Features and specifications are subject to change at any time
without notice. Visit wolfappliance.com/specs for the most
up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient use of Wolf equipment,
T
please take note of the following types of highlighted
information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION signals a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
Wolf Pro Island Ventilation Hoods3
wolfappliance.com/specs
Pro Island Hood Installation
IMPORTANT NOTE: T
his installation must be completed
by a qualified installer or Wolf authorized service center
technician.
Read this entire installation guide prior to installation and
save for the local inspector’s reference. The homeowner
should keep this installation guide for future reference.
This appliance must be installed in accordance with
National Electrical Codes, as well as all state, municipal
and local codes. The correct voltage, frequency and
amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly
sized circuit breaker or time delay fuse. The proper
voltage, frequency, and amperage ratings are listed on the
product rating plate.
Record the model and serial numbers before installing the
ventilation hood. Both numbers are listed on the product
rating plate, located inside the left wall of the hood shell.
Refer to the illustration below.
olf Pro Island Hood
W
Model Number
Serial Number
RATING PLATE
Location of rating plate
(inside hood).
Safety Instructions4
IMPORTANT INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY, OBSERVE THE FOLLOWING:
•
Installation work and electrical wiring must be
done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated
construction.
•
Two installers are recommended due to the size and
weight of the pro ventilation hood.
•
Install the pro ventilation hood only with a blower
manufactured by Wolf.
•
When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
•
Ducted fans must always be vented to the outdoors.
TO REDUCE RISK OF RANGE TOP GREASE FIRE:
A) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on
low or medium settings.
B) Always turn the ventilation hood on when
cooking at high heat or when flambeing foods
such as crepes suzette or cherries jubilee.
C) Clean ventilation fans frequently. Grease should
not be allowed to accumulate on fan or filter.
D) Use proper pan size. Always use cookware
appropriate for the size of the surface burner.
To reduce the risk of fire and properly exhaust air,
be certain to duct air outside. Do not vent exhaust
air into spaces within walls or ceilings or into attics,
crawl spaces or garages.
The hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The motor will restart when it has cooled
down. If the motor continues to shut off and restart,
have the hood serviced.
TO REDUCE THE RISK OF INJURY TO PERSONS IN
THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
•
Smother flames with close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. Be careful to
prevent burns. If the flames do not go out immediately, evacuate and call the fire department.
•
Never pick up a flaming pan—you may be burned.
•
Do not use water, including wet dishcloths or towels
—a violent steam explosion will result.
USE AN EXTINGUISHER ONLY IF:
•
You know you have a class ABC extinguisher and
you already know how to operate it.
•
The fire is small and contained in the area where it
started.
•
The fire department is being called.
•
You can fight the fire with your back to an exit
(NFPA fire safety tips).
Installation Considerations5
wolfappliance.com/specs
Installation Considerations
Wolf pro ventilation hoods are recommended for use with
all Wolf cooking appliances. Island hoods should be larger
than the cooking surface by 3" (76) on each side. The
ventilation hood should be installed 30" (762) to 36" (914)
above the countertop.
• Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Wolf warranty. Refer to the Wolf pro
ventilation hoods use & care guide for warranty details,
or visit the contact & support section of our website,
wolfappliance.com.
• Make sure you have the tools and materials necessary
for proper installation.
• Warranty service must be performed by a Wolf author-
ized service center. Wolf is not responsible for service
required to correct a faulty installation.
MATERIALS INCLUDED WITH HOOD:
• Transition with backdraft damper—attached inside
hood (needs to be removed)
• Two control knobs
• Filters and grease cups (installed in hood)
BLOWER ASSEMBLIES
olf pro ventilation hoods are shipped without the blower
W
assembly. Internal, in-line and remote blowers are available through your authorized Wolf dealer. For local dealer
information, visit the find a showroom section of our
website, wolfappliance.com.
The blower will vary in size and is dictated by the cooking
surface, the volume of air that needs to be moved and the
length of the duct run. Refer to ventilation recommendations in the Wolf design guide.
IMPORTANT NOTE: Use only a Wolf blower with the pro
ventilation hood.
DUCT COVER
Optional stainless steel duct covers are available in a
variety of heights for all pro ventilation hoods through
your authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com.
IMPORTANT NOTE: Installing a duct cover will impact all
aspects of the hood installation including hood location,
ducting, electrical placement and the mounting surface.
• Installation package and hardware
• Installation guide, use & care guide and product
registration card
• Wolf logo nameplate
When performing installation, servicing or cleaning the
ventilation hood, it is recommended that safety glasses
and gloves be worn.
Pro Island Hood Specifications6
18" (457)
O
VERALL
HEIGHT
4
"
(102)
3
4"
(864)
OVERALL DEPTH
1
3"
(330)
WIDTH MINUS
18"
(457)
36" (914), 42" (1067), 54"(1372)
AND 6
6"
(1676) WIDTHS
LOCATION OF ELECTRICAL
THROUGH TOP OF HOOD
WIDTH OF HOOD
30" (762) TO
36" (914)
TO COUNTERTOP
18" (457)
HEIGHT
OF HOOD
34" (864)
DEPTH OF HOOD
Overall Dimensions
PRO ISLAND HOODS
Installation Specifications
PRO ISLAND HOODS
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.