WIKA OLS-C20 User Manual [en, de, es, fr]

Operating instructions Betriebsanleitung Mode d'emploi Manual de instrucciones
Kleingrenzschalter, Typ LSO.02
Contacteur de niveau limite, type LSO.02
Interruptor de nivel, modelo LSO.02
GB
D
F
E
Mini limit switch, model LSO.02
Operating instructions model LSO.02 Page 3 - 16
GB
D
Betriebsanleitung Typ LSO.02 Seite 17 - 30
Mode d'emploi type LSO.02 Page 31 - 44
F
Manual de instrucciones modelo LSO.02 Página 45 - 57
E
© WIKA Alexander Wiegand SE & Co. KG 2010
Prior to starting any work, read the operating instructions! Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen! Zum späteren Gebrauch aufbewahren!
Lire le mode d'emploi avant de commencer toute opération ! A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo! ¡Guardar el manual para una eventual consulta posterior!
2
WIKA operating instructions mini limit switch, model LSO.02
13334591.02 10/2010 GB/D/F/E
Contents
Contents
1. General information 4
2. Safety 5
3. Specications 8
4. Design and function 9
5. Transport, packaging and storage 10
6. Commissioning, operation 11
7. Maintenance and cleaning 12
8. Faults 13
9. Warranty 14
GB
10. Dismounting, return and disposal 14
13334591.02 10/2010 GB/D/F/E
WIKA operating instructions mini limit switch, model LSO.02 3
1. General information
1. General information
GB
The mini limit switch described in the operating instructions has been manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria during production. Our management systems are certied to ISO 9001 and ISO 14001.
These operating instructions contain important information on handling the mini limit switch. Working safely requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the mini limit switch's range of use.
The operating instructions are part of the instrument and must be kept in the immediate vicinity of the mini limit switch and readily accessible to skilled personnel at any time.
Skilled personnel must have carefully read and understood the operating instructions, prior to beginning any work.
The manufacturer's liability is void in the case of any damage caused by using the product contrary to its intended use, non-compliance with these operating instructions, assignment of insuciently qualied skilled personnel or unauthorised modications to the mini limit switch.
The general terms and conditions contained in the sales documentation, shall apply.
Subject to technical modications.
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: LM 31.01
- Application concultant: Tel.: (+49) 9372/132-0 Fax: (+49) 9372/132-406 E-Mail: info@wika.de
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation, which can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation, which can result in light injuries or damage to equipment or the environment, if not avoided.
4 WIKA operating instructions mini limit switch, model LSO.02
13334591.02 10/2010 GB/D/F/E
1. General information / 2. Safety
Information
... points out useful tips, recommendations and information for ecient and trouble-free operation.
DANGER!
...identies hazards caused by electric power. Should the safety instructions not be observed, there is a risk of serious or fatal injury.
WARNING!
... indicates a potentially dangerous situation that can result in burns, caused by hot surfaces or liquids, if not avoided.
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate instrument has been selected in terms of measuring range, design and specic measuring conditions. Non-observance can result in serious injury and/or damage to equipment.
GB
Further important safety instructions can be found in the individual chapters of these operating instructions.
2.1 Intended use
This instrument is designed to detect limit levels of liquids. The values given in chapter "3. Specications" must not be exceeded. The mini limit switch is not suitable for milky, turbid, outgassing, sticky and crystallising media.
The mini limit switch has been designed and built solely for the intended use described here, and may only be used accordingly.
The technical specications contained in these operating instructions must be observed. Improper handling or operation of the mini limit switch outside of its technical specications requires the instrument to be shut down immediately and inspected by an authorised WIKA service engineer.
13334591.02 10/2010 GB/D/F/E
WIKA operating instructions mini limit switch, model LSO.02 5
2. Safety
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
GB
2.2 Personnel qualication
WARNING! Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled personnel who have the qualications described below.
Keep unqualied personnel away from hazardous areas.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training, knowledge of measurement and control technology and on their experience and knowledge of country-specic regulations, current standards and directives, are capable of carrying out the work described and independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
2.3 Special hazards
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic gases or liquids, and refrigeration plants, compressors, etc., in addition to all stand­ard regulations, the appropriate existing codes or regulations must also be followed.
WARNING!
