S E R V I C E |
Whirlpool Europe |
AWZ 220 |
Customer Services |
Service Manual
Tumble dryer
Air Vent
AWZ 220
Model |
AWZ 220 |
|
Version |
8575 220 15000 |
Page |
|
Technical data |
2 - 3 |
|
Spare part list |
4 |
|
Exploded view |
5 - 6 |
|
Wiring diagram |
7 |
|
Circuit diagram |
8 |
|
Program diagram |
9 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 02.06.2000 |
Subject to modification |
Document-No.: 4812 713 12025 |
|
02.06.2000 / Page 2 |
AWZ 220 |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 713 12025 |
8575 220 15000 |
Customer Service |
||
|
|
|
|
|
Technical data
Dimensions |
|
|
|
Height |
|
85 |
cm |
Width |
|
59.5 |
cm |
Depth |
|
56 |
cm |
Weight |
|
|
|
Gross weight |
|
33 |
kg |
Net weight |
|
31 |
kg |
Surroundings temperature |
|
|
|
Max.room temperature |
35 |
˚C |
|
Min. room temperature |
5 |
˚C |
|
Humidity |
|
|
|
Max. relative humidity |
95 |
% |
|
Power connection |
|
|
|
Voltage |
|
230 |
V |
Frequency |
|
50 |
Hz |
Connected load |
|
2.8 |
kW |
Fuse |
|
16 |
A |
Drum data |
|
|
|
Volume |
|
104 |
l |
Drum speed |
|
56 ± 3 |
rpm |
Airflow |
|
120-160 |
m3 /h |
Capacity of laundry |
|
|
|
Cotton max. |
|
5 |
kg |
Easy care max. |
|
2.5 |
kg |
Electrical components |
|
|
|
Heating |
|
|
|
Type |
Aluminium mass heating |
||
Nominal voltage |
|
230 +10% / -15% V |
|
Nominal power |
|
2500 ± 5% |
W |
Heating resistances: |
|
Ω |
|
Connectin points |
|
23.5-28 |
Thermostats
Caution:
If one of the thermostats (TL, TH1.2) is defective, the whole heating element has to be changed for safety reason !
Therefore, the thermostats are not available as separate spare parts !
Safety thermostat (in heater) TL |
|
|
|
||
Switch off temperature |
298 |
–10 |
˚C |
||
Heat resistance of solder |
260 |
|
˚C |
||
Fluff thermostat (in heater) TH 1.2 |
|
|
|||
Switch off temperature |
220 |
± 7.5 |
˚C |
||
Hysteresis |
|
12 - 25 |
K |
||
Exhausting thermostat (in airchannel) TH 1.1 |
|||||
Switch on temperature |
38 |
± 5 |
˚C |
||
Switch off temperature |
53 |
± 4 |
˚C |
||
Timer |
|
|
|
|
|
Type |
Electromechanical Timer |
|
|||
|
Eaton EC 4605 |
|
|
|
|
Nominal voltage |
230 |
+10% / -15% V |
|||
Frequency |
|
50 |
|
|
Hz |
Number of steps |
60 |
|
|
|
|
Stop |
|
01 |
|
|
|
Heating (138 min.) |
02 |
- |
53 ( |
|
|
Cool down (6 min.) |
54 |
- |
55 |
|
|
Anticreasing (12 min.) |
56 |
- |
59 |
|
|
Stop |
|
60 |
|
|
|
Reversing cycle |
|
2‘-6‘-2‘-80‘ |
|
||
Ambient temperature |
5 to 70 |
˚C |
|||
Storage temperature |
-30 to 85 |
˚C |
|||
Mainand blower motor |
|
|
|
|
|
Type |
1-phase asynchronous |
||||
Nominal voltage |
230 |
+10% / -15% V |
|||
Frequency |
|
50 |
|
|
Hz |
Power consumption |
295± 7% |
W |
|||
Resistances of coils: |
24.7± 7% |
Ω |
|||
Main coil (2-3) |
|
||||
Auxiliary coil (2-1) |
25.6± 7% |
Ω |
|||
Rated speed with 5 kg laundry |
|
|
|
||
and 100% rest humidity |
2730 |
rpm |
|||
Capacitor (470 V) |
10± 7% |
μ F |
S E R V I C E
Technical data
Whirlpool Europe |
AWZ 220 |
02.06.2000 / Page 3 |
Customer Service |
8575 220 15000 |
Doc. No: 4812 713 12025 |
|
|
|
Push buttons |
|
|
|
Gentle switch SG |
|
|
|
Nominal voltage |
|
230 +10% / -15% |
V |
Nominal current |
|
16 |
A |
Start / door switch |
|
|
|
Start switch SST |
|
|
|
Nominal voltage |
|
230 +10% / -15% |
V |
Nominal current |
|
16 |
A |
Door switch SD |
|
|
|
Nominal voltage |
|
230 +10% / -15% |
V |
Nominal current |
|
16 |
A |
Buzzer |
|
|
|
Type |
|
Eichhoff E 2778 |
|
Nominal voltage |
|
230 +10% / -15% |
V |
Resistance of coil |
|
7 ± 15 % |
KΩ |
Radio interference filter |
|
|
|
Typ |
ISKRA KPB 7325 |
|
|
Voltage max. |
275 |
V |
|
Capacity |
0.1 μ F X1 + 2 x 0.022 μ F Y2 + 1MΩ |
|