Whirlpool APCGH1/NA, APCGH1/AR INSTRUCTION FOR USE

APCGH1 PRODUCT DESCRIPTION SHEET
GB IE
1. Removable panstand grids 2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Shaded circle Tap closed Large flame Maximum opening/delivery
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame setting .
If the burner does not ignite, press the push­button again.
Small flame
Minimum opening or reduced delivery
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
5019 619 61211
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G 20
NATURAL GAS (Cylinder) G 30
NATURAL GAS (Cylinder) G 31
Type of gas used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6 G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6 G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of burner
large medium small
large medium small
large medium small
Appliance model
Injector marking
12
8 94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
218 l/h 120 l/h
73 l/h
214 l/h 118 l/h
71 l/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
Gas pressure
min. rat. max.
17 20 25
20
25 37 45
Air required for burning
m
28-
35
30
3
/h
Loading...