Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc.
could void the user's authority to operate the equipment.
IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and
security of this product. Misalignment can cause performance degradation and a lessening of
security.
Finish Care: This lockset is designed to provide the highest standard of product quality and
performance. Care should be taken to ensure a long-lasting finish. When cleaning is required
use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes
could damage the coating and result in tarnishing.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful Interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
2
An ASSA ABLOY Group brand
P/N AYRD210-INST-FUL Rev B
Page 3
To Ensure Proper Lock Handing and for an explanation
of how to determine your lock handing, please read this
important note.
IMPORTANT: Do not install batteries until the lock is completely installed on door.
For your convenience, the Yale Real Living lock will automatically determine
whether it will function as a right or left-handed lock. (The "hand" or "handing"
of the lock, is determined by the side of the entry door that the hinges are on
when standing outside the door)
When the batteries are properly inserted for the first time, the lock will attempt
to determine its handing - whether the lock is installed on the door or not. If the
lock is not completely installed on the door, it could hand itself incorrectly.
Should this occur, the lock must be installed on the door and then reset to its
factory defaults, allowing the lock to "hand" itself correctly.
To reset the lock to factory default, see the following:
Reset Lock to Factory Default
The following procedure clears the automatic handing of the
lock and returns the lock to programming default - deleting
all user codes and setting the Master PIN code* back to the
default ("12345678").
1. Remove the batteries and then remove the inside escutcheon
to access the reset button.
2. The reset button (see image at right) is located above the
PCB cable connector.
3. Hold down the reset button for a minimum of 3 seconds and
then reinstall the batteries; once the batteries are properly
installed, release the reset button.
4. Reassemble the lock by reversing the same steps on page 6.
All features should now be returned to factory default.
*The default Master PIN code must be changed prior to programming of the lock.
Reset Button
Cable
Inside Escutcheon
An ASSA ABLOY Group brand
3
P/N AYRD210-INST-FUL Rev B
Page 4
Industry Canada:
Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)
Model(s): YRDZW, YRDZB
This Class B digital apparatus meets all requirements of the Canadian Interference Causing
Equipment Regulations. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne
causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce
dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle
interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:
“This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm between
the radiator and your body. This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.”
Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne
d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour
réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies
de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire
pour une communication réussie.
Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s).
Operation is subject to the following two conditions: 1) this device may not cause interference, and 2)
this device must accept any interference, including interference that may cause undesired operation of
the device.
Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son
fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des
interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
causer un mauvais fonctionnement du dispositif.
The Yale Real Living™ Stand-alone Push Button Deadbolt Lock combines a robust lockset with a
contemporary electronic aesthetic.
Users benefit from a push button keypad that makes day-to-day access effortless for simple updates
to user information in the event of staffing changes or security breaches. Yale Real Living™ is engineered for quick and easy installation and fits in place of a standard deadbolt lock door prep (ANSI/
BHMA A156.115).
If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network
controller. That distance is influenced by objects between the lock and the controller and may be
expanded depending on proximity to other RF network devices. Also, if the lock is connected to a
network controller, it is recommended that it is programmed through the centralized user interface
(PC or hand-held device) to ensure communication between the lock and the controller unit.
An ASSA ABLOY Group brand
INTRODUCTION
4
P/N AYRD210-INST-FUL Rev B
Page 5
Included in the box. . .
INSTALLATION
COMPONENTS AND TOOLS
Quick Start Guide
Installation Instructions
Door Marker
Outside Escutcheon
Parts Illustrations
Inside Escutcheon
Inside Mounting Plate
Battery Cover
4 AA Alkaline Batteries
Bolt
Strike Plate
Screw Pack
Keys
Bolt
Battery Cover
Outside
Escutcheon
(2) Through
bolts
Tools Needed
Door Prep
2-1/8" (54mm) hole saw
1" (26mm) boring bit
7/64" (2.5mm) drill bit
Chisel & hammer
An ASSA ABLOY Group brand
Inside
Escutcheon
Keys
Inside
Mounting
Plate
(3) Inside Escutcheon
Mounting screws
Lock Installation
#2 Phillips screwdriver
4 AA Alkaline
Batteries
Network Module
(Optional)
Strike Plate
(4) Bolt & Strike Plate
Mounting Screws
5
P/N AYRD210-INST-FUL Rev B
Page 6
PREPARE LOCK FOR INSTALLATION
Unpack the Lock
The lock is packed representative of how it will install on
the door.
