WIKA M93X.25 Specifications

R
Diaphragm-Type Sanitary Gauge Type M932.25 - Dry Case Type M933.25 - Liquid Filled Case
Applications
Pharmaceutical Industry Biotechnology
Food & Beverage
Standard Features
Diaphragm Seals
Diaphragm Seals
WIKA Datasheet M93X.25
Design
Process Connection
¾” & 1” Tri-Clamp
Pressure Ranges
1,200 psi maximum, limited by installed clamp rating
Operating Temperature
Media: +10°C to 100°C(standard) (>100°C available - consult factory) Stainless steel case with vent plug Ambient: +10°C to 60°C
Gauge Size 2½”, lower mount
Dial White aluminum with black lettering
Accuracy (Ref. 73°F)
±2/1/2% full span (ASME B40.100, Grade A)
Available Options (Connections, materials, etc.): See Selection Guide on page 3
Temperature Error (Ref. 73°F)
±1.3 psi / 18°F (10°C)
per ASME BPE, Type A
connection,
74-06
Fig. left M93X.25 Sanitary Gauge
Fig. right Clean Steam Assembly
Wetted Parts
316L SS, electro-polished RA < 15 µin (except weld seam)
System Fill (FDA Approved)
Glycerine, 99.7%: Non-vacuum applications Mineral Oil, Neobee M20, 350cST Food Grade Silicon Oil
Material Identication and Heat Numbers
Engraved in seal body or gauge case
Case Material
Polished stainless steel case with vent plug and stainless steel polished ring
Window
Standard polycarbonate Polysulfone available (with dry case & weep holes)
Serial Number
Engraved on back of case
Pointer
Black aluminum
WIKA Datasheet M93X.25 10/2017 Page 1 of 3
To determine the eects of temperature and response time in a specic application, contact the factory for an Application Questionnaire. The information provided will allow WIKA to accurately model your application parameters using computer simulation techniques.
Documentation
Calibration Conformance Report supplied with each assembly (not a direct substitute for NIST certicate). Material Conformance documents supplied with each assembly (not a substitute for 3.1 material certicate)
Available Options
See selection guide (over) Glyerine case ll External zero adjust Autoclaveable (dry case only, weepholes) Clean steam assembly with integral cooling element EPDM gasket (consult factory)
To determine the effects of temperature and response time in a specic
application, contact the factory for an Application Questionnaire. The information provided will allow WIKA Technical Support to accurately model your application parameters using state-of-the-art computer simulation techniques.
External Zero Adjustment
(optional)
Page 2 of 3 WIKA Datasheet M93X.25 10/2017
Loading...
+ 1 hidden pages