To ensure safe working on the instrument, the operating company must ensure
that suitable rst-aid equipment is available and aid is provided whenever required.
that the operating personnel are regularly instructed in all topics regarding work safety, rst aid and environmental protection and knows the operating instructions and, in particular, the safety instructions contained therein.
6 WIKA operating instructions mini limit switch, model LSO.02
13334591.02 10/2010 GB/D/F/E
2. Safety
DANGER!
Danger of death caused by electric current Upon contact with live parts, there is a direct danger of death.
Electrical instruments may only be installed and mounted by skilled electri­cal personnel.
Operation using a defective power supply unit (e.g. short circuit from the mains voltage to the output voltage) may result in life-threatening voltages
on the instrument!
WARNING!
Residual media in dismounted instruments may result in a risk to people, the environment and the system. Take sucient precautionary measures.
Do not use this instrument in safety or Emergency Stop devices. Incorrect use of the instrument can result in injury.
Should a failure occur, aggressive media with extremely high temperature and under high pressure or vacuum may be present at the instrument.
2.4 Labelling / safety marks
GB
Product label
Model
Electrical connection diagram
Explanation of symbols
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
13334591.02 10/2010 GB/D/F/E
WIKA operating instructions mini limit switch, model LSO.02 7
3. Specications
3. Specications
General Data
GB
Measuring accuracy ±0.5 mm Ambient light max. 10,000 Lux (immersed) Mounting position any Weight 0.15 kg
Design Data
Medium temperature -30 ... +140 °C Ambient temperature -25 ... +70 °C Working pressure 0 ... 5 MPa (0 ... 50 bar) Measuring length see drawing on page 9 Process connection G ½ A, M16 x 1.5, ½ NPT etc. see drawing on page 9
Materials
Sensor
Tip
Electronics housing
Stainless steel 1.4571 Quartz Stainless steel 1.4301
Electrical Data
Supply voltage DC 24 V -25 ... +30 % Supply current max. 40 mA Power consumption 1 W
Output
Voltage
Current
other
Switching current (Tu = 70 °C)
Electrical connection
Ingress protection
With plug
With cable
For further specications see WIKA data sheet LM 31.01 and order documentation.
8 WIKA operating instructions mini limit switch, model LSO.02
DC 24 V
0.5 A at Tu 70 °C short-circuit protection, reverse voltage protection, current, voltage and power limitation
0.5 A
PVC cable 3 x 0.14 mm²
Plug 4-pole series 713, M12
IP 65 per EN 60 529 IP 66 per EN 60 529
13334591.02 10/2010 GB/D/F/E
4. Design and function
4. Design and function
4.1 Description
Principle of operation
This instrument is designed to detect limit levels of liquids. For this purpose the sensor is equipped with a V-shaped glass-tip. The model is also ideally suited for level control, particularly in applications requiring high precision. The measurement principle is independent of the colour, refractive index, density, conductance and dielectric constant of the liquid.
Integrated electronics include limit sensing and self­calibration. The output is an open-collector pnp-transistor.
Gas Liquid
4.2 Instrument design
The sensor is a one-piece device consisting of a mechanical connection which depends on the type of sensor, and integrated electronics built into a stainless steel housing. The measuring length, ML, to the sealing face is always 24 mm.
Dimensions in mm
Model LSO.02 with cable connection
green LED
Plug connection
GB
cable
length
3000
Selectable process connections
Process connection
Ø A
Spanner width
B
Sealing face
Ø C
M16 x 1.5 SW24 Ø 21 G ½ A SW30 Ø 26 ½ NPT SW24 -
4.3 Scope of delivery
Cross-check scope of delivery with delivery note.
13334591.02 10/2010 GB/D/F/E
WIKA operating instructions mini limit switch, model LSO.02 9
5. Transport, packaging, storage
5. Transport, packaging and storage
5.1 Transport
GB
Check instrument for any damage that may have been caused by transport. Obvious damage must be reported immediately.
5.2 Packaging
Do not remove packaging until just before mounting. Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for repair).
5.3 Storage Permissible conditions at the place of storage:
Storage temperature: -25 ... +70 °C
Humidity: 35 ... 85 % relative humidity (no condensation)
Avoidance of exposure to the following factors:
Proximity to hot objects
Mechanical vibration, mechanical shock (putting it down hard)
Soot, vapour, dust and corrosive gases
Potentially explosive environments, ammable atmospheres
Store the instrument in its original packaging in a location that fullls the conditions listed above. If the original packaging is not available, package and store the instrument as described below:
1. Wrap the instrument in an antistatic plastic lm.
2. Place the instrument, along with shock-absorbent material, in the packaging.
3. If stored for a prolonged period of time (more than 30 days), place a bag, containing a desiccant, inside the packaging.
