Wolf 822171, 822170, 822167, 822169, 822166 Installation

...
Contents
WIDTH OF HOOD
GRAY LINES INDICATE VERTICAL AND HORIZONTAL WALL FRAMING
26
1
/4
" (667)
MOUNTING CUT-OUT CENTER
13" (330)
WALL
CUT-OUT
10
3
/4
"
(273)
C
L
17
1
/2
"
(446)
15
1
/16
"
(383)
Pro Wall Hood Horizontal Discharge Installation
wolfappliance.com 800.222.7820
HORIZONTAL DISCHARGE
1 Panel, back
2 Bracket, mounting
3
4 Screw, #8 x
/8"
1
/2"
12 Washer, at #12
1 Instructions
Pro 24" and 27" Deep Wall Hoods
WALL PREPARATION
Minimum 2" (51) x 4" (102) lumber is required to construct wall framing. Additional horizontal framing may be required for sufcient anchoring and support.
HOOD PREPARATION
1 Hood is shipped with back panel in place. Damper is
attached upside down to inside top surface of back panel. Refer to the illustration below.
2 To remove lters, press upward then rotate bottom
outward. To aide in removal, remove center lter rst. Remove grease cups from bottom edge of hood. Gloves should be worn when handling lters.
3 Detach existing back panel and damper assembly from
hood by removing the top and back screws. Do not discard screws.
4 Turn assembly over and place on a protected work
surface. Separate damper from back panel by removing the hold-down brackets. Do not discard brackets and screws. Refer to the illustration below.
DAMPER
BACK PANEL
Hood Installation.
HOLD-DOWN
BRACKET
Damper inside hood.
Remove damper.
PACKAGING
MATERIAL
page 1 of 2
Pro 24" and 27" Deep Wall Hoods
wolfappliance.com 800.222.7820
IMPORTANT NOTE: Remove packaging material used to
prevent ap damage during shipping. Damper will not function properly unless this material is removed prior to mounting the hood.
5 Separate electrical box from back panel by removing
two nuts, then reinstall on new back panel. Refer to the illustration below.
6 For internal blowers, mount blower to mounting studs
on the new back panel using nuts supplied with blower.
7 Turn back panel assembly upright and reattach using
screws previously removed.
8 Mount damper and two hold-down brackets to the
back of the hood. Verify the damper is hinged vertically. Damper drops into place and damper tongues drop into slots on the back panel. Hold-down brackets clamp on the damper groove overhang. Secure hold-down brackets using two screws per bracket. Refer to the illus­tration below. Seal with aluminum tape or high tempera­ture duct tape to ensure a tight seal.
HOOD INSTALLATION
1 Attach the two mounting brackets to wall framing using
2 Align cut-outs on the back of the hood with the mounting
#10 x 1
1
/2" (38) screws and washers provided.
brackets. If additional support is required, drill supple­mentary mounting holes in the back panel and use these holes to attach the hood assembly to wall framing.
3 Connect damper to duct using sheet metal screws and
aluminum tape or high temperature duct tape. Verify screws do not affect operation of the damper.
ELECTRICAL
MOUNTING
STUD
ACCESSORY BACK PANEL
Mounting stud location.
BOX
DAMPER
Mount damper.
822172 REV-A 12/2012
page 2 of 2