YASKAWA DI-A3 Installation Manual

MANUAL NO. TOBP C730600 39A
形式 
DI-A3
取扱説明書
ディジタル入力
安川インバータオプションカード
製品を安全にお使い頂くために,この取扱説明書を必ずお読みください。 また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。
To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual.
Installation Manual
Digital Input
YASKAWA AC Drive-Option Card
Type
DI-A3
This Page Intentionally Blank
YASKAWA E L E C T R I C TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 3
Table of Contents
1 PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2 PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
3 OPTION CARD COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . 8
4 ELECTRICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 9
5 RELATED PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . .19
6 TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
7 SPECIFICATIONS & WARRANTY INFORMATION . . . . . . . 22
Copyright © 2008 YASKAWA ELECTRIC CORPORATION
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
4 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
1 Preface
1 Preface
Yaskawa manufactures products used as components in a wide variety of industrial systems and equipment. The selection and application of Yaskawa products remain the responsibility of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control. Without exception, all controls should be designed to detect faults dynamically and fail safely under all circumstances. All systems or equipment designed to incorporate a product manufactured by Yaskawa must be supplied to the end user with appropriate warnings and instructions as to the safe use and operation of that part. Any warnings provided by Yaskawa must be promptly provided to the end user. Yaskawa offers an express warranty only as to the quality of its products in conforming to standards and specifications published in the Yaskawa manual. NO OTHER WARRANTY, EXPRESS OR IMPLIED, IS OFFERED. Yaskawa assumes no liability for any personal injury, property damage, losses, or claims arising from misapplication of its products.
Applicable Documentation
This instruction manual has been written for the items listed below. Use this option card for its intended purpose only.
Option Card
YASKAWA AC Drive-Option Card Digital Input DI-A3 Installation Manual (this book) Document No. TOBP C730600 39
Read this manual first. It contains information required to install the option card and set up related drive parameters.
Drive
Refer to the manual of the drive this option card is being used with. The manual for the drive covers basic installation, wiring, operation procedures, functions, troubleshooting, and maintenance information. It also includes important information on parameter settings and how to tune the drive. To obtain instruction manuals for Yaskawa products access these sites:
Europe: http://www.yaskawa.eu.com Japan: http://www.e-mechatronics.com Other areas: contact a Yaskawa representative.
1 Preface
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 5
Registered Trademarks
• Company names and product names listed in this manual are the registered trademarks of those companies.
Supplemental Safety Information
Read and understand this manual before installing, operating or servicing this option unit.
The option unit must be installed according to this manual and local codes.
The following conventions are used to indicate safety messages in this manual. Failure to heed these messages could result in serious or possibly even fatal injury or damage to the products or to related equipment and systems.
DANGER
Indicates a hazardous situation, which, if not avoided, will result in death or serious
injury.
W ARNING
Indicates a hazardous situation, which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates an equipment damage message.
1 Preface
6 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
General Safety
General Precautions
• The diagrams in this section may include option units and drives without covers or safety shields to illustrate details. Be sure to reinstall covers or shields before operating any devices. The option board should be used according to the instructions described in this manual.
• Any illustrations, photographs, or examples used in this manual are provided as examples only and may not apply to all products to which this manual is applicable.
• The products and specifications described in this manual or the content and presentation of the manual may be changed without notice to improve the product and/or the manual.
When ordering a new copy of the manual due to damage or loss, contact your Yaskawa
representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover.
DANGER
Heed the safety messages in this manual.
Failure to comply will result in death or serious injury.
The operating company is responsible for any injuries or equipment damage resulting from failure to heed the warnings in this manual.
NOTICE
Do not expose the drive to halogen group disinfectants.
Failure to comply may cause damage to the electrical components in the option unit
Do not pack the drive in wooden materials that have been fumigated or sterilized.
Do not sterilize the entire package after the product is packed.
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 7
2 Product Overview
2 Product Overview
Regarding this Product
Using this option card the drive's frequency reference can be set using binary coded digital inputs.
Checking Package Contents
Table 1 Items Included with this Option Card
• Inspect the Option Card for damage. If the Option Card appears damaged upon receipt,
contact the shipper immediately.
