This section contains instructions for installation
WDI002S-WX2
being installed internally,
Controller Board in the closest available expansion slot.
Handle the controller board
board. Some
damage may occur if the board
Instructions
(S-WX2) board. If the disk drive(s) are
of
it
CAUTION
the chips
is best to locate the S-WX2
by
the ends of the
are
static sensitive and
is
incorrectIy
of
the
handled.
At this time, verify that the
ler board are correct. Refer to pages 9 and
ment for information on the
Next, remove the blank expansion slot bracket.
bracket away and save
will be used to hold the new controller board
Connect the 34-pin (wide control cable) connector to J
the
S-WX2 board. Make sure that Pin I
nector goes to
cable connector
of
the cable.
ect
Conn
nector) on the controller board. Make sure that
cable
is
If
a second drive
data cab le to
At this time, also verify that the disk drive(s)
installed. This includes correct placement
jumpers
drive installation manual for further instructions.
NOT
USE
Install the controller board into the expansion slot. Make
sure that the board
both ends
screw.
Pin I on the controller board. Pin I
is
typically located on the col
the 20-pin (data cable) to J2 (Drive 0 Data Con-
connected to Pin I on the controller board.
is
13
likewise.
and drive terminator installation . Refer to the disk
THE
RADIAL
of
the board. Secure the board with the bracket
jumper
settings on the control-
10
of
jumper
settin gs.
it
for possible future use.
being installed, connect the Drive 1
SELECT
is
seated properly by pressing down on
CAUTION
OPTION.
this docu-
The
in
place.
of
the cab le con-
or
coded side
Pin I on the
is
properly
of
drive select
Put the
screw
of
I on
the
00
When routing the cables, be careful not to pinch
them. Cables must not get caught between the
cover and the boards nor should they obstruct
any
air
flow path from fans
Install the disk drive(s) per manufacturer
or
vents.
's
instructions.
Standard
The following procedures are a complete set
for
WDI002S-WX2
ROM.
Running the OE
The
program to physically format the drive. During execution,
the user
refer to the DOS operating manual for detailed instructions
regarding this utility.
BIOS
ROM
Format
formatting
(P
DEBUG Utility
one
or
two
Controller Board with a standard BIOS
/N 62-0000 42-xxx).
BUG
Utility
is
used to initiate the S-WX2 format
is
prompted to define the interleave factor. Please
Instructions
disk
drive
s when usin g a
of
instructions
Step Instructions
1.
At the A> prompt, load and run the DOS debug utility
by typing DEBUG followed by
stands for carriage return
A> DEBUG CR
The
next step changes the drive address a
lf
leave factor.
to
00
and the interleave factor will default to three. Proceed
with step 2
the system
than three.
2.
Atthe
target drive number and interleave factor.
prompt
not modified, the drive number will default
if
there are two hard disk drives configured into
and/
or
the desired interleave factor
lf
neither applies, go directly to step
debug prompt, type the following line to se
is
the hyphen "
-".
- rax CR
CPU response:
AX
0000
At the colon prompt, enter drive number and inter-
leave factor
in
hexidecimal followed by
xxyy CR
Where: xx = the relative drive number
yy
= the interleave factor
NOTE: Relative Drive
01.
An
interleave
formatting two drives, this operation must be run
twice; first with the relative drive number
again with
3. At the debug prompt, initiate the S-WX2 format program by typing in the following
it
=
C: = 00
factor
Ol.
-g
= c800:5 CR
aRETURN. "CR
or
ENTER.
nd
sector inter-
is
aRETURN
, Relative Drive 0 : =
of
03
is
standard. If
command
to be other
3.
tthe
The
debug
=
00
and
line.
The
S-WX2
following :
WX2 Format Revision 7.0
1985
(AH) = Relati
(AL) =
Press
"Y"
Before responding, please remember
data
on the target drive will be lost du ring execu-
format
Interleave factor
to begin formatting drive
program
(C) Copyright Western Digital Corp.
ve
dri
ve
number (0·7)
CAUTION
(3
is
XX
standard)
will
display
with interleave
that
the
YY
all
tion of the format program. Hit any other key to
abort
the format program and save the data.
4. Press "Y"
the drive.
"
System responses:
If
displays the
tor
CPU
Nothing done exit
A>
If
program can take up to five minutes. If there are no
resulting errors, the program displays the following
message and returns the operator to
CPU
Format Successful
A>
If
.
immediately terminate, display the following error
message, and return the operator to DOS. XX is the
hexidecimal
page 8.
CPU
Error
A>
If
through 5 with the relative drive number equal to
Otherwise, continue with st
5. Load and execute the
Refer to your
FDlSK
fol
lowed by
any key
to DOS .
