YASKAWA DO-A3 Installation Manual

Page 1
YASKAWA 1000-Series Option
Digital Output
Installation Manual
Type
DO-A3
安川1000シリーズオプション
ディジタル出力
取扱説明書
形式
DO-A3
製品を安全にお使い頂くために,この取扱説明書を必ずお読みください。 また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。
MANUAL NO. TOBP C730600 41E
Page 2
Copyright © 2008 YASKAWA ELECTRIC CORPORATION
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
2 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 3

Table of Contents

1 PREFACE AND SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2 PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4 OPTION COMPONENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . 10
6 RELATED PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . .23
7 TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
YAS KAWA ELE CTR IC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 3
Page 4

1 Preface and Safety

DO
1 Preface and Safety
Yaskawa manufactures products used as components in a wide variety of industrial systems and equipment. The selection and application of Yaskawa products remain the responsibility of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control. Without exception, all controls should be designed to detect faults dynamically and fail safely under all circumstances. All systems or equipment designed to incorporate a product manufactured by Yaskawa must be supplied to the end user with appropriate warnings and instructions as to the safe use and operation of that part. Any warnings provided by Yaskawa must be promptly provided to the end user. Yaskawa offers an express warranty only as to the quality of its products in conforming to standards and specifications published in the Yaskawa manual. NO OTHER WARRANTY, EXPRESS OR IMPLIED, IS OFFERED. Yaskawa assumes no liability for any personal injury, property damage, losses, or claims arising from misapplication of its products.

Applicable Documentation

The following manuals are available for the option:
Digital Output DO-A3 Option
Yaskawa 1000-Series Option Digital Output DO-A3 Installation Manual (This book) Manual No: TOBP C730600 41
Unit
Yaskawa AC Drive 1000-Series Quick Start Guide
Yaskawa AC Drive 1000-Series Technical Manual
D1000 Instruction Manual
4 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Read this manual first. The installation manual is packaged with the option and contains information required to install the option and set up related unit parameters.
The unit manuals cover basic installation, wiring, operation procedures, functions, troubleshooting, and maintenance information. The manuals also include important information about parameter settings and unit tuning. Access these sites to obtain Yaskawa instruction manuals: U.S.: http://www.yaskawa.com Europe: http://www.yaskawa.eu.com Japan: http://www.e-mechatronics.com Other areas: contact a Yaskawa representative.
Page 5
1 Preface and Safety
DANGER
W ARNING
CAUTION

Terms

Note: Indicates supplemental information that is not related to safety messages
Option: Yaskawa 1000-Series Option Digital Output DO-A3
• Yaskawa AC Drive 1000-Series
Unit:
• Yaskawa Energy-Saving Unit Series D1000 High-Power-Factor Converter with Power Regeneration

Registered Trademarks

Trademarks are the property of their respective owners.

Supplemental Safety Information

Read and understand this manual before installing, operating, or servicing this option. Install the option according to this manual and local codes.
The following conventions indicate safety messages in this manual. Failure to heed these messages could cause fatal injury or damage products and related equipment and systems.
Indicates a hazardous situation, which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation, which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury.
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 5
Page 6
1 Preface and Safety
NOTICE
NOTICE
Indicates an equipment damage message.
General Safety
General Precautions
• The diagrams in this book may include options and units without covers or safety shields to illustrate details. Be sure to reinstall covers or shields before operating any devices. Use the option according to the instructions described in this manual.
• Any illustrations, photographs, or examples used in this manual are provided as examples only and may not apply to all products to which this manual is applicable.
• The products and specifications described in this manual or the content and presentation of the manual may be changed without notice to improve the product and/or the manual.
• When ordering new copies of the manual, contact a Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover.
DANGER
Heed the safety messages in this manual.
Failure to comply will result in death or serious injury.
The operating company is responsible for any injuries or equipment damage resulting from failure to heed the warnings in this manual.
Do not modify the unit or option circuitry.
Failure to comply could result in damage to the unit or option and will void warranty.
Yaskawa is not responsible for any modification of the product made by the user. This product must not be modified.
Do not expose the unit or option to halogen group disinfectants.
Failure to comply may cause damage to the electrical components in the unit or option.
Do not pack the unit in wooden materials that have been fumigated or sterilized.
Do not sterilize the entire package after the product is packed.
6 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 7

