Simplicity Allows for Ease of Use
TX10 Series of Digital Thermometers
TX10 Series offers thermocouple thermometers that support K, J, E and T type thermocouples.
There are three models available: 1-channel single-function, 1-channel multi-function, and 2-channel
multi-function models.
1-channel Single-function Model (TX1001)
Select the thermocouple type (K, J, E, and T) for
TC TYPE
Operation
DATA HOLD
Multi-function Models (TX1002/03)
● Memory-in Function
Up to ten data items can be stored. When recalled, the stored data
value is displayed with its memory number.
● User calibration function
Calibration and adjustment can be mode easily by operating the panel
keys on instrument and a measurement-standard.
the initial setting.
(The type K is factory-set at shipment)
Press and hold down the TC TYPE key while pressing the POWER key.
The TX10 enters the thermocouple type selection
mode, and each press of the TC TYPE key switches
between the thermocouple types.
Then accept the setting with the POWER key.
(Make sure that the characters in the display have changed.)
Press this key to hold the measured value.
TC TYPE
CH
(TX1003 only)
DATA HOLD
RECORD
RANGE
READ
REL/
ADJ
Thermocouple type (K, J, E, and T) select key
(Operation is the same as TX1001)
Input channel select key
With each press, the channel switches through the
sequence of “chA,” “chB,” and then “chA-chB.”
Data hold key
A held measured value, can be stored in the
memory of an optional memory number, which is
selected with the ▲, ▼ keys.
· Maximum and minimum record key
Stores the maximum and minimum values from the
time the RECORD key is pressed.
· Data record key
Stores the held measured value in memory. (Up to
ten)
Resolution select key
With each press, resolution alternates between
0.1C and 1C.
(Within the range of -200.0C to 199.9C)
Maximum and minimum values, and stored
data read key
Every time this key is pressed, the maximum and
minimum values, stored data, and the current measured data are displayed in sequence.
· Relative display select key
Displays measured values with reference to the
value obtained immediately before this key was
pressed (relative value). Each press of this key can
select or release the relative display.
· Simplified correction mode key
Sets the correction value, and selects active/inactive of the simplified correction function.
Light
Weight:
180 g
(Shown above is the TX1003. The TX1002 has no CH key.)
▲, ▼ Data call-up key
Used to select a memory number when calling up
stored data. Also used to adjust the correction value
for simplified correction mode.

Can Be Used in Wide Variety of Applications
●Temperature management in a refrigerated warehouse
●Temperature management
in production processes
Product name
Model
Number of input channels
Measuring range
(only the main unit)
Resolution
Accuracy
(only the main unit)
Temperature coefficient
Measurement interval
Data storage
Simplified correction
Display items
Other functions
Display
Operating temperature and humidity
Power requirements
Battery life
Drip-proof construction
Compliance with standards
●Frozen food products
quality control
●Product temperature
measurement test
Digital Thermometer
Single-function, 1 channel Multi-function, 1 channel Multi-function, 2 channels
TX1001
1
Thermocouple type Type K: -200°C to 1372°C Type E: -200°C to 700°C
-200.0°C to 199.9°C: 0.1°C
200°C or above: 1°C
HOLD,°C, ch A, TC type K, J, E, T,
Battery alarm
Type J: -200°C to 1000°C Type T: -200°C to 400°C
-200.0°C to -100.1°C: ±(0.1% of rdg + 1.0°C)
-100.0°C to 199.9°C: ±(0.1% of rdg + 0.7°C)
+200°C or above, or when 1°C resolution is set: ±(0.2% of rdg + 1°C)
± (0.015% of rdg +0.06°C)/°C
Approx. 1 sec.
None
None
HOLD, RCD, REL, ADJ, MAX, MIN, MEM, °C
chA, TC type K, J, E, T
Battery alarm
Auto power-off, battery alarm
0°C to 50°C, 20 to 80% RH (no condensation)
Two AA-size alkaline dry batteries (LR6)
Conforms to IP54 (dust-proof and drip-proof requirements of IEC529)
EMC standards EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1)
EMS (immunity): EN50082-1;1997, EN61326;1998+A1
TX1002
-200.0°C to 199.9°C: 0.1°C or 1°C (when 1°C resolution is set)
+200°C or above: 1°C
About 450 hours
●Perishable foods
quality control
●
Temperature checks in equipment maintenance
●Temperature management for research
and development
Approx. 1 sec. (1 channel measurement)
Approx. 2 sec. (2 channel measurement)
Capable of storing up to 10 measured data items
Correction range: ±20°C of measured value
HOLD, RCD, REL, ADJ, MAX, MIN, MEM, °C
chA, chB, chA-chB
TC type K, J, E, T
Battery alarm
LCD
33
TX1003
2
*
Accuracy of reference junction
compensation is included ±0.4°C
when the temperature of the input
terminal is in equilibrium.