Before installing the lock on the door:
A. Inside escutcheon
1. Loosen the screw (Phillips #2) holding the battery
cover. (The screw remains attached to battery
cover)
2. Slide the battery cover up and out (note the two tabs
at bottom of battery cover).
3. Remove the inside mounting plate (with gasket) from
the back (door side) of the inside escutcheon.
a. Ensure that gasket
on Inside Mounting
Plate is properly
fitted. Note the
positioning of the
gasket's five rubber
nubs (Figure 3A) .
Battery Cover
2
Inside Escutcheon
1
Inside Escutcheon & Mounting Plate
(with gasket)
3
B. Bolt
Note: Bolt ships with backset in 2-3/8" position. If required, press small black button on
underside of bolt and pull to extend to 2-3/4"
backset position.
C. The outside escutcheon (with gasket) remains assembled.
Figure 3A
Detail 3B1
Figure 3B
Outside Escutcheon
An ASSA ABLOY Group brand
6
P/N AYRD210-INST-FUL Rev B
Page 7
INSTALL LOCK
1. Install bolt in door.
NOTE: The bolt must be in a retracted (unlocked) position
when installing the lockset.
Attach with (2) M4 x 25.4mm [8-32 x 1"] screws supplied.
2. Install strike on the door frame, making sure to allow
for the bolt to be centered in the strike.
3. Install outside escutcheon.
As you position the outside escutcheon, route the
cable through 2-1/8" diameter hole (Figure 3A).
NOTE: Cable goes under bolt (see Fig. 3B).
1
(2) M4 x 25.4mm
[8-32 x 1"]
Flat Head
Combination Screws
2
(2) M4 x 25.4mm
[8-32 x 1"]
Flat Head
Combination Screws
4. Holding the outside escutcheon flush to the door,
position the inside mounting plate by first routing
the cable and connector through the mounting
plate's 1/2" hole (Fig. 4A) and then inserting the
mounting plate “tongue“ into the bottom slot of the
outside escutcheon (Fig. 4B).
“Tongue”
Figure 4A
Figure 3A
Figure 3B
An ASSA ABLOY Group brand
Figure 4B
7
P/N AYRD210-INST-FUL Rev B
Page 8
5. Secure both assemblies using (2) M6 x 59.5mm
pan head machine screws, making sure that
outside escutcheon is vertically aligned.
Hand-tighten until snug. Do not over-tighten.
CAUTION:
Use care when assembling to ensure that
the cable lies against the back recessed
area of the inside escutcheon (Fig. 6A).
Position and bend cable, using the harness
clip as shown in Fig. 6A to prevent binding
when installing the escutcheon over the
mounting plate.
6. Attach cable assembly to the inside escutcheon
PC board by lining up notches on top of cable
connector to slots on PCB connector (Fig. 6B).
Note that connector should be pressed in firmly using thumbs until completely seated (proper position
indicated by arrows on PCB as in Fig. 6A & 6B ) .
Route cable
as indicated -
do not cover
hole
Harness
clip
Figure 6A
Figure 6B
7. Install inside escutcheon on inside mounting
plate. Note the horizontal orientation of the tail-
piece (Fig. 7A) as you insert the inside escutcheon
(thumb turn should be vertical).
8. Install and secure using (3) M4 x 8mm [8-32 x 5/16"]
pan head screws through the inside escutcheon into
the mounting plate.
