-6 mm required
to hook up the canopy. Small adjustments can
be made using the hood adjustment screws
(see Fitting the canopy). The hood should have
a maximum excursion of 20 mm.
2 against the wall
1 using an 8 mm drill
2:
2
232
260
20
Fig. 2
11
12
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○