Main Specification
100MB
DLM 2000 Series
Models
Model name
Frequency bandwidth
Input terminal Max. sample rate
DLM2022 (710105) 200MHz
DLM2032 (710115) 350MHz 2 analog channels
DLM2024 (710110) 200MHz
DLM2034 (710120) 350MHz 3 analog channels +
DLM2054 (710130) 500MHz
Basic Specifications
Analog Signal input
Input channels Analog input DLM20x2: CH1, CH2
Input coupling setting AC, DC, DC50 , GND Input impedance Analog input 1 M±1.0%, approximately 20 pF
Voltage axis sensitivity 1 M 2 mV/div to 10 V/div (steps of 1-2-5) setting range 50 2 mV/div to 500 mV/div (steps of 1-2-5) Max. input voltage 1 M 150 Vrms (CAT I)
Max. DC offset 1 MΩ±1V (2 mV/div to 50 mV/div) setting range ±10V (100 mV/div to 500 mV/div)
50 Ω ±1.0% (VSWR 1.4 or less, DC to 500MHz)
50 Must not exceed 5 Vrms or 10 Vpeak
50 Ω±1V (2 mV/div to 50 mV/div)
1
DC accuracy* Offset voltage accuracy*
±(1.5% of 8 div + offset voltage accuracy)
1
2 mV to 50mV/div ±(1% of setting +0.2 mV) 100 mV to 500 mV/div ±(1% of setting + 2 mV) 1 V to 10 V/div ±(1% of setting + 20 mV)
Frequency characteristics (-3 dB attenuation when inputting a sinewave of amplitude ±3div)*
1 M(when using passive probe)
50
Isolation between channels -34 dB@ analog bandwidth (typical value) Residual noise level*
100 mV to 100 V/div DC to 200 MHz DC to 350 MHz DC to 500 MHz 20 mV to 50 mV/div DC to 150 MHz DC to 300 MHz DC to 400 MHz
10 mV to 10 V/div DC to 200 MHz DC to 350 MHz DC to 500 MHz 2 mV to 5 mV/div DC to 150 MHz DC to 300 MHz DC to 400 MHz
3
A/D resolution 8bit (25LSB/div)
Bandwidth limit FULL, 200 MHz, 100MHz, 20 MHz, 10 MHz,
Maximum sample rate Real time sampling mode Interleave OFF 1.25 GS/s
Repetitive sampling mode
Maximum record length 2 ch model Repeat/Single/Single Interleave:
4 ch model Repeat/Single/Single Interleave:
4 ch model Repeat/Single/Single Interleave:
Ch-to-Ch deskew ±100 ns Time axis setting range 1 ns/div to 500 s/div (steps of 1-2-5) Time base accuracy ±0.002% Max. acquisition rate*
Interleave ON 2.5 GS/s
(Standard) 1.25 M/6.25 M/12.5 MPoints 2 ch model Repeat/Single/Single Interleave: (/M1S) 6.25 M/25 M/62.5 MPoints
(Standard) 1.25 M/6.25 M/12.5 MPoints
(/M1) 6.25 M/25 M/62.5 MPoints 4 ch model Repeat/Single/Single Interleave: (/M2) 12.5 M/62.5 M/125 MPoints
4
Dead time in N Single mode Approx. 2.2 µs
Logic Signal Input (4 ch model only)
Number of inputs 8 bit (excl. 4 ch input and logic input) Maximum toggle frequency*
1
Compatible probes 701988, 701989 (8 bit input)
Min. input voltage 701988: 500 mVp-p
Input range Model 701988: ±40 V
Max. nondestructive input voltage ±40 V (DC + ACpeak) or 28 Vrms (when using
Threshold level setting range
Input impedance 701988: Approx. 1 M/approx. 10 pF
Maximum sampling rate 1.25 GS/s Maximum record length Standard Repeat: 1.25 MPoints, Single: 6.25 MPoints
