Whirlpool AKM204/WH/01, AKM204/NB/01, AKM204/IX/01 INSTRUCTION FOR USE

AKM 204 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burner ignites.
After the burner ha signited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/flame delivery and electric and star ignition
Minimum opening or reduced delivery
Note:
- Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
5019 319 01021
Whirlpool is a registered trademark of Whirlpool USA
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of gas used Appliance model Total rated heat
G20 20 mbar 4 gas 7.30 695 l/h 14.6
G25 25 mbar 4 gas 6.77 751 l/h 13.5
G30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G31 37 mbar 4 gas 7.30 521 g/h 14.6
burner
large medium small
large medium small
large medium small
large medium small
Injector marking
H3 130
H2 98
X 72
F3 126
T8 96
F1 72
87 65 50
87 65 50
Rated heat capacity kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
capacity kW
Rated consumption
286 l/h 157 l/h
95 l/h
308 g/h 170 g/h 103 g/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Total rated consumption
Reduced heat capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure mbar
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
ELECTRIC SUPPLY: 230-240V - 50 Hz
Air required for burning m
3
/h
Loading...