Whirlpool AKM 201/TF, AKM 201/IX, AKM 201/WH INSTRUCTION FOR USE

AKM 201 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids
2. Medium burner
3. Rapid electric hotplate
4. Large burner
5. Small burner
6. Medium burner control knob
7. Large burner control knob
8. Small burner control knob
9. Electric hotplate control knob
10. Electric ignition button
11. Electric hot plate operation lamp
Symbols
Shaded circle Tap closed
Large flame
Small flame
Maximum opening/ delivery
Minimum opening or reduced delivery
Operation of burners
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame setting .
At the same time, press the push-button with a star . The spark plug gives out a spark that causes the burner to ignite.
If the burner does not ignite, press the push-button again.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
Operation of the electric hotplate
Set the knob to one of positions 1-6, which correspond to different temperatures.
To switch off the hotplate, set the knob to position “0”.
Whirlpool is a registered trademark of Whirlpool USA
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of gas used Appliance model Total rated heat
G20 20 mbar 3 gas + 1 E 5.65 538 l/h 11.3
G25 25 mbar 3 gas + 1 E 5.24 581 l/h 10.5
G30 28-30 mbar 3 gas + 1 E 5.65 411 g/h 11.3
G31 37 mbar 3 gas + 1 E 5.65 403 g/h 11.3
burner
large medium small
large medium small
large medium small
large medium small
Injector marking
H3 130
H2 98
X 72
F3 126
T8 96
F1 72
Rated heat capacity kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
87
1.65
65
1.00
50
3.00
87
1.65
65
1.00
50
capacity kW
Rated consumption
286 l/h 157 l/h
95 l/h
308 l/h 170 l/h 103 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Total rated consumption
Reduced heat capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure mbar
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for burning m
ELECTRIC SUPPLY: 230-240V - 50 Hz ELECTRIC HOT PLATE POWER: 1500 W.
3
/h
5019 319 01019
Loading...