/M1, /M1S option Repeat: 6.25 MPoints, Single: 25 MPoints /M2 option Repeat: 12.5 MPoints, Single: 62.5 MPoints
4 analog channels /
8bit logic
DLM20x4: CH1 to CH4 (CH1 to CH3 when using logic input)
±100V (1 V/div to 10 V/div)
±5V (100 mV/div to 500 mV/div)
DLM202x DLM203x DLM205x
The larger of 0.4 mV rms or 0.05 div rms (typical value)
Max. 12 bit (in High Resolution mode)
5 MHz, 2 MHz, 1 MHz, 500 kHz, 250 kHz, 125 kHz, 62.5 kHz, 32 kHz, 16 kHz, 8 kHz (can be set for each channel)
125 GS/s
Approx. 20,000 waveform/sec/ch (Accumulation mode)
(approx. 450,000 waveforms/sec/ch)
Model 701988: 100 MHz Model 701989: 250 MHz
(701980, 701981 are available)
701989: 300 mVp-p
Model 701989: threshold ±6V
701989) Model 701988: ±40 V (setting resolution of 0.05 V) Model 701989: ±6 V (setting resolution of 0.05 V)
701989: Approx. 100 k/approx. 3 pF
1.25GS/s
2.5GS/s
(interleave mode on)
1*2
Triggers
Tr igger modes Auto, Auto Level, Normal, Single, N-Single Tr igger type, trigger source
Tr igger level setting range Tr igger level setting resolution Tr igger level accuracy CH1 to CH4 ±(0.2 div + 10% of trigger level) Window Comparator Center/Width can be set on individual Channels
A triggers Edge CH1 to CH4, Logic, EXT, LINE
AB triggers A Delay B 10 ns to 10 s (Edge, Edge
CH1 to CH4 ±4 div from center of screen CH1 to CH4 0.01 div (TV trigger: 0.1 div)
Edge OR CH1 to CH4 Edge Qualified State CH1 to CH4, Logic Pulse width CH1 to CH4, Logic, EXT State width CH1 to CH4, Logic TV CH1 to CH4 Serial Bus
2
I
SPI (optional) UART (optional) CAN (optional) LIN (optional)
User defined CH1 to CH4
A to B(N) 1 to 10
Dual Bus Serial bus only
CH1 to CH4, Logic, EXT
C (optional) CH1 to CH4, Logic
CH1 to CH4, Logic CH1 to CH4, Logic CH1 to CH4 CH1 to CH4
Qualified, State, Serial Bus)
9
(Edge, Edge Qualified,
State, Serial Bus)
from CH1 to CH4
Display
Display 8.4-inch TFT color liquid crystal display
1024 x 768 (XGA)
Functions
Waveform acquisition modes Nor mal, Envelope, Average High Resolution mode Max. 12 bit (the resolution of the A/D converter
Sampling modes Real time, interpolation, repetitive sampling Accumulation Select OFF, Intensity (waveform frequency by
Roll mode Enabled at 100 ms/div to 500 s/div (depending on
Accumulation time 100 ms to 100 s, Infinite
Zoom function Two zooming windows can be set independently
Zoom factor x2 to 2.5 points/10div (in zoom area) Scroll Auto Scroll Search functions Edge, Edge Qualified, State, Pulse Width, State
History memory Max. data
History search Select Rect, WAVE, Polygon, or Parameter mode Replay function Automatically displays the history waveforms
Cursor Types T, V, T & V, Marker, Degree Snapshot Currently displayed waveform can be retained on
Display Specified or average waveforms
can be improved equivalently by placing a bandwidth limit on the input signal.)
