MODEL 05608C
WIND SENSOR INTERFACE
0-5 VDC OUTPUT
INSTRUCTION SHEET 05608C-90
REV: A010313
SPECIFICATIONS
Sensor Type: Wind Monitor-HD (Model 05108)
NOTE: use with other models will result in
wind speed errors.
Wind Speed Input: AC sine wave, Frequency proportional to
wind speed. 3 pulses per revolution. Input
sensitivity nom. 40 mV p-p
Wind Direction Input: Analog voltage from azimuth potentiometer.
Regulated excitation voltage (nom
5.0vdc) is supplied from interface circuit to
potentiometer.
Wind Speed Output: 0 to 5.00 VDC = 0-100 M/S
Circuit time constant 0.2 second
Wind Direction Output: 0 to 5.00 VDC = 0 to 360°
Overall accuracy: ± 1% of full scale over temperature and
supply voltage range
Dimensions: 110 mm W x 75 mm H x 56 mm D
(4.3 in W x 2.9 in H x 2.2 in D)
Mounting: U-bolt for vertical pipe
25-50mm (1-2 in) Diameter
Power Requirement: 8-24 VDC (5 mA @ 12 VDC)
Temperature Range: -50 to 50°C (-58 to 122°F)
INTRODUCTION
The Wind Sensor Interface provides calibrated analog DC voltage
signals for wind speed and wind direction. The unit consists of a
circuit board assembly in a weather resistant junction box. All cable
connections are made in the junction box. See wiring diagram below.
IMPORTANT!
The Wind Sensor Interface provides a cal ibrated voltage
output signal for wind speed and wind direction. Externally
connected devices should be reviewed for compatibility and
correct signal scaling.
Repairs should be attempted only by qualied service personnel.
WARRANTY
Thi s p ro du ct is warranted to be free of defects in materials and
construction for a period of 12 months from date of initial purchase.
Liability is limited to repair or replacement of defective item. A copy
of the warranty policy may be obtained from R. M. Young Company.
CE COMPLIANCE
This product has been tested and shown to comply with European
CE requirements for the EMC Directive. Please note that shielded
cable must be used.
Declaration of Conformity
R. M. Young Company
2801 Aero Park Drive
Traverse City, MI 49686 USA
Model 05608C Wind Sensor Interface conforms to the provisions of
Council Directive 2004/108/EC (December 15, 2004) on Electromagnetic
Compatibility
R. M. YOUNG COMPANY 2801 Aero Park Drive, Traverse City, Michigan 49686 USA
TEL: 231-946-3980 FAX: 231-946-4772