ARC 3090
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 07.04.2003 Subject to modification
Document-No.: 4812 731 15104
07.04.2003 / Page 2 ARC 3090 Whirlpool Europe
Doc. No: 4812 731 15104 8501 309 10000 Customer Service
Technical data
Factory Code RF 282 W
Dimensions
Height 159,0 cm
Width 55,0 cm
Depth 60,0 cm
Capacity
Total
gross 277 l
net 268 l
Cooling
gross 219 l
net 210 l
Freezing
gross 58 l
net 58 l
SERVICE
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Power consumption
in 24 hours 1,13 kWh
Freezing capacity
in 24 hours 3 kg
Compressor
Type NBM 1116 Y
Capacity (CECOMAF) 138 W
Refrigerant
Type R 600 a
Quantity 57 g
Thermostat switching value
Switch on temperature min. + 6,0 ˚C
Switch on temperature max. + 6,0 ˚C
Switch off temperature min. - 19,0 ˚C