IMPORTANT: Before installing the batteries, test
the mechanical operation of the lock by using
both thumb turn and the key. The movement of the
bolt should be smooth and unobstructed. If
operation is not smooth, review the previous steps
to ensure proper installation.
9. Insert four (4) AA alkaline batteries. The lock responds
with a series of beeps, a red/blue flash and a quick flash
of all keypad LEDs. When activating the lock for the
first time, the lock will adjust for proper handing.
Figure 7A
Note: Refer to programming instructions prior to completion of
step 10.
10. Install battery cover and tighten Phillips head screw.
An ASSA ABLOY Group brand
8
P/N AYRD210-INST-FUL Rev B
Page 9
PROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONS
Outside
Status Indicator
Menu and Icons Used in This Guide
Numbers
Cylinder
Inside
Phillips Screw
Battery Cover
Network Module Slot
Alkaline Batteries
4 AA Type
Status Indicator
Thumb Turn
Privacy Mode Button
~
Status Indicators
Low Battery Warning
1
Click the indicated number.
Press the Starkey on the keypad to Enter
or Acceptentry.
Press the Pound key on the keypad to
enter Menu mode.
Lock-out Mode
2
RED
M
Enter Master PIN code (4-8 digits in
length).
(Factory default: 12345678)
U
Enter User PIN. Can be 4-8 digits in
length.
User Number (1 - 25);
RF Controlled (1 - 250).
Return to previous step
3
RED &
BLUE
BLUE
An ASSA ABLOY Group brand
9
P/N AYRD210-INST-FUL Rev B
Page 10
Definitions
Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all
user PIN code access. When attempting to enter a code while the unit is in Lockout, the
Status Indicator flashes RED and BLUE; the keypad flashes as well.
Low Battery: When battery power is low, the Status Indicator flashes RED. If battery
power is completely lost, use the key override.
Master PIN Code: The Master code is used for programming and for feature settings.
NOTE: The default Master Pin Code must be changed prior to programming the
lock. The Master code will also operate the lock.
Privacy Mode: This button located under the thumb turn on the inside escutcheon, ac-
tivates and deactivates the keypad and is indicated by a BLUE flash every ten (10) seconds. It is also overridden by mechanically operating the thumb turn or key.
Auto Re-lock Time: After successful code entry and the unit unlocks, it will automatically
re-lock after a default of thirty (30) seconds. Re-lock time is adjustable from five (5) to
thirty (30) seconds.
One Touch Re-Lock: When the bolt is retracted, activating the keypad will extend the bolt
(during Auto Re-Lock duration or when Auto Re-Lock is disabled).
Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow
operation after the wrong code entry limit has been met. When the unit is in Shutdown,
the Status Indicator flashes RED and BLUE; the keypad flashes as well.
Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone
playback for use in quiet areas. Audio mode is enabled or disabled through feature programming by the Master code.
Status LED: Located on inside escutcheon.
User PIN Code: The User code operates the lock. Maximum number of user codes is
250 with Network Module; without Network Module, maximum is 25 user codes.
Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering
a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is
adjustable from three (3) to ten (10) times through feature settings (up to 5 times with no
RF network enabled - default is 5; 10 with RF network enabled).
Factory Defaults
SettingsFactory Defaults
Master Code12345678
Auto Re-lockEnabled
AudioEnabled
Re-lock Time*30 Seconds
Wrong Code Entry Limit*5 Times
Shutdown Time*60 Seconds
*Adjustable with Network Module
An ASSA ABLOY Group brand
10
P/N AYRD210-INST-FUL Rev B
Page 11
Lock Operation
Change Default Master Code Before Programming*
1. Enter the 8-digit default Master PIN code (12345678) followed by the key.
2. Enter “1” followed by the key.
3. Enter new 4-8 digit Master PIN code followed by the key.
*Default Master PIN Code must be changed prior to programming the lock.
1
1
Enter current Master PIN code,
followed by the
key.
2
Enter '1' to change Master PIN code,
followed by the key.