• Verify receipt of the correct model by checking the model number printed on the Name
plate of the Option Card. (see Figure 1)
• If you have received the wrong model or the Option Card does not function properly,
contact your supplier.
Tools Required for Installation
A Phillips screwdriver PH1 (#1) is needed to install this option card.
Additionally a straight-edge screwdriver (blade depth: 0.4 mm, width: 2.5 mm) will be needed to wire the terminal block.
Note: Other tools are required for preparing cables.
Package
Contents
Option Card
Lead Lines
(for grounding)
Screws (M3) Manual (this book)
Number of
Items
1331
MANUAL
8 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
3 Option Card Components
3 Option Card Components
Option Card
Figure 1
Figure 1 Option Card
Terminal Block
Figure 2
Figure 2 Terminal Block
A – Terminal block TB1 E – Model number B – Ground terminal (installation hole) F – Installation hole C – Terminal block TB2 G – Connector (CN-5) D – Terminal block TB3
DI-A3
A
B
CE
D
F
G
Underside
FESDSNSCSPSESI
D7D6D5D4D3D2D1D0
DFDEDDDCDBDAD9D8
TB3
TB2
TB1
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 9
4 Electrical Installation
4 Electrical Installation
Safety Messages
DANGER
Electric Shock Hazard
Power to the drive must be shut off when installing this option card. Even though the power has been shut off, voltage still remains in the drive’s DC bus. Wait before removing the front cover once the drive has been turned off. The CHARGE light on the drive will go out after voltage in the DC bus drops below 50 V, at which point it is safe to remove the front cover. Due to the risk of electric shock, be sure that all LEDs have gone out and that the DC bus voltage has reached a safe level prior to performing any work on the drive.
W ARNING
Electrical Shock Hazard
Do not allow unqualified personnel to perform work on the drive.
Failure to comply could result in death or serious injury.
Maintenance, inspection, and replacement of parts must be performed only by authorized personnel familiar with installation, adjustment and maintenance of AC drives and Option Cards.
4 Electrical Installation
10 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
NOTICE
Damage to Equipment
Observe proper electrostatic discharge procedures (ESD) when handling the option
unit, drive, and circuit boards.
Failure to comply may result in ESD damage to circuitry.
Never shut the power off while the drive is outputting voltage.
Failure to comply may cause the application to operate incorrectly or damage the drive.
Do not operate damaged equipment.
Failure to comply may cause further damage to the equipment. Do not connect or operate any equipment with visible damage or missing parts.
Properly connect all pins and connectors.
Failure to comply may prevent proper operation and possibly damage equipment.
4 Electrical Installation
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 11
Installing the Option Card
Insert the option card in the CN5-A connectors located on the drive’s control board. See the drive manual for directions on removing the front cover.
1. Shut off power to the drive, wait the appropriate amount of time for voltage to
dissipate, then remove the operator and front cover.
2. Insert the CN5 connector on the option card into the matching CN5 connector on
the drive, then fasten it into place using one of the screws included with the option card. Connect one of the lead lines using one of the screws to the ground terminal.
Note: There are only two screw holes on the drive for ground terminals. If three option cards are
connected, two of the lead lines will need to share the same ground terminal.
Figure 3
Figure 3 Installing the Option Card
A – Connector CN5-C G – Mounting screw B – Connector CN5-B H – Lead line C – Connector CN5-A I – Use wire cutters to create an
opening for cable lines D – Drive grounding terminal (FE) J – Front cover E – Insert connector CN5 here K – Digital operator F – Option card L – Terminal cover
H
A
E
F
G
K
B
C
D
I
L
J
4 Electrical Installation
12 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
3. Wire the option card to the terminal block on the option card.
For wiring instructions, see Connection Diagram on page 13. In the drives CIMR-A2A0004 to 0040, 4A0002 to 0023 the cable might need to be routed through the top cover to the outside. In this case cut out the perforated openings at the left side of the drive top cover. Make sure no sharp edges that can damage the cable remain. In the drives CIMR-A2A0056 to 0211, 4A0031 to 0165 the cable can be routed inside the drive.
