AKM 205 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids
2. Medium burner
3. Rapid electric hotplate
4. Large burner
5. Small burner
6. Medium burner control knob
7. Large burner control knob
8. Small burner control knob
9. Hotplate control knob
10. Electric hot plate operation lamp
Symbols
Shaded circle Tap closed
Large flame
and star
Small flame
Maximum opening/
delivery and
electronic ignition
Minimum opening
or reduced delivery
Operation of burners with electronic
ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time keep the knob pressed
against the control panel until the burner
ignites.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
— Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
5019 319 61371
Operation of the electric hotplate
• Set the knob to one of positions 1-6, which
correspond to different temperatures.
• To switch off the hotplate, set the knob to
position “0”.
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G 20
NATURAL GAS
(Groningue) G 25
LIQUID PETROLEUM
GAS
(Cylinder) G 30
LIQUID PETROLEUM
GAS
(Cylinder) G 31
Type of gas used Appliance model Total rated heat
G 20 20 mbar 3 gas + 1 E 5.65 538 l/h 11.3
G 25 25 mbar 3 gas + 1 E 5.24 581 l/h 10.5
G 30 28-30 mbar 3 gas + 1 E 5.65 411 g/h 11.3
G 31 37 mbar 3 gas + 1 E 5.65 403 g/h 11.3
burner
large
medium
small
large
medium
small
large
medium
small
large
medium
small
Injector
marking
128
94
76
128
94
76
85
65
50
85
65
50
Rated heat
capacity
Pcs-kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
capacity Pcs-kW
Rated
consumption
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated
consumption
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for
burning m3/h
ELECTRIC HOT PLATE POWER: 1500 W.
Gas pressure