WARNING!
Before storing the instrument (following operation), remove any residual media. This is of particular importance if the medium is hazardous to health, e.g. caustic, toxic, carcinogenic, radioactive, etc.
10 WIKA operating instructions mini limit switch, model LSO.02
13334591.02 10/2010 GB/D/F/E
6. Commissioning, operation
6. Commissioning, operation
When unpacking the mini limit switch check all items for external damage. A functional test may be carried out prior to the installation. To do this, the device should be temporarily connected and the sensor-tip immersed in and then withdrawn from a glass of water.
WARNING!
The electrical connection must only be carried out by qualied skilled personnel. Observe the relevant VDE regulations.
6.1. Installation instructions
horizontal installation
tank or pipe wall
rubber or metal seal
welded adapter
vertical installation
ATTENTION! In the case of
electropolished pipes
min. distance can be
much larger than 10 mm.
GB
inclined installation
13334591.02 10/2010 GB/D/F/E
high-temperature medium
long adapter
Insulation
WIKA operating instructions mini limit switch, model LSO.02 11
6. Commissioning, operation / 7. Maintenance and cleaning
6.2 Mechanical installation of the Mini Limit Switch
Mount the mini limit switch, pressure tight, into the process connection. The distance between sensor-tip and opposite surface of the pipe should be greater than 10 mm. If the
GB
pipe is electropolished, the distance should be increased accordingly.
6.3. Electrical connection of the mini limit switch
The sensor must be connected as shown in the connection diagram.
Electrical connection diagram
brown
Connector assignment
green
O. C. pnp
white
Switching direction
The switching direction is factory set:
Output
Load
Output
Model Function Condition LED Output transistor Ext. relay
SE Normally
open
SE Normally
open
SA Normally
closed
SA Normally
closed
immersed on switch on connect
not immersed o switch o disconnect
immersed o switch o disconnect
not immersed on switch on connect
7. Maintenance and cleaning
7.1 Maintenance
As a rule, the Mini Limit Switch is maintenance-free. If the plant is subject to heavy contamination or scale, it is advisable to set up periodic maintenance. This depends on the optical condition of the glass tip and the switch operation.
Repairs must only be carried out by the manufacturer.
12 WIKA operating instructions mini limit switch, model LSO.02
13334591.02 10/2010 GB/D/F/E
7. Maintenance, cleaning / 8. Faults
7.2 Cleaning
CAUTION!
Before cleaning, correctly disconnect the instrument from the pressure supply, switch it o and disconnect it from the mains.
Clean the instrument with a moist cloth.
Electrical connections must not come into contact with moisture.
Wash or clean the dismounted instrument before returning it, in order to protect sta and the environment from exposure to residual media.
Residual media in dismounted instruments can result in a risk to persons, the environment and equipment. Take sucient precautionary measures.
For information on returning the instrument see chapter "10.2 Return".
8. Faults
Faults Possible causes Measures
No function No power supply Measure power supply, check
connection to cable or plug
No function in spite of liquid level change
Sensor works to reverse logic
Contamination or scale on the glass-tip
SA instead of SE or SE instead of SA specied
Clean glass-tip (set up periodic maintenance)
Change sensor
GB
CAUTION!
If faults cannot be eliminated by means of the measures listed above, the instrument must be shut down immediately, and it must be ensured that pressure and/or signal are no longer present, and it must be prevented from being inadvertently put back into service. In this case, contact the manufacturer. If a return is needed, please follow the instructions given in chapter "10.2 Return".
13334591.02 10/2010 GB/D/F/E
WIKA operating instructions mini limit switch, model LSO.02 13
9. Warranty / 10. Dismounting, return and disposal
9. Warranty
The warranty period is 24 months.
GB
Under the condition that this Mini Limit Switch has been handled and operated in accordance with these operating instructions. For consumable and spare parts the warranty is restricted to faults in material or construction.
10. Dismounting, return and disposal
WARNING!
Residual media in dismounted instruments can result in a risk to persons, the environment and equipment. Take sucient precautionary measures.
10.1 Dismounting
WARNING!
