Electronic
pressure measurement
Electronic pressure switch with display
Model PSD-30, standard version
Model PSD-31, with flush diaphragm
WIKA data sheet PE 81.67
Applications
■■ Machine tools
■■ Hydraulics and pneumatics ■■ Pumps and compressors ■■ Machine building
Special features
nAvailable with single or dual NPN or PNP solid state switches
nHigh visibility, rugged 14-segment red LED display electronically rotates 180° for top-down installation
nIndependent rotation between the M12x1 electrical
connection and the display |
Electronic pressure switch, model PSD-30 |
n User-friendly, intuitive 3-key operation |
nVersions with 4-20 mA or 0-10V analog output available
nProgramming menu meets VDMA Standards for user friendly navigation
Description
Award-winning in design and functionality
The successful design and the excellent functionality of the
WIKA switch family were already confirmed by winning the
“iF product design award 2009” for the PSD-30 pressure switch.
The robust 14 segment LED display has been designed using 0.35in (9 mm) high characters and with a slight incline in order to make reading the pressure as easy as possible from a distance.
The 3-key operation makes simple, intuitive menu navigation possible, with no need for additional assistance. The menu navigation conforms to the latest VDMA standard.
TheVDMA standard for fluid sensors (24574-1, part 1 - pressure switches) has the aim of simplifying the use of pressure switches by standardising menu navigation and display.
The control keys have been designed as large as possible and are arranged ergonomically to ensure fast and easy adjustments. Operation without any additional assistance is made easier through the tactile feedback.
WIKA data sheet PE 81.67 ∙ 02/2016
Customised installation
The installation of the model PSD-30 and PSD-31 can be flexibly adapted to the individual mounting situation.Due to the almost unlimited rotation of the display and case by more than 300°, the display can be adjusted independently of the electrical connection. The display can thus always be aligned to face the operator, and the M12 x 1 connection positioned to suit the desired cable routing.
High quality
During development of the WIKA switch family a high value was placed on a robust design and the selection of appropriate materials suited for machine-building applications. For this reason the case and the threaded connection of the electrical connector are made from stainless steel. Overwinding or tearing off the connector is therefore virtually impossible.
IO-Link
With the optional output signal in accordance with the IO-Link communication standard, the PSD-30 and PSD-31 allow a fast integration into modern automation systems. IO-Link offers an even faster installation, parameterisation and higher functionality of the model PSD-30 and PSD-31.
Page 1 of 8
Data sheets showing similar products:
Electronic temperature switch with display;modelTSD-30;see data sheetTE 67.03
Electronic level switch with display; model LSD-30; see data sheet LM 40.01
Measuring ranges
Gauge pressure
bar |
0 ... |
1 1) |
0 ... |
1.6 1) |
0 ... |
2.5 |
0 ... |
4 |
0 ... |
6 |
0 ... |
10 |
0 ... |
16 |
0 ... |
25 |
psi |
0 ... |
40 |
0 ... |
60 |
0 ... |
100 |
0 ... |
160 |
0 ... |
250 |
0 ... |
400 |
0 ... |
600 |
|
|
0 ... |
15 1) |
0 ... |
25 1) |
0 ... |
30 1) |
0 ... |
50 |
0 ... |
100 |
0 ... |
160 |
0 ... |
200 |
0 ... |
300 |
|
|
0 ... |
500 |
0 ... |
1,000 |
0 ... |
1,500 |
0 ... |
2,000 |
0 ... |
3,000 |
0 ... |
5,000 |
0 ... |
8,000 |
|
|
Absolute pressure
bar |
0 ... |
1 1) |
0 ... |
1.6 1) |
0 ... |
2.5 |
0 ... |
4 |
0 ... |
6 |
0 ... |
10 |
0 ... |
16 |
0 ... |
25 |
psi |
0 ... |
15 1) |
0 ... |
25 1) |
0 ... |
30 1) |
0 ... |
50 |
0 ... |
100 |
0 ... |
160 |
0 ... |
200 |
0 ... |
300 |
Vacuum and +/- measuring range
bar |
-1 ... 0 1) |
-1 ... +0.6 1) |
-1 ... +1.5 |
-1 ... +3 |
-1 ... +5 |
-1 ... +9 |
-1 ... +15 |
-1 ... +24 |
psi |
-14.5 ... 0 1) |
-14.5 ... +15 1) |
-14.5 ... +30 |
-14.5 ... +50 |
-14.5 ... +100 |
-14.5 ... +160 |
-14.5 ... +200 |
-14.5 ... +300 |
1) Not available for PSD-31.