brightness), or Color (waveform frequency by color)
the record length setting)
(Zoom1, Zoom2)
Width
2
C (option), SPI (option), UART (option),
I CAN (option), LIN (option) 2,500 (record length 1.25 kPoints, with standard) 10,000 (record length 1.25 kPoints, with /M1 or /M1S option) 20,000 (record length 1.25 kPoints, with /M2 option)
sequentially
screen
Computation & Analysis Functions
Parameter measurement MAX, MIN, P-P, HIGH, LOW, Rms, Mean, Sdev,
Statistical computation of parameters Min, Max, Ave, Cnt, Sdev Statistics modes Continuous, Cycle, History Trend/Histogram display of wave parameters Up to 2 trend or histgram display of specied wave
Computations (MATH) +, -, x, Filter (Delay, Moving Avg, IIR Lowpass, IIR
Computable no. of traces 2 (Math1, Math2) (1 trace for 2ch model) Max. computable memory length Standard model: 6.25 MPoints, /M1,/M2 memory
Reference function Up to 2 traces (REF1/REF2) of saved waveform
Action ON trigger Modes All Condition, Zone, Param, Rect, Polygon
Analysis XY Displays XY1, XY2 and T-Y simultaneously
Actions Buzzer, Print, Save, Mail, GO-NOGO out
FFT Number of points: 1.25k, 12.5k, 125k, 250k
Histogram Displays a histogram of acquired waveforms User-defined math The following operators can be arbitrarily (/G2 Options) combined in equations: (Release soon) +, -, x, /, SIN, COS, TAN, ASIN, ACOS, ATAN,
IntegTY+, IntegTY, +OVER,
-OVER, Pulse Count, Edge Count, V1, V2, T, Freq, Period, Avg Freq, Avg Period, Burst, Rise, Fall, +Width, -Width, Duty, Delay
parameters
Highpass), Integ, Count, user defined math (optional)
expansion option: 25 MPoints, /M2 expansion option: 62.5 MPoints
data can be displayed and analyzed
Window functions: Rectangular, Hanning, Flat-Top FFT Types: PS (LS, RS, PSD, CS, TF, CH are available with /G2 option)
INTEG, DIFF, ABS, SQRT, LOG, EXP, LN, BIN, DELAY, P2 (power of 2), PH, DA, MEAN, HLBT, PWHH, PWLL, PWHL, PWLH, PWXX, FV, DUTYH, DUTYL,
The maximum record length that can be
Power supply analysis function (/G4 option) The difference in propagation time of voltage and
(Release soon) Automated measurement of power supply
2
C Bus Signal Analysis Functions (/F2 & /F3 Options)
I
Applicable bus I
2
C Tr igger modes Every Start, Address & Data, Non-Ack, General
I
Analyzable signals Analysis results displays Analysis no., time from trigger position (Time
2
C bus Bus transfer rate: 3.4 Mbit/s max.
SM bus Complies with System Management Bus
Auto setup function Auto setting of bit rate, threshold value, time axis
Analyzable no. of data 300,000 bytes max. Search function Searches data that matches specified address
Analysis results save function Analysis list data can be saved to CSV-format files
computed is as well as standard math functions Propagation time difference correction (deskew):
current probe signals can be automatically or manually corrected. Correction range is ±100 ns (0.01 ns resolution)
analysis parameters: Power supply analysis parameters can be measured automatically and simultaneously with standard measurement items. (Automated measurement of two areas is also possible) Waveform computation of power supply analysis parameters: Wp, Wp+, Wp-, Abs.Wp., P, P+, P-, Abs.P, Z(Impedance) Display of the Area of Voltage-Current Operation: Allows for checking whether it is within the ASO(area of safe operation) Harmonic analysis: Harmonic current emission standard IEC 61000­3-2 edition 2.2(EN61000-3-2 (2000)) Trend display:
Address mode: 7 bit/10 bit
Call, Start Byte, HS Mode Assignable to CH1 to CH4, Logic input, or M1 to M2
(ms)),1st byte address, 2nd byte address, R/W, Data, Presence/absence of ACK, information
scale, voltage axis scale, and display of analysis results
pattern, data pattern, and acknowledge bit condition
SPI Bus Signal Analysis Functions (/F2 & /F3 Options)
Tr igger types 3 wire/4 wire
Byte order MSB/LSB Auto setup function Auto setting of bit rate, threshold value, time axis
Analyzable no. of data 300,000 bytes max. Decode bit length Specify data interval (1 to 32 bits), decode start
Analysis results displays Analysis no., time from trigger position (Time
Auxiliary analysis functions Data search function Analysis result save function Analysis list data can be saved to CSV-format files
After assertion of CS, compares data after arbitrary byte count and triggers.