2 Product Overview

2 Product Overview

About This Product

The Digital Output Option DO-A3 allows the user to expand the number of available digital outputs to monitor unit run status.
The option has the following features:
• Six photocoupler outputs (48 V, 50 mA or less)
• Two relay outputs (250 Vac, 1 A or less; 30 Vdc, 1 A or less)

Applicable Models

The option can be used with the unit models in Tab le 1 .
Table 1 Applicable Models
Unit Series Unit Model Number
A1000 All models
L1000A All models
D1000 All models
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 7
Page 8

3 Receiving

MANUAL
3 Receiving
Please perform the following tasks upon receiving the option:
• Inspect the option for damage. Contact the shipper immediately if the option appears damaged upon receipt.
• Verify receipt of the correct model by checking the model number printed on the option nameplate. (Refer to Figure 1 on page 9 for more information)
• Contact your supplier if you have received the wrong model or the option does not function properly.

Option Package Contents

Description: Option Ground Wires Screws (M3) Installation Manual
Quantity: 1331

Tools Required for Installation

• A Phillips screwdriver (M3 metric / #1, #2 U.S. standard size <1>) is required to install the option.
• A straight-edge screwdriver (blade depth: 0.4 mm, width: 2.5 mm) is required to wire the option terminal block.
• A pair of diagonal cutting pliers. (required for some unit models)
• A small file or medium grit sandpaper. (required for some unit models)
Note: Tools required to prepare option cables for wiring are not listed in this manual.
<1> Select a screwdriver appropriate for the unit capacity.
8 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 9
4 Option Components
DO
P1 P2 P3 P4 P5 P6 PC
M1 M2 M3 M4
TB2
TB1
DO

Digital Output DO-A3 Option

Figure 1
F

4 Option Components

A
B
Underside
E
A – Connector (CN5) D – Model number B – Installation hole E – Ground terminal and installation
C – Terminal block TB2 F – Terminal block TB1
<1> The ground wires provided in the option shipping package must be connected during installation.
DO-A3
C
D
Figure 1 Digital Output DO-A3 Option Components
hole
<1>

Terminal Blocks TB1 and TB2

Refer to Ta bl e 4 on page 22 for details on TB1 and TB2 terminal functions and signal levels.
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 9
Page 10

5 Installation Procedure

W ARNING
5 Installation Procedure

Section Safety

DANGER
Electric Shock Hazard
Do not connect or disconnect wiring while the power is on.
Failure to comply will result in death or serious injury.
Disconnect all power to the unit and wait at least the amount of time specified on the unit front cover safety label. After all indicators are off, measure the DC bus voltage to confirm safe level, and check for unsafe voltages before servicing. The internal capacitor remains charged after the power supply is turned off.
Electrical Shock Hazard
Do not remove the front covers of the unit while the power is on.
Failure to comply could result in death or serious injury.
The diagrams in this section may include options and units without covers or safety shields to show details. Be sure to reinstall covers or shields before operating any devices. Use the option according to the instructions described in this manual.
Do not allow unqualified personnel to use equipment.
Failure to comply could result in death or serious injury.
Maintenance, inspection, and replacement of parts must be performed only by authorized personnel familiar with installation, adjustment, and maintenance of this product.
Do not touch circuit boards while the power to the unit is on.
Failure to comply could result in death or serious injury.
10 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 11
5 Installation Procedure
NOTICE
W ARNING
Do not use damaged wires, stress the wiring, or damage the wire insulation.
Failure to comply could result in death or serious injury.
Fire Hazard
Tighten all terminal screws to the specified tightening torque.
Loose electrical connections could result in death or serious injury by fire due to overheating of electrical connections.
Damage to Equipment
Observe proper electrostatic discharge (ESD) procedures when handling the option, unit, and circuit boards.
Failure to comply may result in ESD damage to circuitry.
Never shut the power off while the unit is running or outputting voltage.
Failure to comply may cause the application to operate incorrectly or damage the unit.
Do not operate damaged equipment.
Failure to comply may cause further damage to the equipment.
Do not connect or operate any equipment with visible damage or missing parts.
Tighten all terminal screws to the specified tightening torque.
Failure to comply could result in damage to the terminal block.
Do not use unshielded cable for control wiring.
Failure to comply may cause electrical interference resulting in poor system performance.
Use shielded twisted-pair wires and ground the shield to the ground terminal of the unit.
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 11
Page 12
5 Installation Procedure
NOTICE
Properly connect all pins and connectors.
Failure to comply may prevent proper operation and possibly damage equipment.
Check wiring to ensure that all connections are correct after installing the option and connecting any other devices.
Failure to comply may result in damage to the option.
12 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 13
5 Installation Procedure
E
G
L
K
J
I
H
B
A
C
D
F

