Yale YRDZB, YRD210-ZB, YRD220-ZB, YRT210-ZB, YRT220-ZB Installation And Programming Instructions

Certification Exhibit
FCC ID: U4A-YRHCPZB0
IC: 6982A-YRHCPZB0
FCC Rule Part: 15.247
ACS Project Number: 12-0001
Manufacturer: Assa Abloy Inc.
Models: YRDZB, YRD210-ZB, YRD220-ZB, YRT210-ZB, YRT220-ZB
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Manual – YRD220-ZB
Yale Real Living™ Touchscreen Deadbolt
Installation and Programming Instructions
NOTE TO INSTALLER
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY
For Technical Assistance call Yale at 1-800-810-WIRE (9473)
This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com.
Click “Product Information & Documentation” and then “Installation Instructions”.
Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com.
Presione “Información del Producto y Documentación” y luego “Instrucciones de Instalación”.
Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com.
Cliquez sur le “ ; Information sur le produit et Documentation” et puis “Installation Instructions”.
An ASSA ABLOY Group brand
P/N AYRD220-INST-FUL Rev B
TABLE OF CONTENTS
Warnings .........................................................................................................................2
Reset Lock to Factory Default ..................................................................................3
Introduction .....................................................................................................................4
Installation
Components and Tools .............................................................................................5
Prepare Lock for Installation .....................................................................................6
Install Lock ............................................................................................................ 7-8
Programming
Programming Features-Menu Keys-Definitions ................................................. 9-10
Operation .......................................................................................................... 11-13
Miscellaneous Information
Hardware Troubleshooting ......................................................................................14
Programming Troubleshooting ...............................................................................15
Installing the Network Module ................................................................................16
Replace/Install Cylinder ..........................................................................................17
Sample Pin Code Management Sheets ........................................................... 18-19
WARNINGS
Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc. could void the user's authority to operate the equipment.
IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and security of this product. Misalignment can cause performance degradation and a lessening of security.
Finish Care: This lockset is designed to provide the highest standard of product quality and performance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coating and result in tarnishing.
FCC:
FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee) Model(s): YRD220-ZW, YRD220-ZB This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
2
An ASSA ABLOY Group brand
P/N AYRD220-INST-FUL Rev B
To Ensure Proper Lock Handing and for an explanation of how to determine your lock handing, please read this important note.
IMPORTANT: Do not install batteries until the lock is completely installed on door.
For your convenience, the Yale Real Living lock will automatically determine whether it will function as a right or left-handed lock. (The "hand" or "handing" of the lock, is determined by the side of the entry door that the hinges are on when standing outside the door)
NOTE: The bolt must be in a retracted (unlocked) position when installing the lockset and before batteries are installed.
When the batteries are properly inserted for the first time, the lock will attempt to determine its handing - whether the lock is installed on the door or not. If the lock is not completely installed on the door, it could hand itself incorrectly.
Should this occur, the lock must be installed on the door and then reset to its factory defaults, allowing the lock to "hand" itself correctly.
To reset the lock to factory default, see the following:
Reset Lock to Factory Default
The following procedure clears the automatic handing of the lock and returns the lock to programming default - deleting all user codes and setting the Master PIN code* back to the default ("12345678").
1. Remove the batteries and then remove the inside escutcheon to access the reset button.
2. The reset button (see image at right) is located above the PCB cable connector.
3. Hold down the reset button for a minimum of 3 seconds and then reinstall the batteries; once the batteries are properly installed, release the reset button.
4. Reassemble the lock by reversing the same steps on page 6.
All features should now be returned to factory default.
*The default Master PIN code must be changed prior to programming of the lock.
Reset Button
Cable
Inside Escutcheon
An ASSA ABLOY Group brand
3
P/N AYRD220-INST-FUL Rev B
Industry Canada:
Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee) Model(s): YRD220-ZW, YRD220-ZB
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:
“This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”
Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.
The Yale Real Living™ Stand-alone Touchscreen Deadbolt Lock combines a robust lockset with a contemporary electronic aesthetic.
Users benefit from an interactive touchscreen that makes day-to-day access effortless, as well as offering voice-guided programming for simple updates to user information in the event of staffing changes or security breaches. Yale Real Living™ is engineered for quick and easy installation and fits in place of a standard deadbolt lock door prep (ANSI/BHMA A156.115).
If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network controller. That distance is influenced by objects between the lock and the controller and may be expanded depending on proximity to other RF network devices. Also, if the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.
An ASSA ABLOY Group brand
INTRODUCTION
4
P/N AYRD220-INST-FUL Rev B
Included in the box. . .
INSTALLATION
COMPONENTS AND TOOLS
Quick Start Guide
Installation Instructions
Door Marker
Outside Escutcheon
Parts Illustrations
Inside Escutcheon
Inside Mounting Plate
Battery Cover
4 AA Alkaline Batteries
Bolt
Strike Plate
Screw Pack (see below)
Keys
Bolt
Battery Cover
Outside
Escutcheon
(2) Through
bolts
Tools Needed
Inside
Escutcheon
(3) Inside Escutcheon
Mounting screws
Door Prep
2-1/8" (54mm) hole saw
 1" (26mm) boring bit
 7/64" (2.5mm) drill bit
Chisel & hammer
An ASSA ABLOY Group brand
Inside
Mounting
Plate
Keys
Lock Installation
#2 Phillips screwdriver
4 AA Alkaline
Batteries
Network Module (Optional)
Strike Plate
(4) Bolt & Strike Plate Mounting Screws
5
P/N AYRD220-INST-FUL Rev B
PREPARE LOCK FOR INSTALLATION
Unpack the Lock
The lock is packed representative of how it will install
on the door.
Before installing the lock on the door:
A. Inside escutcheon
1. Loosen the screw (Phillips #2) holding the battery cover. (The screw remains attached to battery cover)
2. Slide the battery cover up and out (note the two tabs at bottom of battery cover).
3. Remove the inside mounting plate (with gasket) from the back (door side) of the inside escutcheon.
a. Ensure that gasket
on inside mounting plate is properly fitted. Note the positioning of the gasket's five rubber nubs (Figure 3A) .
Battery Cover
2
Inside Escutcheon
1
Inside Escutcheon & Mounting Plate (with gasket)
3
B. Bolt
Note: Bolt ships with backset in 2-3/8" posi­tion. If required, press small black button on underside of bolt and pull to extend to 2-3/4" backset position.
Image (Fig. 3B) shows proper orientation when installing the bolt.
C. The outside escutcheon (with gasket) remains assembled.
Figure 3A
Detail 3B1
Figure 3B
An ASSA ABLOY Group brand
Outside Escutcheon
6
P/N AYRD220-INST-FUL Rev B
Loading...
+ 14 hidden pages