scale, voltage axis scale, and display of analysis results
point, and data length
(ms)), Data 1, Data 2
UART Bus Signal Analysis Functions (/F1 & /F3 Options)
Bit rate
Data format Select a data format from the following 8 bit (Non
UART Tr igger modes Every Data, Data, Error (Framing, Parity) Analyzable signals Select CH1 to CH4, logic input, or M1 to M2 Auto setup function Auto setting of bit rate, threshold value, time axis
Analyzable no. of frames 300,000 frames max. Analysis results displays Analysis no., time from trigger position
Auxiliary analysis functions Data search Analysis result save function Analysis list data can be saved to CSV-format files
1200 bps, 2400 bps, 4800 bps, 9600 bps,19200 bps, user defined (an arbitrary bit rate from 1 k to 1 Mbps with resolution of 100 bps)
Parity) / 7 bit Data + Parity / 8 bit + Parity
scale, voltage axis scale, and display of analysis results
(Time(ms)), Data (Bin, Hex) display, ASCII display, and Information.
CAN Bus Signal Analysis Functions (/F4 Option)
Applicable bus CAN version 2.0A/B, Hi-Speed CAN (ISO11898),
Bit rate 1 Mbps/500 kbps/250 kbps/125 kbps/83.3 kbps/
CAN bus Trigger modes SOF, ID/DATA, ID OR, Error(enabled when
Auto setup function Auto setting of bit rate, threshold value, time axis
Analyzable no. of frames 100,000 frames max. Analysis results displays Analysis no., time from trigger position (Time
Low-Speed CAN (ISO11519-2)
33.3 kbps User defined ( an arbitrary bit rate from 10.0 kbps to 1.000 Mbps with resolution of 100 bps)
loading physical values/symbol definitions)
scale, voltage axis scale, and display of analysis results
(ms)), Frame type, ID, DLC, Data, CRC, presence/absence of Ack, information
Auxiliary analysis functions Data search and field jump functions Analysis result save function Analysis list data can be saved to CSV-format files
LIN Bus Signal Analysis Functions (/F4 Option)
Applicable bus LIN Rev. 1.3, 2.0 Bit rate 19.2 kbps, 9.6 kbps, 4.8 kbps, 2.4 kbps, 1.2 kbps
LIN bus Trigger modes Auto setup function Auto setting of bit rate, threshold value, time axis
Analyzable no. of frames 100, 000 frames max. Analysis results displays Analysis no., time from trigger position (Time
Auxiliary analysis functions Analysis result save function
User defined (an arbitrary bit rate from 1000 bps to 200 kbps with resolution of 100 bps) Break Synch, ID/DATA, ID OR, and ERROR trigger
scale, voltage axis scale, and display of analysis results
(ms)), ID, ID-Field, Data, CheckSum, information Data search and field jump functions Analysis list data can be saved to CSV-format files
GP-IB (/C1 & /C11 Options)
Electromechanical specifications Protocol Conforms to IEEE std. 488.2-1987
Conforms to IEEE std. 488-1978 (JIS C 1901-1987)
Auxiliary Input
Rear panel I/O signal External trigger input(DLM20x2: front panel),
Probe interface terminal (front panel) 4 terminals (DLM20x4) Probe power terminal (rear panel) 2 terminals (/P2 option)
external trigger output, GO-NOGO output, video output
4 terminals (/P4 option)
Built-in Storage (Standerd model /C8 Option)
Capacity Standard model: 100 MB
/C8 option: 1.8 GB
Built-in Printer (/B5 Option)
Built-in printer 112 mm wide, monochrome, thermal
USB Peripheral Connection Terminal
Connector USB type A connector x 2 (front panel x 1, rear
