The YOUNG Model 06206 Marine Wind Tracker is a compact wind speed and
direction display with advanced features relative wind angle and NMEA serial
I/O making it suitable for shipboard use.
FEATURES
• 3-digit wind speed display
• 3-digit maximum wind speed or wind direction display
• Multi-color wind direction display with variability
• Wind speed and direction alarms with delay
• RS-485/NMEA serial connections
• Calibrated 0-5 VDC outputs
• Display brightness control
• Compatible with YOUNG wind sensors & 4-20 mA inputs
PRECAUTIONS
• INDOOR USE ONLY unless placed in approved enclosure
• Operating temperature range 0-50°C (32-122°F), 0-95% RH
• Use only recommended power sources. 12-30 VDC, 3.5 W
• Disconnect power when connecting or servicing
• Alarm contact rating 24 VAC/30 VDC, 5 A resistive,
2 A inductive maximum
FACTORY DEFAULT SETTINGS
1. Wind speed display
2. Wind speed units indicator
3. Alarm status indicators
4. Data averaging indicator
5. Maximum wind speed or direction display
6. Wind direction and variability display
7. Brightness control (operate) or Enter key (setup)
8. Maximum Reset (operate) or Select (setup)
BACK PANEL
INPUT:
- Sensor Input Setting: "05" Wind Monitor
- Input selector switch position: "Down" (Sensor)
OPTIONS:
- Averaging: "No"
- Right hand display window: "Max Wind Speed"
- Alarms: "No"
OUTPUT:
- Voltage Outputs: 0-5Vdc=0-100m/s / 0-5Vdc = 0-360°
- NMEA Serial Output Rate: "FST"
IMPORTANT NOTE!:
Before connecting any external devices, verify the above
settings are compatible with your application. If different,
refer to the wiring diagrams in the back of the manual for
the correct settings.
Page 1 06206-90(G)
1. Power input coaxial jack (12-30 VDC)
2. Power input terminals (12-30 VDC)
3. Sensor or 4-20 mA inputs
4. Earth ground connection
5. RS-485 serial input/output
6. 0-5 VDC calibrated outputs
7. Alarm relay connections (Normally Open)
8. Input Selector Switch (Sensor or 4-20mA)
MOUNTING AND START-UP
1. For best visibility, place the Wind Tracker in a location free of
direct sunlight. Mount it using the attached bracket or remove
bracket for ush mounting to a bulkhead or panel cutout. Panel
cutout dimensions are given in the specications. An optional
rack mounting panel (Model 06280) and protective enclosure
(Model 06260) are available from your YOUNG supplier.
2. Connect cables to terminals according to wiring diagram.
Display Averaging (annunciator blinks)
dSP no Instantaneous data displayed
YES Average data displayed
PEr 030 Set averaging period in seconds (0-999).
Display will update at this interval.
Right Display Window Selection
dSP SPd Maximum wind speed
dir Wind Direction degrees
IMPORTANT NOTE! Please observe correct position of
back-panel Input Selector Switch according to wiring
diagram.
3. Connect GND terminal to suitable earth ground.
4. Insert power supply plug into power jack, plug power supply
into a suitable AC wall outlet or connect to suitable 12 to 30
VDC power source to terminals.
IMPORTANT NOTE! Do not connect two different power
sources to the Marine Wind Tracker at the same time.
5. When power is applied, the Wind Tracker will display rmware
version number then begin to display wind information as
follows:
• Wind speed
• Wind speed units
• Maximum wind speed or direction degrees
• Wind direction (single orange indicator)
• Direction variability (green indicators)
• Alarm status indicators (if selected)
• Data averaging indicator (if selected)
6. Observe display to conrm proper operation.
Wind Direction Alarm (annunciator blinks)
ALr no Direction alarm not armed
YES Direction alarm armed
ALr dir SELECT key sets direction alarm sector start.
ENTER key saves.
ALr SPn SELECT key sets direction alarm sector span.
ENTER key saves.
Wind Speed Alarm (annunciator blinks)
ALr no Speed alarm not armed
YES Speed alarm armed
ALr 000 Alarm set-point. SELECT key increments value.
ENTER key saves.
Alarm Delay Time
dLY 030 Alarm delay time in seconds (0-999). SELECT key
increments value. ENTER key saves.
Sound
Snd no No sound
YES Audible beep with alarm activations or average
update.
Wind Direction Voltage Output Scale
dir 360 0-360 degrees
540 0-540 degrees
CHANGING SETTINGS
Marine Wind Tracker parameters may be inspected or changed
in SETUP mode. Press and hold both ENTER and SELECT keys
for about 4 seconds. When SETUP mode is active, abbreviations
identify each function and available options as listed below. The
SELECT key changes options or values. The ENTER key saves
and moves to the next parameter.
Appearance of options depends on parameter settings. Some
options may be hidden.
DISPLAY SETUP FUNCTION
Input / Sensor Type
InP 03 Wind Sentry
04 Wind Monitor-Jr
05 Wind Monitor
SEr NMEA serial input
Ld2 Line Driver 4-20mA input (0-100 m/s)
Hd Wind Monitor HD
Ldi Line Driver 4-20mA input (0-50 m/s)
Wind Speed Units (annunciator blinks)
SPd unt SELECT key changes units. ENTER to save
NMEA Serial Output Rate
Out FSt 16 times per second
SLO Once per second
Test Functions
tSt no No test
YES Test
tSt ALr SELECT key closes alarm relays.
CAL 0.00 SELECT key alternates between 0.00 and
5.00 VDC output to calibrate external devices.
tSt dsP SELECT key tests display sections.
OPERATION
ALARMS
Wind speed and direction alarms each have their own set-point,
LED status indicator, and relay contacts. An Alarm Delay parameter
establishes the time duration in or out of the set-point range needed
for the alarm to change state. During operation, front panel LEDs
indicate alarm status.
LED Off = Alarm not armed and OFF. Relay open
LED Steady = Alarm armed and OFF. Relay open
LED Blinking = Alarm ON. Relay closed. Audible beep if Sound
parameter has been set.
AVERAGING
When averaging is enabled, the front-panel AVG annunciator is
illuminated, and average wind speed and direction values are
displayed at intervals set by the Period (PEr) parameter. When
disabled, instantaneous wind values are displayed.