Figure 4
Figure 4 Wiring space
4. Place the front cover back onto the drive.
Note: 1. Take care when wiring the option card so that the front cover easily fits back onto the drive. Make sure
a cable is not caught between the front cover and the drive when putting the cover back on.
2. The drive will not be used as NEMA Type1 if there is any exposed wiring outside the enclosure.
A – Wires should pass through the
access hold provided on the left side of the front cover. (CIMR-A2A0004 to 0040, 4A0002 to 0023)
B – Use the open space provided
inside the drive to route option card wiring. (CIMR-A2A0056 to 0211, 4A0031 to 0165)
A
B
4 Electrical Installation
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 13
Connection Diagram
Wire terminals on the option card as illustrated in Figure 5.
Refer to Terminal Functions on page 15 for the different functions that can be assigned to the terminals.
Figure 5
Figure 5 Wiring the Option Card and Drive
Take the following steps to prevent erroneous operation caused by noise interference:
• Use shielded wire for the signal lines.
• Keep wiring under 50 m.
• Make sure that control lines to the option card, main circuit wiring, and power lines are separated from one another.
D0 D1
D3
D2
D4 D5 D6
D8
D7
D9 DA DB
DD
DC
DE DF
SI
SP
SE
SC SN
FE
SD
Internal power
Supply wiring
SINK mode
TB2
TB3
TB1
Drive
R/L1 T/L2 S/L3
Lead line
CN5
DI-A3
shielded line
main circuit terminal control circuit terminal
4 Electrical Installation
14 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
SINK Mode
• To use the drive’s internal powers supply, short circuit terminals SP and SC.
• To use an external power supply, connect the positive lead from the power supply to terminal SC on the option card. Do not connect the negative lead to terminal SN on the option card.
SOURCE Mode
• To use the drive’s internal powers supply, short circuit terminals SN and SC.
• To use an external power supply, connect the negative lead from the power supply to terminal SC on the option card. Do not connect the positive lead to terminal SP.
Internal power supply wiring
Photocoupler
Photocoupler
Signal
processor
External power supply wiring
External power supply 24 Vdc
Signal
processor
360Ω
3.3Ω
0 V
24 V
360 Ω
㪊㪅㪊㫂Ω
0 V
24 V
D0〜DF,SI,SE
SC
SN
SP
D0〜DF,SI,SE
SC
SN
SP
Photocoupler
Photocoupler
External
24 Vdc
Internal power supply wiring
External power supply wiring
Signal
processor
D0〜DF,SI,SE
SC
SN
SP
D0〜DF,SI,SE
SC
SN
SP
360 Ω
3.3Ω
0 V
24㩷㪭
360
Ω
3.3Ω
0 V
24 V
Signal
processor
4 Electrical Installation
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 15
Terminal Functions
Table 2 Terminal Function Selection
Termin
al
Block
Termin
al
BCD, Signed
BCD,
Unsigned
Binary, Signed
F3-01 = 0 to 5 F3-01 = 6 <1> F3-01 = 7
8 bit 12 bit 16 bit 16 bit 8 bit 12 bit 16 bit
F3-03 = 0 F3-03 = 1 F3-03 = 2
F3-03
= 0
F3-03
= 1
F3-03
= 2
TB2
D0
<1> The setting F3-01 = 6 is enabled only when F3-03 = 2. Once enabled, the frequency reference can be set from 0.00
to 399.8 Hz with a BCD signal. Because the signed bit SI is also used, a negative reference cannot be input. The smallest bit of the first digit starts with 2, so that 0.02 Hz is the smallest unit that can be used for the frequency reference setting.