Prior to Installing the Option

Prior to installing the option, wire the unit, make the necessary connections to the unit terminals, and verify that the unit functions normally. Refer to the instruction manual packaged with the unit for information on wiring and connecting the unit.
Figure 2 shows an exploded view of the unit with the option and related components for
reference.
Figure 2
A – Insertion point for CN5 G – Included screws B – Option card H – Ground wire C – Front cover I – Unit grounding terminal (FE) D – Digital operator J – Connector CN5-A E – Terminal cover K – Connector CN5-B F – Removable tabs for wire routing L – Connector CN5-C
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 13
Figure 2 Unit Components with Option
Page 14
5 Installation Procedure
C
D
E

Installing the Option

Refer to the instructions below to install the option.
1. Shut off power to the unit, wait the appropriate amount of time for voltage to
dissipate, then remove the digital operator (D), front cover (C), and terminal cover (E). Cover removal varies depending on unit size. Refer to the instruction manual packaged with the unit for directions on removing the covers.
DANGER! Electrical Shock Hazard. Disconnect all power to the unit and wait at least the amount of time specified on the unit front cover safety label. After all indicators are off, measure the DC bus voltage to confirm safe level, and check for unsafe voltages before servicing to prevent electric shock. The internal capacitor remains charged even after the power supply is turned off.
NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling the option, unit, and circuit boards. Failure to comply may result in ESD damage to circuitry.
Figure 3
Figure 3 Remove the Front Cover, Terminal Cover, and Digital Operator
14 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 15
5 Installation Procedure
2. Insert the option card (B) into the CN5-A (J), CN5-B (K), or CN5-C (L) connector
located on the unit and fasten it into place using one of the included screws (G).
Figure 4
L
K
J
B
G
Figure 4 Insert the Option Card
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 15
Page 16
5 Installation Procedure
I
G
H
B
3. Connect one end of the ground wire (H) to the ground terminal (I) using one of the
remaining screws (G). Connect the other end of the ground wire (H) to the remaining ground terminal and installation hole on the option (B) using the last
Figure 5
remaining provided screw (G).
Figure 5 Connect the Ground Wire
Note: 1. The option package includes three ground wires. Use the longest wire when plugging the option into
connector CN5-C on the unit side. Use the next longest wire when plugging the option into connector CN5-B. Use the shortest wire when plugging the option into connector CN5-A. Refer to Option
Package Contents on page 8 for more information.
2. There are two screw holes on the unit for use as ground terminals (J). When connecting three options, two ground wires will need to share the same unit ground terminal.
16 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 17
5 Installation Procedure
DO
DO
4. Prepare and connect the wire ends as shown in Figure 6 and Figure 7. Refer to
Wire Gauges and Tightening Torques on page 21 to confirm that the proper
tightening torque is applied to each terminal. Take particular precaution to ensure that each wire is properly connected and wire insulation is not accidentally pinched into electrical terminals.
WARNING! Fire Hazard. Tighten all terminal screws according to the specified tightening torque. Loose electrical connections could result in death or serious injury by fire due to overheating electrical connections. Tightening screws beyond the specified tightening torque may cause erroneous operation, damage the terminal block, or cause a fire.
NOTICE: Heat shrink tubing or electrical tape may be required to ensure that cable shielding does not contact other wiring. Insufficient insulation may cause a short circuit and damage the option or unit.
Figure 6
Option terminal
Figure 6 Preparing Ends of Shielded Cable
Figure 7
Insulation
To customer circuit
Shield sheath (Insulate with electrical tape or shrink tubing)
Preparing wire ends:
Pull back the shielding and lightly twist the end with fingers, keeping the ends from fraying.
about 5.5 mm (7/32”) When not using crimped insulated sleeves
Screwdriver blade size
Blade depth of
0.4 mm or less
Blade width of
2.5 mm or less
Loosen the screws and insert the wire into the opening on the terminal block.
To customer circuit
(do not solder ends)
Option terminal block
Figure 7 Preparing and Connecting Cable Wiring
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 17
Page 18
5 Installation Procedure
Ground wire
CN5-A/ CN5-B/ CN5-C
Unit
DO-A3
TB2
TB1
RLY1
RLY2
RLY3
RLY4
RLY5
RLY6
P1 P2
P4
P3
P5 P6 PC
M1 M2
M4
M3
RLY7
SA
RLY8
SA
DC power supply (48 V,max.50 mA)
Photocoupler output
Relay output
AC power supply (AC250 V,max.1 A) or DC power supply (30 V,max.1 A)
R/L1 S/L2 T/L3
<1>
<2>
FE
Main circuit terminal Control circuit terminal
DO
5. Wire the customer-supplied circuit to the terminal blocks on the option. Refer to
Figure 8 for wiring instructions.
Connection Diagram
Refer to Tabl e 4 on page 22 for a detailed description of the option board terminal
functions. To ensure accurate control, use stable power supply for the voltage
Figure 8
reference source.
<1> Double-check the polarity on the diode when connecting a DC relay. <2> Install a surge absorber (SA) when using an AC relay.
18 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Figure 8 Option Connection Diagram
Page 19
6. Route the option wiring.
A
B
Depending on the unit model, some units may require routing the wiring through the side of the front cover to the outside. In these cases, cut out the perforated openings on the left side of the unit front cover as shown in Figure 9-A and leave no sharp edges to damage wiring. Route the wiring inside the enclosure as shown in Figure 9-B for units that do not require routing through the front cover. Refer to the Peripheral Devices & Options section of the unit Instruction Manual for
Figure 9
more information.
5 Installation Procedure
Figure 9 Wire Routing Examples
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 19
Page 20
5 Installation Procedure
C
D
E
7. Replace and secure the front covers of the unit (C, E) and replace the digital
Figure 10
operator (D).
Figure 10 Replace the Front Covers and Digital Operator
Note: Take proper precautions when wiring the option so that the front covers will easily fit back onto
the unit. Make sure cables are not pinched between the front covers and the unit when replacing the covers.
8. Set unit parameters in Table 7 for proper option performance.
20 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 21
5 Installation Procedure
d1
d2
6 mm
L