Electromechanical specifications USB 2.0 compliant Supported transfer standards Low Speed, Full Speed, High Speed Supported devices USB Pr inter Class Ver. 1.0 compliant EPSON/HP
panel x 1)
(PCL) ink jet printers USB Mass Storage Class Ver. 1.1 compliant mass storage devices* Please contact your local Yokogawa sales office for model names of verified devices
USB-PC Connection Terminal
Connector USB type B connector x 1 Electromechanical specifications USB 2.0 compliant Supported transfer standards High Speed, Full Speed
Supported class
USBTMC-USB488 (USB Test and Measurement Class Ver. 1.0)
Ethernet (/C10 & /C11 Options)
Connector RJ-45 connector x 1 Transmission methods Ethernet (1000BASE-T/100BASE-TX/10BASE-T) Supported services Server: FTP, VXI-11
Client: SMTP, SNTP, LPR, DHCP, DNS
General Specifications
Rated supply voltage 100 to 240 VAC Rated supply frequency 50 Hz/60 Hz Maximum power consumption External dimensions 226 (W) x 293 (H) x 193 (D) mm (when printer
Weight Approx.4.2kg With no options Operating temperature range
*1 Measured under standard operating conditions after a 30-minute warm-up followed by calibration.
Standard operating conditions: Ambient temperature: 23˚C ±5˚C
Error in supply voltage and frequency: Within 1% of rating
*2 Value in the case of repetitive phenomenon. The frequency bandwidth of a single-shot phenomenon is the smaller of the two
values, DC to sampling frequency/2.5 or the frequency bandwidth of the repetitive phenomenon.
*3.When the input section is shor ted, the acquisition mode is set to Normal, accumulation is OFF, and the probe attenuation is
set to 1:1.
*4.Acquisition rate does not vary with an increase or decrease in channels.
Ambient humidity: 55 ±10% RH
170 VA
cover is closed, excluding protrusions)
5 ˚C to 40 ˚C
External Dimensions
Unit: mm
10 11
Model and Suffix Codes Standard Main Unit Accessories
Model Suffix code Description
710105
*1
710110 710115
*1
710120 710125
*1
710130 Power cable
-D
-F
-Q
-R
-H
Help language
-HE
-HC
-HK
-HG
-HF
-HI
-HS
Option
/LN /B5
/M1
Digital Oscilloscope DLM2022 2ch, 200MHz Mixed Signal Oscilloscope DLM2024 4ch, 200MHz Digital Oscilloscope DLM2032 2ch, 350MHz Mixed Signal Oscilloscope DLM2034 4ch, 350MHz Digital Oscilloscope DLM2052 2ch, 500MHz Mixed Signal Oscilloscope DLM2054 4ch, 500MHz UL/CSA standard VDE standard BS standard AS standard GB standard English Help (Menu and Panel) Chinese Help (Menu and Panel) Korean Help (Menu and Panel) German Help (Menu and Panel) French Help (Menu and Panel) Italian Help (Menu and Panel) Spanish Help (Menu and Panel) No switchable logic input (4 ch model only) Built-in printer "Memory expansion option (4 ch model only)
*2
During continuous measurement: 6.25 Mpoints; Single mode: 25 Mpoints (when interleave mode ON: 62.5 Mpoints)" "Memory expansion option (4 ch model only)
*2
/M2
During continuous measurement: 12.5 Mpoints; Single mode:
62.5 Mpoints (when interleave mode ON: 125 Mpoints)" "Memory expansion option (2 ch model only)
/M1S
/P2 /P4 /C1 /C10 /C11 /C8 /G2
/G4
/F1 /F2 /F3 /F4
*1: Logic probes sold separately. Please order the model 701988/701989 accessory logic probes separately. *2: Only one of these may be selected at a time. *3: Specify this option when using current probes or other differential probes such as models 701920 or 701922. *4: Only one of these may be selected at a time. *5: Only one of these may be selected at a time. *6: Only one of these may be selected at a time.
