Whirlpool AKM 202/WH, AKM 202/NB, AKM 202/IX INSTRUCTION FOR USE

AKM 202 PRODUCT DESCRIPTION SHEET
GB
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Shaded circle Tap closed Large Maximum opening/
flame delivery and electronic and star ignition
Small Minimum opening or flame reduced delivery
Operation of burners electronic ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burner ignites.
Release the knob.
If the burner does not ignite, repeat the operations described above.
5019 319 01219
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Typ e o f g as used
NATURAL GAS (Methane) G20
NATURAL GAS (Groningen) G25
LIQUID PETROLEUM GAS
(Cylinder) G30 LIQUID
PETROLEUM GAS (Cylinder) G31
Typ e o f burner
large medium small
large medium small
large medium small
large medium small
Injector marking
128
94 76
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
Rated consumption
286 l/h 157 l/h
95 l/h
308 l/h 170 l/h 103 l/h
218 l/h 120 l/h
73 l/h
214 l/h 118 l/h
71 l/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Typ e o f g as used
G20 20 mbar 4 gas 7.30 695 l/h 14.6 G25 25 mbar 4 gas 6.77 751 l/h 13.5 G30 28-30 mbar 4 gas 7.30 531 l/h 14.6 G31 37 mbar 4 gas 7.30 521 l/h 14.6
Appliance model
Total rated heat capacity Pcs-kW
Total rated consumption
Air required for burning
m
3
/h
Loading...