Wire Gauges, Tightening Torques, and Ferrule-Type Terminals

Wire Gauges and Tightening Torques
Wire gauge and torque specifications are listed in Table 2.
Table 2 Wire Gauges and Tightening Torques
Ter min al
signal
P1 to P6, PC
M1 to M4 M3
Ferrule-Type Terminals
Screw
Size
M2
Tightening
Tor que
Nxm (inxlb)
0.22 to 0.25
(1.95 to 2.21)
0.5 to 0.6
(4.43 to 5.31)
(24 to 17 AWG)
(24 to 16 AWG)
(24 to 16 AWG)
(24 to 13 AWG)
Yaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent ferrule-type terminals with the specifications listed in Table 3 for wiring to ensure proper connections.
Note: Properly trim wire ends so loose wire ends do not extend from the crimp terminals.
Table 3 Ferrule-Type Terminal Sizes
Ferrule-Type
Terminal
Wire Gauge
2
mm
0.25 (24 AWG) AI 0.25 - 6YE 10.5 (13/32) 0.8 (1/32) 2 (5/64)
0.34 (22 AWG) AI 0.34 - 6TQ 10.5 (13/32) 0.8 (1/32) 2 (5/64)
0.5 (20 AWG) AI 0.5 - 6WH 14 (9/16) 1.1 (3/64) 2.5 (3/32)
Bare Cable Ferrule-Type Terminals
Applicable
Gauges mm
Stranded wire:
0.25 to 1.0
Solid wire:
0.25 to 1.5
Stranded wire:
0.25 to 1.5
Solid wire:
0.25 to 2.5
Phoenix Contact
Recomm.
2
Gauge mm
Model
0.75
(18 AWG)
Applicable
2
Gauges mm
0.25 to 0.5
(24 to 20 AWG)
0.25 to 1.0
(24 to 17 AWG)
L
mm (in)
Recomm.
2
Gauge mm
d1
mm (in)
0.5
(20 AWG)
2
Shielded twisted pair, etc.
d2
mm (in)
Wire Typ e
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 21
Page 22
5 Installation Procedure

