Wolf EC24S Installation manual

Coffee Systems Installation Guide
COFFEE SYSTEMS
Contents
3 Coffee Systems
4 Specications
8 Troubleshooting
Features and specications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.
Important Note
To ensure this product is installed and operated as safely and efciently as possible, take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
2 | Wolf Customer Care 800.222.7820
2 | Wolf Customer Care 800.222.7820
COFFEE SYSTEMS
Product Information
Important product information including the model and serial number are listed on the product rating plate. The unit must be slid forward to view the rating plate. Refer to the illustration below.
If service is necessary, contact Wolf factory certied service with the model and serial number. For the name of the nearest Wolf factory certied service or for questions regarding the installation, visit the contact & support section of our website, wolfappliance.com or call Wolf customer care at 800-222-7820.
RATING PLATE
IMPORTANT INSTRUCTIONS
CAUTION
Installation must be performed by a qualied
professional in compliance with legislation in force in the country of installation (see section “Built-in installation”).
The packing elements (plastic bags, polystyrene
foam, etc.) should be kept out of reach of children.
Never install the appliance in rooms where the tem-
perature may drop to 32°F
Customize the water hardness as soon as possible
following the instructions in the use & care guide.
WARNING
Check that the main power supply voltage
corresponds to the value indicated on the rating plate on the side of the appliance.
Connect the appliance to an efciently earthed and
correctly installed socket with a minimum current rating of 15 amps only.
(0°C) or lower.
Rating plate location.
If the power socket does not match the plug on the
appliance, have the socket replaced with a suitable type by a qualied professional.
To comply with safety directives, an omnipolar
switch with a minimum contact distance of must be installed.
Do not use multiple sockets or extensions.
1
/8" (3)
CAUTION
Safety cutout devices must be included in the main power supply in compliance with the installation regula­tions in the country concerned.
wolfappliance.com | 3
SPECIFICATIONS
Installation Requirements
The coffee system can be installed in a standard or ush inset application. The sides of the cabinetry opening must be adequate to support installation of the mounting slides.
Finish the edges of the opening. They may be visible when the door is open.
For standard installations, face trim will overlap stiles and rails. Refer to the chart below.
1
For ush inset installations, a minimum required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
The Wolf coffee system is designed and agency approved for installation with Wolf built-in ovens, microwaves and warming drawers only.
If a coffee system is installed above a cup warming drawer, one opening for both units must be specied.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Coffee System 100 lb (45 kg)
TRIM OVERLAP
Top Bottom 0" (0) Sides
/8" (3) reveal is
3
11
/16" (18)
/16" (5)
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz Service 15 amp dedicated circuit Receptacle 3-prong grounding-type Power Cord 6'
RATING PLATE
(1.8 m)
4 | Wolf Customer Care 800.222.7820
Rating plate location.
SPECIFICATIONS
SIDE
NOTE: Dashed line represents profile of unit.
Coffee System
STANDARD INSTALLATION
SLIDE
SUPPORT
OPENING
TOP VIEW
219/16"
(548)
DEPTH
SLIDE
SUPPORT
VIEW
1711/16" (449)
OPENING
HEIGHT
E
(562)
221/8"
OPENING WIDTH
FRONT VIEW
wolfappliance.com | 5
SPECIFICATIONS
SIDE
*W
Dashed line represents profile of unit
Coffee System
FLUSH INSET INSTALLATION
SLIDE
SUPPORT
181/8" (460)
FLUSH INSET
HEIGHT
SLIDE
SUPPORT
23" (584)
FLUSH
TOP VIEW
5
/16"(8)
E
1
(3)
/8"
INSET
DEPTH
7
/8" (22)
13
/16"
(21)
233/4" (603)
FLUSH INSET WIDTH
FINISHED
CLEATS*
VIEW
ill be visible and should be finished to match cabinetry.
6 | Wolf Customer Care 800.222.7820
FRONT VIEW
.
INSTALLATION
Installation
1 Ensure the sides of the cabinetry opening are adequate
to support installation of the slides. If necessary, install additional side cleats maintaining the opening width.
2 Position slides on the sides of the cabinet opening as
shown in the illustration below. Spacer material provided, can be added under or at the sides of the cabinet to ensure a proper t. If the unit is to be installed over a warming drawer, use the top surface as a reference to position slides (there will be no surface to rest the slides on).
3 Secure the slides with screws provided. Extend slides
forward to full extension.
14"
(356)
3
(19)
/4"
TYPICAL
10"
(254)
4 Position the unit on the slides. Verify the pins are inserted
into the housings properly, then secure with screws pro­vided. If the height of the unit requires adjustment, use the spacer disks provided. Refer to the illustration below.
5 Secure the power cord clip provided to the top of the
cabinet opening, centered and approximately 14"
(356)
back from the front edge. Position the power cord through it and plug into the electrical outlet on the back wall of the opening. The power cord must be long enough to allow the unit to be slid forward.
POWER
CORD CLIP
C
L
SPACER DISK
Slide support.
Install slides.
Install unit on slides.
Install power cord clip.
wolfappliance.com | 7
wolfappliance.com | 7
INSTALLATION
Installation
COMPLETE THE INSTALLATION
1 Fill the water tank.
2 Slide unit forward and press the main power switch
located behind the front (right) control panel.
3 Select desired language. To select, scroll through
languages until desired language is displayed, then press and hold
4 Press . Hot water will be dispensed from the hot
water spout.
5 The unit will turn off automatically after initial power up is
complete.
.
Troubleshooting
IMPORTANT NOTE: If the coffee system does not operate
properly, follow these troubleshooting steps:
Verify electrical power is supplied to the unit.
Verify proper electrical connections.
If the coffee system does not operate properly, con-
tact Wolf factory certied service. Do not attempt to repair the appliance. Wolf is not responsible for service required to correct a faulty installation.
8 | Wolf Customer Care 800.222.7820