3
Enter the new Master PIN code (4~8
digits), followed by the
PIN code structure
Maximum number of user codes is 250 with Network Module; without Network Module,
maximum is 25 user codes.
Set Up User Codes
User Codes can only be programmed through the Master Code.
1. Enter the 4-8 digit Master PIN code followed by the key.
2. Enter “2“ followed by the key.
3. Enter the User number to be registered (1-25) followed by the key.
4. Enter a 4-8 digit PIN code for the User number followed by the key.
key.
Note: When registering User codes, the code must be entered with in 20 seconds.
If time expires, no codes are registered and the process must be re-started.
Privacy Mode vs. Lockout Mode
Lockout is a Menu feature that restricts Pin code access (except Master).
Privacy mode is set by pressing and holding the button (found below thumb turn) for a
duration of four beeps. This deactivates the keypad, and because it is set from the inside,
provides a secure lock for the convenience of the occupant(s).
An ASSA ABLOY Group brand
11
P/N AYRD210-INST-FUL Rev B
Page 12
Open Door with PIN Code
1
Enter PIN code.
2
Complete the code entry
3
Unlock.
by pressing the key.
Feature Programming Through Menu Mode Using Master Code
1. Enter the 4-8 digit Master PIN code followed by the key.
2. Enter digit corresponding to the function to be performed followed by the key.
Note: If the lock is connected to a network controller, it is recommended that it is
programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.
12
M
Master PIN Setting
User PIN Registration
User PIN Deletion
Auto Re-lock
Audio Mode
All Code Lock-out
M
Enable
Disable
Enable
Disable
Enable
Disable
User Number (UN)
1~25: without network module
1~250: with network module
U
Complete
Complete
For quiet areas, select Disable (3)
in Audio Mode.
*Network Module Setting
7
*This function appears
only with network module
installed
An ASSA ABLOY Group brand
Register
Delete
CAUTION: When joining a network your controller may or may not
be aware of any previously saved user codes stored in the lock. It is
recommended that all user codes be deleted from the lock prior to
joining a network.
Cycle the lock in both the locked and the unlocked positions. If problems are found:
Door is bindinga. Check that door and frame are properly aligned and door is free swinging.
Bolt will not deadlocka. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing
Bolt does not extend or retract smoothly a. Bolt and strike are misaligned, see above.
SymptomSuggested Action
b. Check hinges: They should not be loose or have excessive wear on knuckles.
the depth of the pocket for the bolt.
b. Check for misalignment of bolt and/or strike which may be preventing bolt from properly
entering the strike. With the door open, extend and retract the bolt; if it is smooth, check the
strike alignment.
b. Check the backset of door relative to adjustments already made to bolt.
c. Verify proper door preparation and re-bore holes that are too small or misaligned.
d. Verify keypad cable/connector is routed under the bolt (see Fig. A).
e. Verify bolt is installed correct side up (Fig. A). .
Figure A
Yale Real Living™ locks are automatically handed. On startup, hold down the reset button
and wait while the lock tests bolt operation. The default Master Pin Code must be changed
before any other programming.
An ASSA ABLOY Group brand
13
P/N AYRD210-INST-FUL Rev B
Page 14
Programming Troubleshooting
SymptomSuggested Action
Lock does not respond – door is
open and accessible.
•Press each keypad button to see if they respond when pressed.
•Check batteries are installed and oriented correctly (polarity) in the battery case.
•Check batteries are in good condition; replace batteries* if discharged.
•Check to see if cable is fully connected and not pinched.
Lock does not respond – door is
locked and inaccessible.
•Lock may be in Privacy mode (set from inside room). Mechanical key will grant access.
•Batteries may be completely discharged.
•Use mechanical key to gain entry and replace batteries*.
Unit chimes to indicate code acceptance, but the door will not open.
•Check to see if there is another locking device on the door.
•Check the door gaps for any foreign objects between door and frame.
•Check that the cable is firmly connected to the PC board.
Unit operates to allow access, but will
not automatically re-lock.
•Check to see if Auto Re-lock Mode is enabled.