During continuous measurement: 6.25 Mpoints; Single mode: 25 Mpoints (when interleave mode ON: 62.5 Mpoints)"
*3
Probe power for 2 ch models
*3
Probe power for 4 ch models
*4
GP-IB Interface
*4
Ethernet Interface
*4
GP-IB + Ethernet Interface Internal storage (1.8 GB)
*5
User defined math (4 ch model only) (Release soon) "Power supply analysis function (includes /G2) (4 ch model only)
*5
(Release soon)"
*6
UART trigger and analysis (4 ch model only)
2
*6
I
C + SPI trigger and analysis (4 ch model only)
*6
2
UART + I
C + SPI trigger and analysis (4 ch model only)
CAN + LIN trigger and analysis (4 ch model only)
Power cord (with 3-prong to 2-prong adapter) "Passive probe, model 701938 (200 MHz, 1.5 m)
For models 710105, 710110" "Passive probe, model 701939 (500 MHz, 1.3 m)
For models 710115, 710120, 710125, 710130" Protective front cover Soft carrying case for probes Printer roll paper (for /B5 option) User's manuals
Accessory Models
Name Model Specification
Logic probe (PBL100) Logic probe (PBL250) Passive probe Passive probe FET Pprobe Active probe (PBA1000) 100:1 voltage probe 100:1 voltage probe Differential probe Differential probe Differential probe (PBDH1000) Differential probe Differential probe Differential probe Current probe (PBC050) Current probe (PBC100) Current probe Current probe Mini clip converter BNC adapter PCB adapter
Solder-in adapter
Printer roll paper
Xviewer
Probe stand Carrying case
Part Name Quantity
701988 701989 701938 701939 700939 701912 701944 701945 701921 701922 701924 700924 700925 701920 701929 701928 701930 701931 700971 700972 366945
366946
B9988AE 701992-SP01 701992-GP01 701919 701964
DLM 2000 Series
1
Per number of channels
Per number of channels
1
1 1 roll 1 set
1 M input resistance, toggle frequency of 100 MHz 100 k input resistance, toggle frequency of 250 MHz 10 M (10:1), 200 MHz, 1.5 m 10 M (10:1), 500 MHz, 1.2 m DC to 900 MHz bandwidth/2.5M/1.8pF DC to 1 GHz bandwidth/100k/0.9pF DC to 400 MHz, 1.2 m, 1000 Vrms DC to 250 MHz, 3 m, 1000 Vrms DC to 100 MHz bandwidth/max. ±700 V DC to 200 MHz bandwidth/max. ±20 V DC to 1 GHz bandwidth/1M/max. ±25 V DC to 100 MHz bandwidth/max. ±1400 V DC to 15 MHz bandwidth/max. ±500 V DC to 500 MHz bandwidth/max. ±12 V DC to 50 MHz bandwidth, 30 Arms DC to 100 MHz bandwidth, 30 Arms DC to 10 MHz bandwidth, 150 Arms DC to 2 MHz bandwidth, 500 Arms For models 701938 and 701939 For models 701938 and 701939 For models 701938 and 701939, 10 per set For models 701938 and 701939, 1 adapter,
red/black cables (3 ea.) Lot size is 10 rolls, 10 meters each For DL/WE series, standard version For DL/WE series, with MATH functions Round base, 1 arm Also for DL1600/DL1700E series
NOTE
"Before operating the product, read the users manual thoroughly for
proper and safe operation."
Yokogawa's Approach to Preserving the Global Environment
• Yokogawa's electrical products are deloped and produced in facilities that have received ISO14001 approval.
• In order to protect the glovel environment,Yokogawa's electrical products are designed in accordance with Yokogawa's Environmentally Friendy Product
Desigh Guidelines and Product Design Assessment Criteria.