Terminal Functions

Table 4 Option Terminal Functions
Ter min al
Block
<1> Set unit parameters to determine the function assigned to each output. See the unit Instruction Manual for
Ter min al Output <1> Output Type Output Level
M1
TB1
TB2
directions on setting parameters.
M2
M3
M4
P1 Photocoupler output 1
P2 Photocoupler output 2
P3 Photocoupler output 3
P4 Photocoupler output 4
P5 Photocoupler output 5
P6 Photocoupler output 6
PC Photocoupler output common Emitter common
Contact relay output 1
N.O. output
Contact relay output 2
Open-collector output
Max voltage and current: 250 Vac, 1 A 30 Vdc, 1 A
Max voltage and current: 48 Vdc, 50 mA
22 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 23

6 Related Parameters

6 Related Parameters
The parameters outlined in the following sections are used to set up the unit for operation with the option. Set parameters as needed. Parameter setting methods can be found in the drive unit Instruction Manual.

Parameter F5-09

Set parameter F5-09 to select the option output mode.
Ta bl e 5 shows the changes in the output terminal contents according to the output mode set
in F5-09.
Table 5 F5-09 and Output Mode
Ter mi nal
Block
TB1
TB2
F5-09 = 0
Ter min al
M1-M2 Zero speed During run Determined by F5-07
M3-M4 Speed agree Alarm (excluding bb) Determined by F5-08
P1-PC oC, GF (Overcurrent)
P2-PC ov (Overvoltage) Determined by F5-02
P3-PC
P4-PC Not used Determined by F5-04
P5-PC oS (Overspeed) Zero speed Determined by F5-05
P6-PC
Individual Output
(Default when Installed to
oH2 (Unit overheat) or oL2 (overload)
oH, oH1 (Unit overheat) or oL1 (Overload)
Drive)
F5-09 = 1
Binary Code Output
Binary code output (Refer to Table 6)
Speed agree Determined by F5-06
F5-09 = 2
Multi-Function Output
(Default when Installed
to D1000)
Determined by F5-01
Determined by F5-03
Table 6 Binary Coded Output (F5-09 = 1)
Coded Output Description
0Normal operation (no fault) 0000
1oC, GF (Overcurrent) 1000
2ov (Overvoltage) 0100
3oL2 (Unit overload) 1100
4oH, oH1 (Unit overheat) 0010
5oS (Overspeed) 1010
6Not used 0110
7rr, rH (Braking resistor overheat) 1110
8EF1 to EF12 (External fault) 0001
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 23
P1-PC P2-PC P3-PC P4-PC
TB2
Page 24
6 Related Parameters
Coded Output Description
9
A oL1 (Motor overload) 0 1 0 1
B Not used 1 1 0 1
C Uv1, Uv2, Uv3 (Undervoltage) 0 0 1 1
D dEv (Speed deviation) 1 0 1 1
E PGo (PG disconnect) 0 1 1 1
F Not used 1 1 1 1
CPF, oFA, oFb, oFC (Unit hardware fault)
P1-PC P2-PC P3-PC P4-PC
1001
TB2

