Whirlpool AKM 176/WH, AKM 176/IX INSTRUCTION FOR USE

3gb66002.fm5 Page 1 Friday, October 19, 2001 12:16 PM
AKM 176 PRODUCT DESCRIPTION SHEET
HU
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Double crown burner
7.
Medium burner control knob
8.
Medium burner control knob
9.
Double crown control knob
10.
Large burner control knob
11.
Small burner control knob
Symbols
Operation of burners with safety device
and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
At the same time, keep the knob pressed
against the control panel until the burner
ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
Shaded
circle
Large
flame
and star
Small
flame
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening
or reduced delivery
USING THE DOUBLE-RING BURNER
When using the double-ring burner, leave the knob
on the maximum setting (large flame ) for at
least five minutes after lighting before selecting a
lower setting.
5019 319 66002 1101858
3gb66002.fm5 Page 2 Friday, October 19, 2001 12:16 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: The distance A between the wall cabinets must be a minimum of 900 mm. In case
of installation of a hood above the cooktop, please refer to the hood instructions
for the correct distance.
INJECTORS TABLE CATEGORY II2HS3B/P
Type of
gas used
NATURAL GAS
(Methane) G 20
NATURAL GAS
(Methane) G 25.1
LIQUID
PETROLEUM GAS
(Cylinder) G 30
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Type of
gas used
Type of
burner
large
medium
small
double crown
large
medium
small
double crown
large
medium
small
double crown
large
medium
small
double crown
Appliance
model
122
90
74
132
129
99
78
139
85
65
50
92
85
65
50
92
Rated heat
capacity
Pcs-kW
3.00
1.65
1.00
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
3.30
3.00
1.65
1.00
3.30
Injector
marking
Total rated heat
capacity
Pcs-kW
Rated
consumption
286 l/h
157 l/h
95 l/h
314 l/h
332 l/h
183 l/h
111 l/h
365 l/h
218 g/h
120 g/h
73 g/h
240 g/h
214 g/h
118 g/h
71 g/h
236 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.30
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
1.50
0.60
0.35
0.30
1.50
G 20 25 mbar 5 gas 10.6 1009 l/h 21.2
G 30 30 mbar 5 gas 10.6 771 g/h 21.2
G 31 37 mbar 5 gas 10.6 757 g/h 21.2
G 25.1 25 mbar 5 gas 10.6 1174 g/h 21.2
Gas pressure
min. rat. max.
20 25 33
20 25 33
24 30 36.5
25 37 45
Air required for
burning
3
/h
m