The Sorensen XPD Series features the smallest
500-watt programmable power supply available.
The XPD Series is ideal for benchtop, ATE and
OEM applications where a wide range of output
voltage or current is needed in a compact unit.
The XPD can be combined in a mix-and-match
conguration with the quarter-rack 300-watt
HPD series and 60-watt XT series. Each unit
features zero voltage “soft switching” to virtually
eliminate switching transients. This switching
technology contributes to high efciency, low
noise, and high reliability. The XPD series also
features power factor correction (PFC) technology
to enable low current draw and to greatly reduce
generation of input current harmonics.
7.5–120 V
4.5–67 A
115230
858.458.0223
sales.ppd@ametek.com
AMETEK
Programmable Power
9250 Brown Deer Road
San Diego, CA 92121-2267
USA
10252013
113
XPD Series : Product Specications
1
Output : Voltage and Current
Models7.5-6718-3033-1660-9120-4.5
Output Ratings
Output Voltage
Output Current
2
3
Output Power502.5 W540 W528 W540 W540 W
Line Regulation
4
Voltage2.8 mV3.8 mV5.3 mV8 mV14 mV
Current7.7 mA4 mA2.6 mA2 mA2 mA
Load Regulation
5
Voltage2.8 mV3.8 mV5.3 mV8 mV14 mV
Current11.7 mA8 mA6.6 mA5.9 mA5.5 mA
Meter Accuracy
Voltage (1% of Vmax + 1 count)0.2 V0.3 V0.5 V0.7 V2.2 V
Current (1% of Imax + 1 count)0.8 A0.4 A0.3 A0.2 A0.2 A
Output Noise (90-20 MHz)
Voltage (p-p)50 mV50 mV75 mV125 mV180 mV
Output Ripple
Voltage5 mV5 mV7.5 mV10 mV20 mV
6
Current
Drift (60 minutes)
7
Voltage (0.15% of Vmax)11.3 mV27 mV49.5 mV90 mV180 mV
Current (0.3% of Imax)201 mA90 mA48 mA27 mA13.5 mA
Drift (8 hours)
8
Voltage (0.03% of Vmax)2.3 mV5.4 mV9.9 mV18 mV36 mV
Current (0.05% of Imax)34 mA15 mA8 mA4.5 mA2.3 mA
Temperature Coefcient
9
Voltage (0.015% of Vmax/°C)1.2 mV2.7 mV5 mV9 mV18 mV
Current (0.02% of Imax/°C)13.4 mA6 mA3.2 mA1.8 mA0.9 mA
OVP Adjustment Range
(5% to 110% of Vmax)0.4-8.3 V0.9-19.8 V1.7-36.3 V3-66 V6-132 V
10
Efciency
0-7.5 V0-18 V0-33 V0-60 V0-120 V
0-67 A0-30 A0-16 A0-9 A0-4.5 A
250 mA250 mA150 mA150 mA75 mA
81% 83% 85% 85%84%
114
Specications subject to change without notice.
1. All electrical specications are represented at the full operating temperature range for all models, unless otherwise stated.
2. Minimum output voltage is < 0.15% of rated voltage at zero output setting.
3. Minimum output current is < 0.2% of rated current at zero setting when measured with rated load resistance. Front output current limited to 30 A maximum.
4. For input voltage variation over the AC input voltage range, with constant rated load.
5. For 0-100% load variation, with constant nominal line voltage.
6. Current mode noise is measured from 10% to 100% of rated output voltage, full current.
7. Maximum drift over 60 minutes with constant line, load, and temperature, after power up.
8. Maximum drift over 8 hours with constant line, load, and temperature, after 60 minute warm-up.
9. Change in output per °C change in ambient temperature, with constant line and load.
10. Typical efciency at 120 V and full output power.
11. Interface specications at 25°C ± 5°C, nominal line input of 120 Vac. Apply accuracy specications according to the following voltage program accuracy
example: Set a model 18-30 power supply to 10 V. The expected result will be within the range of 10 V ± 75 mV ± 0.12% of the set voltage of 10 V.
www.ProgrammablePower.com
XPD Series : Product Specications
1
500–540 W
XPD 500 W Internal Interface Specications with RS-232 or GPIB Interface Installed
Time Delay3 sec maximum, from power on to output stable
Voltage Mode Transient Response Time1 ms for output voltage to recover within 0.5% of its previous level after a step change in load current of up to 50% of rated output
Maximum Voltage Differential±300 Vdc from output to safety ground
Remote On/Off and Interlock5-15 V signal or TTL-compatible input, selectable logic. TTL input impedance: 2 k (in series with one diode drop)
Remote Analog Programming
(Full Scale Input)
Remote Programming &
Monitoring Accuracy
Front Panel Voltage and Current Control10-turn voltage and current potentiometers
Front Panel Voltage Control Resolution0.02% of maximum voltage
AC Input Connector TypeIEC 320 connector, appropriate power cord provided for destination country
Main Output ConnectorFront panel: ve-way binding posts. Maximum current limit 30 A; Rear Panel: 7.5-18 V models: Bus bars;
ApprovalsCE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certied to UL3111-1 and CSA C22.2 No 1010.1;
Voltage and current programming inputs (source must be oating): 0-10 V voltage sources. Input impedance (V and I): 20 k
1% of full scale output for the default range
33-120 V models: wire clamp connectors.
Meets USA EMC standard: FCC, part 15B, Class A; Meets Canadian EMC standard: ICES-001, Class A.