Parameter Table

Table 7 Related Parameters
No.
(Addr.
Hex)
F5-01
Terminal P1-PC Output Selection
(399)
F5-02
Terminal P2-PC Output Selection
(39A)
F5-03
Terminal P3-PC Output Selection
(39B)
F5-04
Terminal P4-PC Output Selection
(39C)
Name Description Valu es
Sets the function for contact output terminals M1-M2, M3-M4, and photocoupler output terminals P1 through P6.
<1>
When installed to drive Default: 0 Range: 0 to 1A7 When installed to D1000 Default: F Range: 0 to 160
When installed to drive Default: 1 Range: 0 to 1A7 When installed to D1000 Default: F Range: 0 to 160
When installed to drive Default: 2 Range: 0 to 1A7 When installed to D1000 Default: F Range: 0 to 160
When installed to drive Default: 4 Range: 0 to 1A7 When installed to D1000 Default: F Range: 0 to 160
24 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 25
6 Related Parameters
No.
(Addr.
Hex)
F5-05
Terminal P5-PC Output Selection
(39D)
F5-06
Terminal P6-PC Output Selection
(39E)
F5-07
Terminal M1-M2 Output
(39F)
Selection
F5-08
Terminal M3-M4 Output
(3A0)
Selection
F5-09
DO-A3 Output Mode Selection
(3A1)
<1> Refer to the unit Instruction Manual for more information on setting the F5 parameters.
Name Description Valu es
Sets the function for contact output terminals M1-M2, M3-M4, and photocoupler output terminals P1 through P6.
0: Output terminals are each assigned separate output functions. 1: Binary code output 2: Multi-function output (set functions in parameters F5-01 through F5-08)
<1>
When installed to drive Default: 6 Range: 0 to 1A7 When installed to D1000 Default: F Range: 0 to 160
When installed to drive Default: 37 Range: 0 to 1A7 When installed to D1000 Default: F Range: 0 to 160
When installed to drive Default: F Range: 0 to 1A7 When installed to D1000 Default: F Range: 0 to 160
When installed to drive Default: F Range: 0 to 1A7 When installed to D1000 Default: F Range: 0 to 160
When installed to drive Default: 0 Range: 0 to 2 When installed to D1000 Default: 2 Range: 2
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 25
Page 26

7 Troubleshooting

7 Troubleshooting

Unit-Side Error Codes

Table 8 lists the various fault codes related to the option. Refer to the unit instruction manual
for further details on fault codes.
Check the following items first when an error code occurs on the unit:
• Are the cables connected properly and securely?
• Is the option is properly installed to the unit?
• Did a momentary power loss occur?
Table 8 Fault Displays, Causes, and Possible Solutions
Digital Operator Display Fault Name
oFA01
Cause Possible Solution
Option at unit port CN5-A was changed during run.
Digital Operator Display Fault Name
oFb01
Cause Possible Solution
Option at unit port CN5-B was changed during run.
Digital Operator Display Fault Name
oFb02
Cause Possible Solution
Same type of option connected to ports CN5-A and CN5-B.
Digital Operator Display Fault Name
oFC01 Option connection error at unit port CN5-C
Cause Possible Solution
Option at unit port CN5-C was changed during run.
Option Fault (CN5-A)
Option is not properly connected
Turn the power off and check the connectors between the unit and option.
Option Fault (CN5-B)
Option is not properly connected
Turn the power off and check the connectors between the unit and option.
Option Fault (CN5-B)
Two of the same options are connected simultaneously.
Use only compatible options.
Turn the power off and check the connectors between the unit and option.
26 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 27
7 Troubleshooting
Photocoupler
PC
P1 to P6
M1, M3
M2, M4
+V
Contact relay output
Signal
Processor
DO
Digital Operator Display Fault Name
oFC02
Cause Possible Solution
Same type of option connected to unit ports CN5-A, CN5-B, and CN5-C.
Option Fault (CN5-C)
Two of the same options are connected simultaneously.
Use only compatible options.

Preventing Electrical Signal Interference

Take the following steps to prevent erroneous operation caused by electrical signal interference:
• Use shielded wire for the signal lines.
• Limit the length of wiring under 50 m (164 ft.).
• Separate the control wiring to the option, main circuit wiring, and power lines.
Interface Circuit
Figure 11
Figure 11 Output Interface Circuit
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 27
Page 28

8 Specifications

8 Specifications
Table 9 Option Specifications
Item Description
Model DO-A3
Photocoupler Output
Contact Relay Output
Ambient Temperature -10°C to +50°C (14°F to 122°F)
Humidity 95% RH or lower with no condensation
Storage Temperature -20°C to +60°C (-4°F to +140°F) allowed for short-term transport of the product
Area of use Indoor (free of corrosive gas, airborne particles, etc.)
Altitude 1000 m (3280 ft.) or lower
6 outputs (common emitter) Maximum allowable voltage/current: 48 Vdc / 50 mA
2 outputs (independent) Maximum allowable voltage/current: 250 Vac / max.1 A, 30 Vdc / max.1 A
28 YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual
Page 29
8 Specifications
DO
6
5
4
321