1 digit
(0 to 9)
1
1 digit
(0 to 9)
1
1 digits (0 to 9)
1
1 digit
(0 to 9)
2 bit 0 bit 0 bit 0
D1 2 2 2 4 bit 1 bit 1 bit 1
D2 4 4 4 8 bit 2 bit 2 bit 2
D3 8 8 8
2 digits (0 to 9)
1 bit 3 bit 3 bit 3
D4
2 digits
(0 to
15)
1
2 digits
(0 to
15)
1
2 digits (0 to 9)
1 2 bit 4 bit 4 bit 4
D5 2 2 2 4 bit 5 bit 5 bit 5
D6 4 4 4 8 bit 6 bit 6 bit 6
D7 8 8 8
3 digits (0 to 9)
1 bit 7 bit 7 bit 7
TB3
D8
3 digits
(0 to
15)
1
3 digits (0 to 9)
1 2 bit 8 bit 8
D9–224bit 9bit 9
DA 4 4 8 bit 10 bit 10
DB 8 8
4 digits (0 to 9)
1 bit 11 bit 11
DC
4 digits
(0 to
15)
1 2 bit 12
DD 2 4 bit 13
DE 4 8 bit 14
DF 8
5 digits (0 to 3)
1 bit 15
TB1
SI
Signed 0: Forward 1: Reverse
2
Signed 0: Forward 1: Reverse
SE
Set (Read) signal 1: Reads values set to D0 to DF, SI
SP 24 V ±5% internal power supply
SC Input signal common
SN Internal power supply common: 0 V
SD Cable shield 2 (open)
FE Shield ground
4 Electrical Installation
16 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
Input Timing
In order to activate the reference value set by the digital input as frequency reference the controller has to activate the SET input using the timing illustrated in Figure 6. The controller should switch off the SET signal and wait at least 1 ms before the changing digital inputs. After changing the inputs it should wait at least 1 ms before enabling the SET signal. The SET signal should be activated for at least 3 ms.
Figure 6
Figure 6 SET Input Timing
D0DF SIGN data
SET input timing
1 ms min. 3 ms min.
(SET is switched on)
Setting value change Setting value change
1 ms min.
Reads setting
4 Electrical Installation
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 17
Wire Gauges and Tightening Torque
Wire gauge specifications are listed below in Table 3. Yaskawa recommends using crimp terminals for easy of wiring and to ensure proper connection. Crimp terminal specifications can be found in Table 4.
Table 3 Wire Gauges and Tightening Torque
Crimp Terminals
Yaskawa recommends using CRIMPFOX ZA-3 by Phoenix Contact to crimp the terminal ends.
Note: Wire ends should be properly trimmed so no wire extends out from the crimp terminals.
Table 4 Crimp Terminal Sizes
Terminal
Signal
Screw
Size
Tightening
Torque
(Nxm)
Bare Cable
Wiring Gauges with
Crimp Terminals
Wire Type
Possible
Gauges
mm
2
(AWG)
Recom
mended
Gauges
mm
2
(AWG)
Possible
Gauges
mm
2
(AWG)
Recom
mended
Gauges
mm
2
(AWG)
D0 to DF, SI,SE,SP,
SC,SN,FE
M2 0.22 to 0.25
Stranded wire:
0.25 to 1.0 (24 to 17)
Single line:
0.25 to 1.5 (24 to 16)
0.75 (18)
0.25 to 0.5 (24 to 20)
0.5
(20)
Shielded
twisted pair,
etc.
Wire Gauge
mm
2
(AWG)
Model
L
(mm)
d1
(mm)
d2
(mm)
Manufacturer
0.25 (24) AI 0.25 - 6YE 10.5 0.8 2
Phoenix Contact0.34 (22) AI 0.34 - 6TQ 10.5 0.8 2
0.5 (20) AI 0.5 - 6WH 14 1.1 2.5
d1
d2
6 mm
L
4 Electrical Installation
18 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
Wiring Procedure
When wiring the option card, wire ends should be prepared as shown in Figure 7. See Wire
Gauges and Tightening Torque on page 17 to make sure the proper tightening torque is
applied to each terminal end.
Take particular precautions to ensure that each cable is properly connected, and that wire insulation has not been accidentally inserted into the terminals.
NOTICE: Insulation or tape may be required to ensure that shielded lines do not come into contact with other wiring. Insufficient insulation may cause a short circuit that can damage the option card and the drive.
NOTICE: Follow the tightening torque specifications in this manual for all terminal screws. Failing to do so may keep the drive from functioning properly and could damage the terminal block.
Figure 7
Figure 7 Treating Terminal Ends for Shielded Line
Figure 8
Figure 8 Terminal Block Wiring
Insulation
Shield shearth (Insulate with tape)
Shield
Option Card
PG
FE/SD
Insulation
Shield sheath (Insulate with tape)
Shield
Option Card
External device
FE/SD
Blade depth of
0.4 mm or less
Avoid fraying wire stands when stripping insulation from wire.