•Disable Auto Re-lock Mode to lock the door (automatically).
•If low battery indicator is lit (see below), change batteries*.
PIN codes will not register.•PIN codes must consist of 4 to 8 digits to register.
•The same PIN code cannot be used for multiple users.
•Registration/management of PIN codes is set by the authority of the Master Code.
•Contact the Master user
•User codes must be entered within 20 seconds or the process will have to be restarted.
•The star (*) or pound (#) cannot be used as part of the PIN code.
Upon entering a PIN code and pressing the star (*) key, the lock gives
a series of beeps, flashes red and
blue LEDs seven times, and does not
•Lockout Mode is enabled.
•Only the Master can enable/disable Lockout Mode.
•Contact the Master user.
unlock.
Upon entering a PIN code and pressing the (*) key, there are different
tones.
•Check to see if the lock is set to Lockout Mode.
•Setting/managing Lockout Mode is done through Master Code only. Contact the Master
user.
The unit operates, but it makes
no sound.
The unit displays intermittent RED
flashes.
Upon entering a PIN code and pressing the star (*) key, the unit responds
with a series of beeps and the keypad
flashes three times.
* When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface (UI); it
is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).
** Network Module locks only
An ASSA ABLOY Group brand
•Enable Audio Mode.
•This is the Low Battery indicator alerting that it is time to replace the batteries. Replace
all four (4) batteries* with new AA Alkaline batteries.
•The digits entered were incorrect or incomplete. Re-enter the correct code followed by
the star key.
14
P/N AYRD210-INST-FUL Rev B
Page 15
Installing the Network Module
IMPORTANT: The batteries must be removed prior to removing and/or inserting the
network module:
• Remove batteries
• Remove and/or insert network module
• Reinstall batteries
Use feature programming step 7 (page 13) for enrollment of the
Network Module.
An ASSA ABLOY Group brand
15
P/N AYRD210-INST-FUL Rev B
Page 16
How to Replace or Install Cylinder
1. Remove cylinder:
A. Remove outside escutcheon from door.
B. Remove rubber gasket.
C. Remove two screws holding plastic guide
in place.
D. Remove plastic guide.
E. Remove screw with washer holding cylinder in
place (visible after plastic guide is removed).
F. Remove cylinder by pulling towards the
door side of escutcheon.
Before installing cylinder, please be sure you have
correct length tailpiece.
2. Install new cylinder:
A. Reverse previous steps for removing cylinder.
D
A
B
Cylinder tailpiece information:
L
*Requires addition of Thin Door Kit.
C
E
F
1-3/8"* to 2" thick doors, L = 3-1/2" (88.8mm)
2" to 2-1/4" thick doors, L = 3-3/4" (95.3mm)
Tailpiece
T = .098" (2.5mm)
w
T
W = .2" (5.2mm)
16
An ASSA ABLOY Group brand
P/N AYRD210-INST-FUL Rev B
Page 17
PIN CODE MANAGEMENT SAMPLE SHEETS
PIN Code Management (No Network Module - Up to 25 Users)
Location: Door Number:
User TypeUser NameUser #PIN Code
MasterUser 13
User 1 User 14
User 2User 15
User 3User 16
User 4User 17
User 5User 18
User 6User 19
User 7User 20
User 8User 21
User 9User 22
User 10User 23
User 11User 24
User 12User 25
UserUser NameUser #PIN Code
An ASSA ABLOY Group brand
17
P/N AYRD210-INST-FUL Rev B
Page 18
PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries
User TypeUser NameUser #PIN CodeUserUser NameUser #PIN Code
MasterUser ___
User ___User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
User ___ User ___
18
An ASSA ABLOY Group brand
P/N AYRD210-INST-FUL Rev B
Page 19
ONLINE LITERATURE AND TEMPLATES
For the latest information on Yale products visit our website at
www.yalelocks.com. Click on the “Literature” button to find the
most up-to-date catalogs, parts manuals, templates, specifications and installation instructions.