To make sure this product is installed and operated safely
and efficiently, take note of the following types of
highlighted information throughout this guide:
IMPORTANT NOTE: Highlights information that is
especially important.
CAUTION
Indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING
States a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specified.
2 | English
RATING
PLATE
E Series Oven
Product Information
Product Information
Important product information, including the model and
serial number, are listed on the product rating plate. If
service is necessary, contact Wolf Factory Certified
Service with the model number and serial number. For
the name of the nearest Wolf Factory Certified Service or
for questions regarding the installation, visit the Product
Support section of our website, or call Wolf Customer
Care at 800-222-7820.
The rating plate is located near the bottom trim on the
left. The oven door must be open to view the rating plate.
wolfappliance.com | 3
Specifications
Installation Requirements
Installation Requirements
The oven can be installed in a standard or flush inset
application. If a cooktop is installed above an oven, a
minimum of 1/4" (6) is required between the units. The
location of the electrical supply within the oven opening
may require additional cabinet depth.
Bas e S u p portMin
Single Oven250 lb (115 kg)
Double Oven400 lb (181 kg)
Finish the edges of the opening. They may be visible
when the door is open.
For standard installations, the face trim overlaps stiles and
rails.
Tri m O v e rlapDim e n s i o n
Top1" (25)
Bottom0"
Sides
11
/16" (18)
Dual Installation
Two 30" single ovens can be installed side by side in a
standard or flush inset application. A dual installation kit is
required. To maintain appropriate airflow, the ovens must
be installed into one opening. Any cosmetic or structural
material placed between the ovens will impede airflow
and is not recommended. Refer to the illustrations on the
following pages.
The dual installation kit is available through an authorized
Wolf dealer. For local dealer information, visit the locator
section of our website subzero-wolf.com.
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
4 | English
Specifications
Electrical Requirements
Electrical Requirements
Installation must comply with all applicable electrical
codes.
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on pages
6-11. For ease of installation, the electrical supply for the
oven can be placed in an adjacent cabinet within reach of
the conduit.
Performance may be compromised if the electrical supply
is less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground
conductor. The wiring diagram covering the control
circuit is provided with the oven.
ELE C T R I C AL REQUIR E M E N T S-Single O v e n
Electrical Supply
Service30 amp dedicated circuit
Conduit4' (1.2 m)
Total Amps22
Max Connected Load5.4 kW
ELE C T R I C AL REQUIR E M E N T S-Double O v e n
Electrical Supply
Service50 amp dedicated circuit
Conduit5' (1.5 m)
Total Amps45
Max Connected Load10.8 kW
grounded, 240/208 VAC,
60Hz
grounded, 240/208 VAC,
60Hz
wolfappliance.com | 5
281/2" (724)
OPENING WIDTH
E
5"
(127)
E
E
4"
(102)
FRONT VIEWSIDE VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
231/4" (591)
OPENING
DEPTH
TOP VIEW
271/2"
(699)
OPENING
HEIGHT
Specifications
30" Single Oven Standard
30" Single Oven Standard
Installation
Installation
6 | English
301/8" (765)
FLUSH INSET WIDTH**
*Shaded areas will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
283/4"
(730)
FLUSH INSET
HEIGHT**
E
5"
(127)
4"
(102)
FRONT VIEWSIDE VIEW
11/8" (29)
1
/8" (3)
13
/16" (21)
24" (610)
FLUSH INSET
DEPTH
7
/8" (22)
TOP VIEW
E
E
FINISHED
CLEATS*
Specifications
30" Single Oven Flush Inset
30" Single Oven Flush Inset
Installation
Installation
wolfappliance.com | 7
281/2" (724)
OPENING WIDTH
E
5"
(127)
4"
(102)
E
E
FRONT VIEWSIDE VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
497/8"
(1267)
OPENING
HEIGHT
231/4" (591)
OPENING
DEPTH
17" (432)
TYPICAL
TOP VIEW
Specifications
30" Double Oven Standard
30" Double Oven Standard
Installation
Installation
8 | English
301/8" (765)
FLUSH INSET WIDTH**
E
5"
(127)
4"
(102)
FRONT VIEWSIDE VIEW
511/8"
(1299)
FLUSH INSET
HEIGHT**
11/8" (29)
1
/8" (3)
13
/16" (21)
24" (610)
FLUSH INSET
DEPTH
17" (432)
TYPICAL
TOP VIEW
E
E
FINISHED
CLEATS*
*Shaded areas will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
7
/8" (22)
Specifications
30" Double Oven Flush
30" Double Oven Flush
Inset Installation
Inset Installation
wolfappliance.com | 9
E
5"
(127)
EE
4"
(102)
E
5"
(127)
4"
(102)
FRONT VIEWSIDE VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
231/4" (591)
OPENING
DEPTH
TOP VIEW
271/2"
(699)
OPENING
HEIGHT
581/2" (1486)
OPENING WIDTH
Specifications
30" Single Oven Dual
30" Single Oven Dual
Standard Installation
Standard Installation
10 | English
E
5"
(127)
4"
(102)
E
5"
(127)
4"
(102)
FRONT VIEWSIDE VIEW
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
**Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
283/4"
(730)
FLUSH INSET
HEIGHT**
11/8" (29)
1
/8" (3)
13
/16" (21)
24" (610)
FLUSH INSET
DEPTH
7
/8" (22)
601/8" (1527)
FLUSH INSET WIDTH**
TOP VIEW
EE
FINISHED
CLEATS*
Specifications
30" Single Oven Dual Flush
30" Single Oven Dual Flush
Inset Installation
Inset Installation
wolfappliance.com | 11
HINGE
LOCK
SCREW
Installation
Preparation
Preparation
Electrical Connection
Before moving the oven, protect any finished flooring and
secure the oven door(s) closed to prevent damage.
Use an appliance dolly to move the oven near the
opening. Place the appliance dolly on the side or back to
prevent damage. Remove and recycle packing materials.
Do not lift or carry the oven by the door handle.
Oven Door Removal
To lighten the load, the oven door(s) can be removed.
Remove only if necessary. Door removal should be done
only by a certified installer or service technician. Do not
lift or carry the oven door by the door handle.
To remove, open the door completely. Rotate both hinge
locks back completely, remove the screw closest to the
hinge on both sides of the door, and pull the door
forward.
To install, slide the door onto the hinges. Rotate the hinge
locks forward completely and install the screws.
WARNING
Verify that power is disconnected from the electrical
box before proceeding.
If the electrical supply is located in the opening, electrical
connection must be made prior to placing the oven in the
opening. If the electrical supply is in an adjacent cabinet,
electrical connection can be made after placing the oven
in the opening. The conduit on the back of the unit allows
for a 3-wire or 4-wire installation.
1
Connect the black appliance wire to the black (L1)
power supply.
2
Connect the red appliance wire to the red (L2) power
supply.
3
Connect the bare appliance wire to the green/ground
wire.
4
For a four-wire system, install a wire nut on the white/
neurtral wire.
Installation
Place the oven in the opening and slide into position. To
ensure adequate depth for proper installation, the conduit
must fit into the recessed area along the rear edge of the
oven.
Locate the mounting hole in each side trim. Drill 1/16" (2)
pilot holes and install #6 x 3/4" screws.
Remove and recycle packing materials including the
white protective material behind each rack guide
mounting location.
12 | English
Loading...
+ 26 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.