Blade width of
2.5 mm or less
Strip length 5.5 mm
Terminal block
Loosen screw to insert wire.
Single wire or stranded wire
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 19
5 Related Parameters
5 Related Parameters
The following parameters are used to set up the drive for operation with an option card. Set parameters as needed. Instructions on how to set parameters can be found in the instruction manual for the drive the option card is connected to.
Table 5 Related Parameters
No.
<1> Binary input is not possible if o1-03 is set to 2 or 3. The setting of F3-01 will be disregarded and setting units
will be determined by o1-03.
<1>
Parameter Name Description
Setting
Range
Default
F3-01
<1>
Option Card Input Selection
Selects the method to input the option card data. 0: BCD 1% unit 1: BCD 0.1% unit 2: BCD 0.01% unit 3: BCD 1 Hz unit 4: BCD 0.1Hz unit 5: BCD 0.01Hz unit 6: BCD custom setting (5 digit input), 0.02 Hz units 7: Binary input
0 to 7 0
F3-03
Data Length Selection
0: 8 bit 1: 12 bit 2: 16 bit
0 to 2 2
20 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
6 Troubleshooting
6 Troubleshooting
Error Codes Displayed on the Drive Operator
The table below lists the various fault codes related to this option card. Further detail on various faults can be found in the instruction manual for the drive.
• Check all cables connected to the option card.
• Make sure the option card is properly installed to the drive.
Table 6 Fault Display
Digital Operator Display Fault Name
oFA01 Option Card Connection Error at CN5-A
Cause Possible Solution
Option card at port CN5-A was changed during run.
Switch the power off and reconnect the option card.
Digital Operator Display Fault Name
oFb01 Option Card Connection Error at CN5-B
Cause Possible Solution
Option card at port CN5-B was changed during run.
Switch the power off and reconnect the option card.
Digital Operator Display Fault Name
oFb02 Duplicate Option at Port CN-B
Cause Possible Solution
Same type of option card connected to ports CN5-A and CN5-B.
Use only compatible option cards. See note
<1>.
Digital Operator Display Fault Name
oFC01 Option Card Connection Error at CN5-C
Cause Possible Solution
Option card at port CN5-C was changed during run.
Switch the power off and reconnect the option card.
Digital Operator Display Fault Name
oFC02 Duplicate Option Connected
Cause Possible Solution
Same type of option card connected to ports CN5-A, CN5-B, and CN5-C.
Use only compatible option cards. See note
<1>.
6 Troubleshooting
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 21
Table 7 Option Card Installation
Digital Operator Display Fault Name
oPE05 Run Command/Frequency Reference Source Selection Error
Cause Possible Solutions
Frequency reference is assigned to an option card (b1-01 = 3) but an input option card is not connected to the drive.
Reconnect the input option card to the drive.
<1> Depending the type of option card, only a certain number of cards may be connected at the same time. Refer to
table below. More details can be found in the option card section of the drive instruction manual.
Option Card
<2> The AI-A3 and DI-A3 option can also be installed to option ports CN5-B and CN5-C, but are then used for
monitoring purposes only. Input levels are then displayed in U1-17, U1-21 to U1-23. Here, the option cards cannot be used to set the frequency reference or replace the drive analog input with higher resolution inputs.
<3> If only one PG option card is connected to the drive, use the CN5-C connector. If two PG option cards are
connected, use both CN5-B and CN5-C.
Connector Number of Cards Possible
SI-C3, SI-N3, SI-P3, SI-S3, AI-A3, DI-A3
<2>
CN5-A 1
PG-B3, PG-X3 CN5-B, C 2
<3>
DO-A3, AO-A3 CN5-A, B, C 1
22 YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual
7 Specifications & Warranty Information
7 Specifications & Warranty Information
Specifications
Table 8 Specifications
Model DI-A3
Digital Input 18 Terminals (including SET and SIGN signals)
Input Signal Type
(Parameter
Settings)
Binary 16 bit, 4 digit BCD Binary 12 bit, 3 digit BCD Binary 8 bit, 2 digit BCD
Input Signal
Sink, source, external power supply Photocoupler input: 24 Vdc, 8 mA
Ambient
Temperature
–10°C to 50°C
Humidity 95% RH or less with no condensation
Storage
Temperature
–20°C to 60°C allowed for short-term transport of the product
Area of Use Indoor (free of corrosive gas, airborne particles, etc.)
