61833074GB.fm Page 1 Wednesday, July 5, 2006 11:19 AM
GB
The minimum distance between the support surface of the recipients on the cooking device and the lowest part of the hood must not be less
than 50 cm in case of electric cookers and 65 cm for gas or combination cookers. If the installation instructions for the gas cooker
specify a greater distance, this must be taken into account. Contact a qualified technician for installation. To install follow points
(1Ö2Ö3Ö.....).
Warni ng! Check whether the exhaust pipe and clamps are provided. If not, they must be purchased separately.
Preliminary steps for installing the hood
Pre-assemble the three parts of the flue support bracket with 4 screws. The width of the bracket must be identical to the internal width of the
telescopic flue.
For filter hoods, adjust the filter deflector, as shown in the enclosed diagram.
EXTRACTOR OR FILTERING HOOD INSTALLATION
Extractor Version: fumes are extracted and expelled to the outside through a fumes exhaust hose (A) fixed to the collar at the top of the
hood and secured with the special clamp (exhaust hose and fixing clamps are not supplied and must be bought separately).
Important! If the hood is equipped with a carbon filter, this must be removed.
The discharge air must not be ducted to a flue used for removing fumes produced by appliances using gas or other fuels, but must have a
separate outlet. All national regulations on air discharge must be observed.
Filtering Version: The air is filtered by a carbon filter and recycled into the surrounding environment by means of the deflector F.
Caution! If the hood is not equipped with a carbon filter, one must be ordered and fitted before use.
5019 618 33074
GB
61833074GB.fm Page 2 Wednesday, July 5, 2006 11:19 AM
For Filter Version only
5019 618 33074
20a Screws to be partially tightened.
Screw down fully only if the
decorative trim is not being fitted
GB