lowest overall cost of ownership. Interchangeable probes
and cables reduce down-time
and keeps the Pro Plus ready
whenever and wherever you
are - field or lab.
if complexity is the problem....
ease of use is the solution;,
productivity is the impact.
Ammonium*** Sensor Type Ion Selective Electrode
Range 0 to 200 mg/L-N, 0 to 40°C
Accuracy ±10% of reading or 2 mg/L-N,
whichever is greater
Resolution 0.1 mg/L
Units mg/L-N, mV
Calibration 1, 2, or 3 point (user selectable)
Depth 17-meters submersion
Nitrate*** Sensor Type Ion Selective Electrode
Range 0 to 200 mg/L-N, 0 to 40°C
Accuracy ±10% of reading or 2 mg/L-N,
whichever is greater
Resolution 0.1 mg/L
Units mg/L-N, mV
Calibration 1, 2, or 3 point (user selectable)
Depth 17-meters submersion
Chloride*** Sensor Type Ion Selective Electrode
Range 0 to 1000 mg/L, 0 to 40°C
Accuracy ± 15% of reading or 5 mg/L,
whichever is greater
Resolution 0.1 mg/L
Units mg/L-Cl-, mV
Calibration 1, 2, or 3 point (user selectable)
Depth 17-meters submersion
Total Dissolved Solids Sensor Type Calculated from conductivity and
(TDS) temperature
Range 0 to 100 g/L
Cal constant range 0.30 to 1.00
(0.64 default)
Resolution 0.001, 0.01, 0.1g/L
Units kg/L, g/L
Barometer Sensor Type Piezoresistive
Range 375 to 825 mmHg
Accuracy ±3 mmHg within ±10°C from
calibration point
Resolution 0.1 mmHg
Units mmHg, inHg, mbar, psi, kPa, ATM
Calibration 1 point
(SYSTEM W/4-METER CABLE AND PROBES)
Dissolved Oxygen Sensor Type Polarographic or Galvanic
(%) Range 0 to 500%
Accuracy 0 to 200% ± 2% of reading or 2% air
saturation, whichever is greater
200% – 500% ± 6% of reading
Resolution 1% or 0.1% air saturation
(user selectable)
Calibration 1 point and zero
Dissolved Oxygen Sensor Type Polarographic or Galvanic
(mg/L) Range 0 to 50 mg/L
Accuracy 0 to 20 mg/L (±2% of the reading or
0.2 mg/L, whichever is greater)
20 to 50 mg/L (±6% of the reading)
Resolution 0.1 or 0.01 mg/L (user selectable); 0.1%
air saturation
Calibration 1 point and zero
Temperature Range --5 to 70°C
(Field rugged cables) Accuracy ±0.2°C
Resolution 0.1°C
Units °C, °F, K
Temperature Range --5 to 70°C
(Lab-grade)* Accuracy ±0.35°C
Resolution 0.1°C
Units °C, °F, K
Depth 4-meters submersion
Conductivity** Sensor Type Four electrode cell
Range 0 to 200 mS/cm
Accuracy ±0.5% of reading or 0.001 mS/cm,
whichever is greater (4-m cable)
±1% of reading or 0.001 mS/cm,
whichever is greater (20-m cable)
Resolution 0.001 mS/cm to 0.1 mS/cm (range
dependent)
Units µS, mS
Calibration 1 point
Salinity Sensor Type Calculated from conductivity and
temperature
Range 0 to 70 ppt
Accuracy ±1.0% of reading or 0.1 ppt,
whichever is greater
Resolution 0.01 ppt
Units ppt, PSU
Calibration 1 point
pH Sensor Type Glass Combination Electrode
Range 0 to 14 units
Accuracy ±0.1 units
Resolution 0.01 units
Units mV, pH units
Calibration 1, 2, 3, 4, 5, or 6 point (user selec
table); US, NIST or Custom Buffers
ORP Sensor Type Platinum button
Range --1999 to +1999 mV
Accuracy +/-20 mV in redox standards
Resolution 0.1 mV
Units mV
Calibration 1 point
(INSTRUMENT ONLY AT AMBIENT TEMPERATURE)
pH Range -2.60 to 16.60
Accuracy ±0.1 mV (0.01 pH units)
Resolution 0.1 mV (0.01 pH units)
ORP Range -1999 to +1999 mV
Accuracy ±0.5 mV
Resolution 0.01 mV
Conductivity Range 0.0 to 200 mS/cm
Accuracy ±0.3% FS ±1 digit for each range
Resolution 0.0001 mS/cm or 0.1 uS/cm to 0.1
mS/cm (range dependent)
Dissolved Oxygen Range 0.00 to 90 mg/L; 0 to 550%
Accuracy ±0.2% FS (550% air saturation)
±1 digit (with 1.25 PE membrane
at 10°C)
Resolution 0.01 mg/L; 0.1% air saturation
Temperature Range -10 to 100.00C
Accuracy ±0.1% FS ±1 digit
Resolution 0.1C
Units C, F, K
* Lab-grade cables include 605107, -108, -109, 605177, -178, -179
** Derived parameters can include resistivity, salinity, specific conductance, and total dissolved solids
*** ISE sensors for freshwater only
SPECIFICATIONS