Altitude 1000 m or less
7 Specifications & Warranty Information
YASKAWA ELECTRIC TOBP C730600 39A YASKAWA AC Drive-Option Card DI-A3 Installation Manual 23
Revision History
The revision dates and numbers of the revised manuals are given on the bottom of the back cover.
Date of
Publication
Rev.
No
Section Revised Content
July 2008 −−First edition
MANUAL NO.  TOBP C730600 39A
Published in Japan July 2008 08-7
Date of publication
Date of original publication
YASKAWA ELECTRIC CORPORATION
In the event th at the end us er of t his produc t i s to be th e milit ary an d s aid pro duc t is to be employe d i n an y we apo ns syst ems or the ma nufa ctur e the reof, th e ex por t will fal l u nder th e r eleva nt regu lat ions as st ipulate d i n the Forei gn Exchang e a nd Foreign Trade Re gul ations. T her efor e, b e sure to follow a ll proc edu res and su bmit al l r eleva nt documen tat ion acc ord ing to any and al l r ules , r egul ati ons and laws t hat may app ly.
Spe cifi cat ions ar e s ubject to change wit hout no tic e fo r ongoi ng product mo dificat ion s and i mpr ovements .
© 20 08 YASKAWA ELECTRI C C ORPORATION . All ri ght s r eser ved.
YASKAWA
IRUMA BUSINESS CENTER (SOLUTION CENTER)
480, Kamifujisawa, Iruma, Saitama 358-8555, Japan Phone 81-4-2962-5696 Fax 81-4-2962-6138
YASKAWA ELECTRIC AMERICA, INC.
2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone 1-847-887-7000 Fax 1-847-887-7370
YASKAWA ELETRICO DO BRASIL LTDA.
Avenida Fagundes Filho, 620 Sao Paulo-SP CEP 04304-000, Brazil Phone 55-11-3585-1100 Fax 55-11-5581-8795
YASKAWA ELECTRIC EUROPE GmbH
Hauptstraβe 185, 65760 Eschborn, Germany Phone 49-6196-569-300 Fax 49-6196-569-398
YASKAWA ELECTRIC UK LTD.
1 Hunt Hill Orchardton Woods Cumbernauld, G68 9LF, United Kingdom Phone 44-1236-735000 Fax 44-1236-458182
YASKAWA ELECTRIC KOREA CORPORATION
7F, Doore Bldg. 24, Yeoido-dong, Youngdungpo-Ku, Seoul 150-877, Korea Phone 82-2-784-7844 Fax 82-2-784-8495
YASKAWA ELECTRIC (SINGAPORE) PTE. LTD.
151 Lorong Chuan, #04-01, New Tech Park 556741, Singapore Phone 65-6282-3003 Fax 65-6289-3003
YASKAWA ELECTRIC (SHANGHAI) CO., LTD.
No.18 Xizang Zhong Road. Room 1702-1707, Harbour Ring Plaza Shanghai 200001, China Phone 86-21-5385-2200 Fax 86-21-5385-3299
YASKAWA ELECTRIC (SHANGHAI) CO., LTD. BEIJING OFFICE
Room 1011A, Tower W3 Oriental Plaza, No.1 East Chang An Ave., Dong Cheng District, Beijing 100738, China Phone 86-10-8518-4086 Fax 86-10-8518-4082
YASKAWA ELECTRIC TAIWAN CORPORATION
9F, 16, Nanking E. Rd., Sec. 3, Taipei, Taiwan Phone 886-2-2502-5003 Fax 886-2-2505-1280
08-5-3
Published in Japan July 2008 08-7
MANUAL NO. TOBP C730600 39A
Installation Manual
Digital Input
YASKAWA AC Drive-Option Card
Loading...