AKM 201 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids
2. Medium burner
3. Rapid electric hotplate
4. Large burner
5. Small burner
6. Medium burner control knob
7. Large burner control knob
8. Small burner control knob
9. Electric hotplate control knob
10. Electric ignition button
11. Electric hot plate operation lamp
Symbols
Shaded circle Tap closed
Large flame
Small flame
Maximum opening/
delivery
Minimum opening or
reduced delivery
Operation of burners
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame setting .
• At the same time, press the push-button with a
star .
The spark plug gives out a spark that causes
the burner to ignite.
If the burner does not ignite, press the push-button
again.
Note:
— Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
Operation of the electric hotplate
• Set the knob to one of positions 1-6, which
correspond to different temperatures.
• To switch off the hotplate, set the knob to
position “0”.
Whirlpool is a registered trademark of Whirlpool USA

DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31
Type of gas used Appliance model Total rated heat
G20 20 mbar 3 gas + 1 E 5.65 538 l/h 11.3
G25 25 mbar 3 gas + 1 E 5.24 581 l/h 10.5
G30 28-30 mbar 3 gas + 1 E 5.65 411 g/h 11.3
G31 37 mbar 3 gas + 1 E 5.65 403 g/h 11.3
burner
large
medium
small
large
medium
small
large
medium
small
large
medium
small
Injector
marking
H3 130
H2 98
X 72
F3 126
T8 96
F1 72
Rated
heat
capacity
kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
87
1.65
65
1.00
50
3.00
87
1.65
65
1.00
50
capacity kW
Rated
consumption
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure mbar
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for
burning m
ELECTRIC SUPPLY: 230-240V - 50 Hz
ELECTRIC HOT PLATE POWER: 1500 W.
3
/h
5019 319 01019