AKM 202 |
PRODUCT DESCRIPTION SHEET |
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
FR |
Operation of burners electronic ignition
To light one of the burners:
•Press the relative knob and turn it anti-
clockwise to the large flame and star setting .
•At the same time, keep the knob pressed against the control panel until the burner ignites.
•Release the knob.
If the burner does not ignite, repeat the operations described above.
1.Removable panstand grids
2-3. Medium burners
4.Large burner
5.Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Shaded circle |
|
|
|
|
Tap closed |
|
Large |
|
|
|
|
|
Maximum opening/ |
|
|
|
|
|||
|
|
|
|
|
||
flame |
|
|
|
|
|
delivery and electronic |
|
|
|
|
|
||
|
|
|
|
|||
and star |
|
|
|
|
ignition |
|
Small |
|
|
|
|
Minimum opening or |
|
|
|
|
|
|||
flame |
|
|
|
|
reduced delivery |
|
|
|
|
|
Note:
—Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the
operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance. |
|
|
|
|
|
|
|
|
|
||||||||
INJECTORS TABLE |
|
|
|
|
|
|
|
|
|
|
|
CATEGORY II2E+3+ |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of gas |
|
|
Type of |
|
Injector |
Rated |
|
Rated |
|
Reduced |
Gas pressure |
|
|||||
used |
|
|
burner |
|
marking |
heat |
|
consumption |
|
heat |
|
|
|
|
|
||
|
|
|
|
|
|
|
capacity |
|
|
|
|
capacity |
min. |
|
rat. |
max. |
|
|
|
|
|
|
|
|
Pcs-kW |
|
|
|
|
Pcs-kW |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
|
|
large |
|
128 |
|
3.00 |
|
286 l/h |
|
0.60 |
|
|
|
|
|
|
|
|
medium |
|
94 |
|
1.65 |
|
157 l/h |
|
0.35 |
17 |
|
20 |
25 |
|||
(Methane) |
G 20 |
|
|
|
|
|
|
||||||||||
|
small |
|
76 |
|
1.00 |
|
95 l/h |
|
0.30 |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
|
|
large |
|
128 |
|
2.78 |
|
308 l/h |
|
0.60 |
|
|
|
|
|
|
|
|
medium |
|
94 |
|
1.53 |
|
170 l/h |
|
0.35 |
20 |
|
25 |
30 |
|||
(Groningen) |
G 25 |
|
|
|
|
|
|
||||||||||
|
small |
|
76 |
|
0.93 |
|
103 l/h |
|
0.30 |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID |
|
|
large |
|
85 |
|
3.00 |
|
218 l/h |
|
0.60 |
|
|
|
|
|
|
PETROLEUM GAS |
|
medium |
|
65 |
|
1.65 |
|
120 l/h |
|
0.35 |
20 |
|
28-30 |
35 |
|||
(Cylinder) |
G 30 |
|
small |
|
50 |
|
1.00 |
|
73 l/h |
|
0.30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID |
|
|
large |
|
85 |
|
3.00 |
|
214 l/h |
|
0.60 |
|
|
|
|
|
|
PETROLEUM GAS |
|
medium |
|
65 |
|
1.65 |
|
118 l/h |
|
0.35 |
25 |
|
37 |
45 |
|||
(Cylinder) |
G 31 |
|
small |
|
50 |
|
1.00 |
|
71 l/h |
|
0.30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Type of gas |
|
|
Appliance |
|
|
Total rated |
|
Total rated |
|
Air required |
|
||||||
used |
|
|
model |
|
|
heat capacity |
|
consumption |
|
for burning |
|
||||||
|
|
|
|
|
|
|
Pcs-kW |
|
|
|
|
|
m3/h |
|
|
||
G 20 20 mbar |
|
|
4 gas |
|
|
7.30 |
|
|
695 l/h |
|
|
14.6 |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
G 25 25 mbar |
|
|
4 gas |
|
|
6.77 |
|
|
751 l/h |
|
|
13.5 |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
G 30 28-30 mbar |
|
4 gas |
|
|
7.30 |
|
|
531 l/h |
|
|
14.6 |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
G 31 37 mbar |
|
|
4 gas |
|
|
7.30 |
|
|
521 l/h |
|
|
14.6 |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5019 319 60141