Operation of burners with electronic ignition
To light one of the burners:
•Press the relative knob and turn it anti-
clockwise to the large flame and star setting .
•At the same time, keep the knob pressed against the control panel until the burner ignites.
•Release the knob.
If the burner does not ignite, repeat the operations described above.
1.Removable panstand grids
2.Medium burner
3.Rapid electric hotplate
4.Large burner
5.Small burner
6. Medium burner control knob
7. Large burner control knob
8. Small burner control knob
9. Electric hotplate control knob
10. Pilot lamp for electric hotplate
Symbols
Shaded |
Tap closed |
|
circle |
||
|
||
Large flame |
Maximum opening/ |
|
delivery and electronic |
||
and star |
||
ignition |
||
|
||
Small flame |
Minimum opening or |
|
reduced delivery |
||
|
Note:
—Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation
with the knob turned to the small flame setting .
Operation of the electric hotplate
•Set the knob to one of positions 1-6, which correspond to different temperatures.
•To switch off the hotplate, set the knob to position “0”.
5019 319 01012 |
Whirlpool is a registered trademark of Whirlpool USA |
|
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE |
|
|
|
|
|
|
CATEGORY II2E+3+ |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Type of gas used |
Type of |
Injector |
|
Rated |
Rated |
Reduced |
|
Gas pressure mbar |
||||||
|
|
burner |
marking |
|
heat |
consumption |
heat |
|
|
|
|
|||
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
capacity |
|
|
|
capacity |
|
min. |
rat. |
max. |
|
|
|
|
|
|
kW |
|
|
|
kW |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
large |
H3 130 |
|
3.00 |
|
286 l/h |
0.60 |
|
|
|
|
|||
medium |
H2 98 |
|
1.65 |
|
157 l/h |
0.35 |
17 |
20 |
25 |
|||||
(Methane) |
G 20 |
|
|
|||||||||||
small |
X 72 |
|
1.00 |
|
95 l/h |
0.30 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
large |
F3 126 |
|
2.78 |
|
308 l/h |
0.60 |
|
|
|
|
|||
medium |
T8 96 |
|
1.53 |
|
170 l/h |
0.35 |
20 |
25 |
30 |
|||||
(Groningue) |
G 25 |
|
|
|||||||||||
small |
F1 72 |
|
0.93 |
|
103 l/h |
0.30 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID |
|
large |
87 |
|
3.00 |
|
218 g/h |
0.60 |
|
|
|
|
||
PETROLEUM GAS |
medium |
65 |
|
1.65 |
|
120 g/h |
0.35 |
20 |
28-30 |
35 |
||||
(Cylinder) |
G 30 |
small |
50 |
|
1.00 |
|
73 g/h |
0.30 |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID |
|
large |
87 |
|
3.00 |
|
214 g/h |
0.60 |
|
|
|
|
||
PETROLEUM GAS |
medium |
65 |
|
1.65 |
|
118 g/h |
0.35 |
25 |
37 |
45 |
||||
(Cylinder) |
G 31 |
small |
50 |
|
1.00 |
|
71 g/h |
0.30 |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Type of gas used |
|
Appliance model |
Total rated heat |
|
Total rated |
|
Air required for |
|||||||
|
|
|
|
|
capacity kW |
|
|
consumption |
|
burning m3/h |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 20 20 mbar |
|
3 gas + 1 E |
|
5.65 |
|
|
538 l/h |
|
|
11.3 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 25 25 mbar |
|
3 gas + 1 E |
|
5.24 |
|
|
581 l/h |
|
|
10.5 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 25 28-30 mbar |
|
3 gas + 1 E |
|
5.65 |
|
|
411 g/h |
|
|
11.3 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
G 31 37 mbar |
|
3 gas + 1 E |
|
5.65 |
|
|
403 g/h |
|
|
11.3 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ELECTRIC HOTPLATE POWER: 1500 W.