External dimensions
Supplied accessories
Optional accessories
151
Approx. 151(H) × 56(W) × 33(D) mm (excluding protrusions) Weight: Approx. 180 g (including batteries)
Two AA-size alkaline dry batteries (LR6) and instruction manual
Temperature probes (for K type thermocouple)
Extension cable 5 m (245921) /10 m (245922)
Soft case (93012)
Waterproof cover (5·per package) (93011)
56
Rounded end probe (90020B, 90021B, 90022B)
Needle probe (90023B, 90024B)
Surface probe (90030B, 90031B, 90032B, 90033B)
Bead TC (90029B)
29

Specifications of Accessories
Model
90020/21/22/23/24/30/31/32/33
245907
99009
99008
245921
245922
93012
93011
Product name
Temperature probe (for type K)
Bead TC (for type K)
K-shape connector
U-shape connector (for input voltage) (for TM20 only)
Extension cable (5 m)
Extension cable (10 m)
Soft case
Waterproof cover (5 per package) (for TM10, TM20, TX10)
NOTE:
Please purchase commercially available thermocouples (Type-E/J/T), connectors and extention cables.
Temperature Probe (for type K)
Model
Probe type Measuring range Tolerance
90020B
rounded end
90021B
rounded end
90022B
rounded end
90023B
needle
90024B
needle
90030B
Surface straight
90031B
Surface angled
90032B
Surface straight
90033B
Surface angled
90029B
Bead TC
NOTE: 90030 is using polyimide to insulate from objects to be measured.
Manufacturers of polyimide are announcing not to apply polyimide directly for food, internal and body fluid.
-50 to 600°C
-50 to 600°C
-50 to 600°C
-50 to 500°C
-50 to 500°C
-20 to 250°C
-20 to 250°C
-20 to 500°C
-20 to 500°C
-40 to 260°C
T < 375°C: ±1.5°C
375°C ≤ T: ±0.004
(T-Ts) ≤ 100°C: ±2.5°C
100°C < (T-Ts): -0.03
T: -20°C to 250°C, Ts: 0°C to 40°C
333°C ≤ (T-Ts): +0.0075
167°C ≤ (T-Ts): -0.015
T: -20°C to 500°C, Ts: 0°C to 40°C
× T°C to +2.5°C
(T-Ts) < 333°C: +2.5°C
(T-Ts) < 167°C: -2.5°C
±2.5°C
× T°C
× T°C
× T°C
Response
time (second)
1.4
0.4
1.4
0.4
1
2
2
2
2
(90% response)
Dimenter / Length (m/m)
φ3.2 / 200
φ1.6 / 150
φ3.2 / 500
φ1.6 / 100
φ2.1 / 100
φ15 (temp. sensing portion)
φ15 (temp. sensing portion)
φ15 (temp. sensing portion)
φ15 (temp. sensing portion)
1200 (included cord)
External Dimensions for 900 series
90020B
Material: SUS316
90021B
Material: SUS316
90022B
Material: SUS316
90023B
Material: SUS316
90024B
Material: SUS316
90029B
φ 3.2
φ 1.6
500
φ 3.2
45°
φ 1.6
45°
φ 2.1
13
φ 22
13
φ 22
13
110
φ 22
φ 22
13
110100
φ 22
1200
Sensor
Optional Accessories for TX10Probes for TX10
Cord length
1.2 m
1.2 m
1.2 m
1.2 m
1.2 m
1.2 m
1.2 m
1.2 m
1.2 m
1200110200
heat-resistant
φ 14
PVC
1200110150
heat-resistant
φ 14
PVC
1200
heat-resistant
φ 14
PVC
1200110100 13
heat-resistant
φ 14
PVC
1200
silicon
φ 14
rubber
90030B
Material: SUS304
90032B
Material: SUS304
90031B
Material: SUS304
90033B
Material: SUS304
φ 4.8φ 4.8
46
φ15
45.5
φ15
56
φ 15
14
φ 6
26
φ 22
110
12
55.5
φ 15
13.5
φ 6
φ 22
25.5
110
12
100
φ 22φ 22
29
14
110
12
100
28.5
13.5
110
12
1200
silicon
φ 14
rubber
1200
silicon
φ 14
rubber
1200
silicon
φ 14
rubber
1200
silicon
φ 14
rubber
NOTICE
● Before using the product, read the instruction manual
carefully to ensure proper and safe operation.