Risk of burns! Let the instrument cool down suciently before dismounting it! When dismounting it, there is a risk that dangerously hot pressure media may escape.
Only disconnect the mini limit switch once the system has been depressurised!
10.2 Return
WARNING! Absolutely observe when shipping the instrument:
All instruments delivered to WIKA must be free from any kind of hazardous substances (acids, bases, solutions, etc.).
When returning the instrument, use the original packaging or a suitable transport package.
To avoid damage:
1. Wrap the instrument in an antistatic plastic lm.
2. Place the instrument, along with the shock-absorbent material, in the packaging.
Place shock-absorbent material evenly on all sides of the shipping box.
3. If possible, place a bag, containing a desiccant, inside the packaging.
4. Label the shipment as transport of a highly sensitive measuring instrument.
14 WIKA operating instructions mini limit switch, model LSO.02
13334591.02 10/2010 GB/D/F/E
10. Dismounting, return and disposal
Enclose the completed return form with the instrument.
The return form is available on the internet:
www.wika.de / Service / Return
10.3 Disposal
Incorrect disposal can put the environment at risk. Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance with the country-specic waste disposal regulations.
GB
13334591.02 10/2010 GB/D/F/E
WIKA operating instructions mini limit switch, model LSO.02 15
GB
16 WIKA operating instructions mini limit switch, model LSO.02
13334591.02 10/2010 GB/D/F/E
Inhalt
Inhalt
1. Allgemeines 18
2. Sicherheit 19
3. Technische Daten 22
4. Aufbau und Funktion 23
5. Transport, Verpackung und Lagerung 24
6. Inbetriebnahme, Betrieb 25
7. Wartung und Reinigung 26
8. Störungen 27
9. Garantie 28
D
10. Demontage, Rücksendung und Entsorgung 28
13334591.02 10/2010 GB/D/F/E
WIKA Betriebsanleitung Kleingrenzschalter, Typ LSO.02 17
1. Allgemeines
1. Allgemeines
Der in der Betriebsanleitung beschriebene Kleingrenzschalter wird nach den neuesten Erkenntnissen gefertigt. Alle Komponenten unterliegen während der Fertigung strengen Qualitäts- und Umwelt­kriterien. Unsere Managementsysteme sind nach ISO 9001 und ISO 14001 zertiziert.
D
Diese Betriebsanleitung gibt wichtige Hinweise zum Umgang mit dem Kleingrenzschal­ter. Voraussetzung für sicheres Arbeiten ist die Einhaltung aller angegebenen Sicher­heitshinweise und Handlungsanweisungen.
Die für den Einsatzbereich des Kleingrenzschalters geltenden örtlichen Unfallverhü­tungsvorschriften und allgemeinen Sicherheitsbestimmungen einhalten.
Die Betriebsanleitung ist Produktbestandteil und muss in unmittelbarer Nähe des Klein­grenzschalters für das Fachpersonal jederzeit zugänglich aufbewahrt werden.
Das Fachpersonal muss die Betriebsanleitung vor Beginn aller Arbeiten sorgfältig durchgelesen und verstanden haben.
Die Haftung des Herstellers erlischt bei Schäden durch bestimmungswidrige Verwen­dung, Nichtbeachten dieser Betriebsanleitung, Einsatz ungenügend qualizierten Fachpersonals sowie eigenmächtiger Veränderung am Kleingrenzschalter.
Es gelten die allgemeinen Geschäftsbedingungen in den Verkaufsunterlagen.
Technische Änderungen vorbehalten.
Weitere Informationen:
- Internet-Adresse: www.wika.de / www.wika.com
- zugehöriges Datenblatt: LM 31.01
- Anwendungsberater: Tel.: (+49) 9372/132-0 Fax: (+49) 9372/132-406 E-Mail: info@wika.de
Symbolerklärung
WARNUNG!
… weist auf eine möglicherweise gefährliche Situation hin, die zum Tod oder zu schweren Verletzungen führen kann, wenn sie nicht gemieden wird.
VORSICHT!
… weist auf eine möglicherweise gefährliche Situation hin, die zu gering­fügigen oder leichten Verletzungen bzw. Sach- und Umweltschäden führen kann, wenn sie nicht gemieden wird.
WIKA Betriebsanleitung Kleingrenzschalter, Typ LSO.0218
13334591.02 10/2010 GB/D/F/E
Loading...
+ 42 hidden pages