S E R V I C E |
Whirlpool Europe |
AWZ 220 |
Customer Services |
Service Manual
Tumble dryer
Air Vent
AWZ 220
Model |
AWZ 220 |
|
Version |
8575 220 01011 |
Page |
|
Technical data |
2 - 3 |
|
Spare part list |
4 |
|
Exploded view |
5 - 6 |
|
Wiring diagram |
7 |
|
Circuit diagram |
8 |
|
Program diagram |
9 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 23.08.2002 |
Subject to modification |
Document-No.: 4812 713 12751 |
|
23.08.2002 / Page 2 |
AWZ 220 |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 713 12751 |
8575 220 01011 |
Customer Service |
||
|
|
|
|
|
Technical data
Dimensions
Height |
85 |
cm |
Width |
59.5 |
cm |
Depth |
56 |
cm |
Weight |
|
|
Gross weight |
33 |
kg |
Net weight |
31 |
kg |
Surroundings temperature |
|
|
Max.room temperature |
35 |
˚C |
Min. room temperature |
5 |
˚C |
Humidity |
|
|
Max. relative humidity |
95 |
% |
Power connection |
|
|
Voltage |
230 |
V |
Frequency |
50 |
Hz |
Connected load |
2.8 |
kW |
Fuse |
16 |
A |
Drum data |
|
|
Volume |
104 |
l |
Drum speed |
56 ± 3 |
rpm |
Airflow |
120-160 |
m3 /h |
Capacity of laundry |
|
|
Cotton max. |
5 |
kg |
Easy care max. |
2.5 |
kg |
Exhaust hose |
|
|
Inner diameter |
10 |
cm |
Maximum allowable |
|
|
length (with 2 bows) |
4 |
m |
Electrical components |
|
|
Heating |
|
|
Type |
Aluminium mass |
|
|
heating |
|
Nominal voltage |
230 +10%/-15% V |
|
Nominal power |
2500 ± 5% |
W |
Heating resistances: |
|
Ω |
Connection points |
19.5 - 23 |
Thermostats
Caution:
If one of the thermostats (TL, TH1.2) is defective, the whole heating element has to be changed for safety reason !
Therefore, the thermostats are not available as separate spare parts !
Safety thermostat (in heater) TL |
|
||
Switch off temperature |
298 -10 |
˚C |
|
Heat resistance of solder |
260 |
˚C |
|
Fluff thermostat (in heater) TH 1.2 |
|
||
Switch on temperature |
195 ± 7.5 |
˚C |
|
Switch off temperature |
220 ± 7.5 |
˚C |
|
Exhausting thermostat (in bottom) TH 1.1 |
|||
Switch on temperature |
38 |
± 5 |
˚C |
Switch off temperature |
53 |
± 4 |
˚C |
Timer |
|
|
|
Type |
Electromechanical |
||
|
Timer |
|
|
|
Eaton EC 4605 |
||
Nominal voltage |
230 +10% / -15% V |
||
Frequency |
50 |
|
Hz |
Number of steps |
60 |
|
|
Stop |
01 |
|
|
Heating (138 min.) |
02 |
- 53 |
|
Cool down (6 min.) |
54 |
- 55 |
|
Anticreasing (12 min.) |
56 |
- 59 |
|
Stop |
60 |
|
|
Reversing cycle |
2’- 6’- 2’- 80’ |
|
|
Ambient temperature |
5 to 70 |
˚C |
|
Storage temperature |
up to 85 |
˚C |
|
Mainand blower motor |
|
|
|
Type |
1-phase asynchronous |
||
Nominal voltage |
230 +10%/-15% V |
||
Frequency |
50 |
|
Hz |
Power consumption |
295 ± 7% |
W |
|
Resistances of coils: |
24.7 ± 7% |
Ω |
|
Main coil (2-3) |
|||
Auxiliary coil (2-1) |
25.6 ± 7% |
Ω |
|
Rated speed with |
|
|
|
5 kg laundry |
|
|
|
and 100% rest humidity |
2730 |
rpm |
|
Capacitor |
10 ± 7% |
μ F |
S E R V I C E
Technical data
Whirlpool Europe |
AWZ 220 |
23.08.2002 / Page 3 |
Customer Service |
8575 220 01011 |
Doc. No: 4812 713 12751 |
|
|
|
Push buttons |
|
|
|
Gentle switch SG |
|
|
|
Nominal voltage |
230 |
+10% / -15% |
V |
Nominal current |
16 |
|
A |
Start / door switch |
|
|
|
Start switch SST |
|
|
|
Nominal voltage |
230 |
+10% / -15% |
V |
Nominal current |
16 |
|
A |
Door switch SD |
|
|
|
Nominal voltage |
230 |
+10% / -15% |
V |
Nominal current |
16 |
|
A |
Buzzer |
|
|
|
type |
Eichhoff E 2778 |
|
|
Nominal voltage |
230 |
+10%/ -15% |
V |
Resistance of coil |
7 ± 15 % |
kΩ |
|
Radio interference filter |
|
|
|
Type |
ISKRA KPB 7325 |
|
|
Voltage max. |
275 |
|
V |
Capacity |
100 nF X1 + 2x 22 nF Y2 1MΩ |
|