Revision History

Revision dates and manual numbers are located on the bottom of the back cover.
MANUAL NO.  TOBP C730600 41B
Published in Japan July 2009 08-7
Date of publication
1
Revision number
Date of original publication
Date of
Publication
August 2012
February 2011
January 2011
July 2010 Back cover Revision: Address
July 2010
July 2009 Chapter 6
July 2008 −−First edition
Revision
Number
Section Revised Content
All Addition: Information on D1000
Back cover Revision: Address
Chapters 3, 4, 5, and
7
Front cover,
back cover
Entire document Edited for procedural clarity and readability.
Back cover Revision: Address
Edited for clarity.
Revision: Format
Correction: Table 5 F5-09 and Output Mode
YASKAWA ELECTRIC TOBP C730600 41E 1000-Series Option DO-A3 Installation Manual 29
Page 30
YASKAWA 1000-Series Option
Digital Output
Installation Manual
DRIVE CENTER (INVERTER PLANT)
2-13-1, Nishimiyaichi, Yukuhashi, Fukuoka, 824-8511, Japan Phone: 81-930-25-3844 Fax: 81-930-25-4369 http://www.yaskawa.co.jp
YASKAWA ELECTRIC CORPORATION
New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minatoku, Tokyo, 105-6891, Japan Phone: 81-3-5402-4502 Fax: 81-3-5402-4580 http://www.yaskawa.co.jp
YASKAWA AMERICA, INC.
2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone: (800) YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310 http://www.yaskawa.com
YASKAWA ELÉTRICO DO BRASIL LTDA.
Avenda Fagundes Filho, 620 Bairro Saude, São Paulo, SP04304-000, Brazil Phone: 55-11-3585-1100 http://www.yaskawa.com.br
YASKAWA EUROPE GmbH
Hauptstrasse 185, 65760 Eschborn, Germany Phone: 49-6196-569-300 Fax: 49-6196-569-398 http://www.yaskawa.eu.com
YASKAWA ELECTRIC UK LTD.
1 Hunt Hill Orchardton Woods, Cumbernauld, G68 9LF, United Kingdom Phone: 44-1236-735000 http://www.yaskawa.co.uk
YASKAWA ELECTRIC KOREA CORPORATION
9F, Kyobo Securities Bldg., 26-4, Yeouido-dong, Yeongdeungpo-gu, Seoul, 150-737, Korea Phone: 82-2-784-7844 http://www.yaskawa.co.kr
YASKAWA ELECTRIC (SINGAPORE) PTE. LTD.
151 Lorong Chuan, #04-01, New Tech Park, 556741, Singapore Phone: 65-6282-3003 http://www.yaskawa.com.sg
YASKAWA ELECTRIC (CHINA) CO., LTD.
12F, Carlton Bld., No.21 HuangHe Road, HuangPu District, Shanghai 200003, China Phone: 86-21-5385-2200 http://www.yaskawa.com.cn
YASKAWA ELECTRIC (CHINA) CO., LTD. BEIJING OFFICE
Room 1011, Tower W3 Oriental Plaza, No. 1 East Chang An Ave., Dong Cheng District, Beijing, 100738, China Phone: 86-10-8518-4086
YASKAWA ELECTRIC TAIWAN CORPORATION
9F, 16, Nanking E. Rd., Sec. 3, Taipei, 104, Taiwan Phone: 886-2-2502-5003
YASKAWA ELECTRIC INDIA PRIVATE LIMITED
#17/A Electronics City, Hosur Road Bangalore 560 100 (Karnataka), India Phone: 91-80-4244-1900 http://www.yaskawaindia.in
Fax: 55-11-5581-8795
Fax: 44-1236-458182
Fax: 82-2-784-8495
Fax: 65-6289-3003
Fax: 86-21-5385-3299
Fax: 86-10-8518-4082
Fax: 886-2-2505-1280
Fax: 91-80-4244-1901
YASKAWA ELECTRIC CORPORATION
In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations. Therefore, be sure to follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply.
Specifications are subject to change without notice for ongoing product modifications and improvements.
© 2008-2012 YASKAWA ELECTRIC CORPORATION. All rights reserved.