Whirlpool 575 220 01014 Service Manual

SERVICE
Model AWZ 220 Version 8575 220 01014 Page
Whirlpool Europe Customer Services
AWZ 220
Tumble dryer Air Vent AWZ 220
Technical data 2 - 3
Spare part list 4
Exploded view 5 - 6
Wiring diagram 7
Circuit diagram 8
Program diagram 9
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 21.11.2003 Subject to modification Document-No.: 4812 713 13663
21.11.2003 / Page 2 AWZ 220 Whirlpool Europe Doc. No: 4812 713 13663 8575 220 01014 Customer Service
Technical data
SERVICE
Dimensions
Height 85 cm Width 59.5 cm Depth 56 cm
Weight
Gross weight 33 kg Net weight 31 kg
Surroundings temperature
Max.room temperature 35 ˚C Min. room temperature 5 ˚C
Humidity
Max. relative humidity 95 %
Power connection
Voltage 230 V Frequency 50 Hz Connected load 2.8 kW Fuse 16 A
Thermostats
Caution:
If one of the thermostats (TL, TH1.2)
is defective, the whole heating element has to be changed for safety reason !
Therefore, the thermostats are not
available as separate spare parts !
Safety thermostat (in heater) TL
Switch off temperature 298 -10 ˚C Heat resistance of solder 260 ˚C
Fluff thermostat (in heater) TH 1.2
Switch on temperature 195 ± 7.5 ˚C Switch off temperature 220 ± 7. 5 ˚ C
Exhausting thermostat (in bottom) TH 1.1
Type ELTH 261P Switch on temperature 38 ±C Switch off temperature 53 ±C
Timer
Drum data
Volume 104 l Drum speed 56 ± 3 rpm Airflow 120-160 m
Capacity of laundry
Cotton max. 5 kg Easy care max. 2.5 kg
Exhaust hose
Inner diameter 10 cm Maximum allowable length (with 2 bows) 4 m
Electrical components
Heating
Type Aluminium mass
heating Nominal voltage 230 +10%/-15% V Nominal power 2500 ± 5% W Heating resistances: Connection points 19.5 - 23
Type Electromechanical
Timer Eaton EC 4605
3
/h
Nominal voltage 230 +10% / -15% V Frequency 50 Hz Number of steps 60 Stop 01 Heating (138 min.) 02 - 53 Cool down (6 min.) 54 - 55 Anticreasing (12 min.) 56 - 59 Stop 60 Reversing cycle 2’- 6’- 2’- 80’
Ambient temperature 5 to 70 ˚C Storage temperature up to 85 ˚C
Main- and blower motor
Type 1-phase asynchronous Nominal voltage 230 +10%/-15% V Frequency 50 Hz Power consumption 295 ± 7% W
Resistances of coils:
Main coil (2-3) 24.7 ± 7% Auxiliary coil (2-1) 25.6 ± 7% Rated speed with 5 kg laundry and 100% rest humidity 2730 rpm Capacitor 10 ± 7% µ F
Whirlpool Europe AWZ 220 21.11.2003 / Page 3
SERVICE
Customer Service 8575 220 01014 Doc. No: 4812 713 13663
Technical data
Radio interference filter
Type ISKRA KPB 7325 Voltage max. 275 V Capacity 100 nF X1 + 2x 22 nF Y2 1M
Push buttons
Gentle switch SG
Nominal voltage 230 +10% / -15% V Nominal current 16 A
Start / door switch
Start switch SST
Nominal voltage 230 +10% / -15% V Nominal current 16 A
Door switch SD
Nominal voltage 230 +10% / -15% V Nominal current 16 A
Loading...