Overpressure limit
2 times
1.7 times for the relative pressure measuring ranges 160 psi,
1,000 psi and 1,500 psi
Display
14-segment LED, red, 4-digit, 9 mm (0.35 inch) character size Display can be turned electronically through 180°
Update (adjustable): 100, 200, 500 or 1,000 ms
Output signals
Switching output |
SP2 |
Analogue signal |
SP1 |
|
|
PNP |
- |
4 ... 20 mA (3-wire) |
PNP |
- |
DC 0 ... 10 V (3-wire) |
PNP |
PNP |
- |
PNP |
PNP |
4 ... 20 mA (3-wire) |
PNP |
PNP |
DC 0 ... 10 V (3-wire) |
Optionally also available with an NPN instead of a PNP switching output
IO-Link, revision 1.1 (option)
IO-Link is optionally available for all output signals.
With the IO-Link option, switching output SP1 is always PNP
Zero offset adjustment max. 3 % of span
Switching thresholds
Switch point 1 and switch point 2 are individually adjustable
Switching functions
Normally open, normally closed, window, hysteresis Freely adjustable
Switching voltage
Power supply - 1 V
Switching current
■■ without IO-Link: max. 250 mA
■■ with IO-Link: |
SP1 max. 100 mA |
|
SP2 max. 250 mA |
Settling time |
|
Analog signal: |
3 ms |
Switching output: ≤ 10 ms (20 ms with IO-Link)
Load |
|
Analog signal 4 ... 20 mA: |
≤ 0.5 kΩ |
Analog signal DC 0 ... 10 V: |
> 10 kΩ |
Service life |
|
100 million switching cycles |
|
Page 2 of 8 |
WIKA data sheet PE 81.67 ∙ 02/2016 |
Voltage supply
Power supply
DC 15 ... 35 V
Current consumption
Switching outputs with
■■ Analog signal 4 ... 20 mA: |
70 mA |
■■ Analog signal DC 0 ... 10 V: |
45 mA |
■■ without analog signal: |
45 mA |
IO-Link option causes a deviating current consumption
Total current consumption
■■ without IO-Link: max. 600 mA including switching current ■■ with IO-Link: max. 450 mA including switching current
Accuracy specifications
Accuracy, analog signal
≤ ±1.0 % of span
Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). Calibrated in vertical mounting position with process connection facing downwards.
Non-linearity: ≤ ±0.5 % of span (BFSL, IEC 61298-2) Long-term drift: ≤ ±0.2 % of span (IEC 61298-2)
Accuracy, switching output
Switch point accuracy: ≤ ±1 % of span Adjustment accuracy: ≤ ±0.5 % of span
Display
≤ ±1.0 % of span ± 1 digit
Temperature error in rated temperature range
■■ typical: ≤ ±1.0 % of span ■■ maximum: ≤ ±2.5 % of span
Temperature coefficients in rated temperature range
Mean TC zero point: ≤ ± 0.2 % of span/10 K (typical) Mean TC span: ≤ ± 0.1 % of span/10 K (typical)
Operating conditions
Permissible temperature ranges
Medium: -4 ... +185 °F (-20 ... +85 °C) Ambient: -4 ...+176 °F (-20 ...+80 °C) Storage: -4 ...+176 °F (-20 ...+80 °C)
Nominal temperature: 32 ...176 °F (0 ...80 °C)
Humidity
45 ...75 % r.h.
Vibration resistance
10 g (IEC 60068-2-6, under resonance)
Shock resistance
50 g (IEC 60068-2-27, mechanical)
Service life, mechanics
100 million load cycles (10 million load cycles for measuring ranges > 600 bar/7,500 psi)
Ingress protection
IP 65 and IP 67
The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the appropriate ingress protection.
Mounting position as required
Reference conditions
Temperature: 59 ...77 °F (15 ...25 °C) Atmospheric pressure: 13.78 ...15.23 psi (950 ...1,050 mbar)
Humidity: |
45 ...75 % r.h. |
Nominal position: |
Process connection lower mount (LM) |
Power supply: |
DC 24 V |
Load: |
see output signals |
WIKA data sheet PE 81.67 ∙ 02/2016 |
Page 3 of 8 |