Whirlpool APCGH1/NA, APCGH1/AR INSTRUCTION FOR USE

APCGH1 PRODUCT DESCRIPTION SHEET
GB IE
5019 619 61211
Operation of burners with
electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame setting .
with a star .
The spark plug gives out a spark that
causes the burner to ignite.
If the burner does not ignite, press the push-
button again.
Note:
Should particular local conditions of the
delivered gas make the ignition of the
burner difficult, it is advisable to repeat the
operation with the knob turned to the
small flame setting .
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Shaded circle Tap closed
Large flame Maximum opening/delivery
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
Type of
burner
Injector
marking
Rated
heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G 20
large
medium
small
12
8
94
76
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
NATURAL GAS
(Cylinder) G 30
large
medium
small
85
65
50
3.00
1.65
1.00
218 l/h
120 l/h
73 l/h
0.60
0.35
0.30
20
28-
30
35
NATURAL GAS
(Cylinder) G 31
large
medium
small
85
65
50
3.00
1.65
1.00
214 l/h
118 l/h
71 l/h
0.60
0.35
0.30
25 37 45
Type of gas
used
Appliance
model
Total rated
heat capacity
Pcs-kW
Total rated
consumption
Air required
for burning
m
3
/h
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Loading...