"Y" is typed, formatting is initiated. The format
an error occurs whi le formatting , the program will
a second drive
other
fo
response:
response:
S-WX2 BIOS completion code. Refer to
response:
.•. -co
mpletion code
and FORMAT.
aRETURN
Y
than " Y"
llowing message a
XX
is
to be formatted, repeat steps
FDlSK and FORMAT uti lities.
DOS manual for more information on
to beg
CR
is
typed , the program
nd
returns the opera-
DOS .
ep
5.
in
formatting
0 I.
2
3
Page 2
Auto-Config
Option
This section contains instructions for performing the low
level
or
physical format
of
one
or
two ST506/ST412
Winchester disk drives when using Western Digital's
WDI002S-WX2 controller board, an Auto-Config BIOS
and
ROM,
62-0000
its resident Auto-Config
43-xxx).
sof
tware. (P/N
Auto-Config has four formatting options as folIows:
1.
Format
tering the drive
one
or
two physical drive(s) by en-
parameters
and
bad
track
list via
the keyboard.
2.
Format
drives by entering the drive
der
one physical drive as two virtual
parameters,
partition values,
and
bad
track
cylin-
list via the
keyboard.
3.
Format
the drive tables selected by SW1. The bad
list
4.
Format
one or two physical drive(s) by using
is
entered via the keyboard.
one physical drive as two virtual
track
drives by using the drive tables. Virtual cylinder
partition values
and
bad
track
list
are
entered via
the keyboard.
Drive
Parameters
Drive parameters that have to be established during the
format procedure include the maximum number
ders, maximum number
of
heads, cylinder for reduced
of
cylin-
write current, cyli nder for write preco mpensation, error
burst length , and
Auto-Config supports keyboard entry
It
also supports the pre-programmed drive table entry
parameter
A single
of
jumper
drive
CCS opti
on byte -step rate.
of
these parameters.
s.
chooses between keyboard entry or the use
tables.
The
ability to
enter
co nfi gu ration
of
informatio n from the keyboard may be disabled by placing
jumper
on SW 1
-5
of
a
drive tables are selected by
Virtual
Formatting
the controller board. I f disabled , the
SWl-l
to SWI-4. See page 9.
Auto-Config supports virtua l drive formatting. Virtual
drive formatting
is
a method by which one physical drive
is
split into two logical or virtual drives. The virtual drives
are referenced as Drive
Current vers ions
per drive. Therefore, a
into two virtual drives using the virtu
following table
C:
and Drive D:.
of
DOS allow no more than 32 megabytes
40 megabyte drive may be divided
al
provid~s
an example
option. The
of
how to calculate
total drive capacity and es tablish virtual parameters.
The capacity
(#Cy
If
a drive has 6 12 cylinders, 8 heads, 17 sectors per track a
a 512 byte sector size, then calculate the logical sp l
folIows:
To split the drive into 210gical drives
each
Because (X)(heads)(sectors/track)(sector size)
= 30 megabytes.
Note:
Note: Round X down to the nearest whole number.
Since Y = Total capacity - X
If
this option is chosen, a second physical drive may not be
of
a drive can be easily calculated as folIows:
Capacity =
l.)(#Heads)
of
X and Y respectively, do the follow ing calculation
I megabyte = 20'0 bytes = 1,048,576 bytes.
(#Sec
tors/Track)(Sector Size in Bytes)
Total capacity = 42,614,784 bytes
(612)(8)(17)(512)
of30
and
X = (31,457,280)/(8)(17)(
X = 451.8 = 45] cylinders
Y =
612 -451
The split =
Logical
Format
512)
or
161
451
161
Calculation
or
10
megabytes
nd
it
as
s.
installed on the S-WX2 since DOS will only support two
drives. The ability to virtua
disabled
Low Level
The
by
placing a
Format
low level format
ll
y configure a drive may be
jumper
on
is
runju
st once on a drive that
SWI-6
(page 9).
is
to be
virtually configured. However, the DOS FDISK and
FORMAT utilities must be run on both logical drives.
If
two physical drives are to be formatted, the low level
format
is
run on each drive . As before, the DOS FDISK and
FORMAT utilities are run on each drive .
Auto-Config
The
following instructions contain a detailed step by step
description
Conf
ig procedures.
Formatting
of
the actions required to execute the Auto-
Procedures
Step Instructions
1.
Verify
jumper
settings. Refer to pages 9 and 10.
2. Load and execute the debug utility.
3. At the debug prompt, initiate the S-WX2 format program by typing the following command line. The
debug prompt
is
the hyphen
-g
= c800:5
"-"
.
CR
4. The S-WX2 format program will display the following
message:
WX2
Format
1985
Ke
y in drive no
Ent
Revision 1'.8 (C) Copyright Western Digital Corp.
and
interleave as folIows: d
no (0-1
ve
factor
ii
separated by
)
(1-16)
aspace
and followed with a
er
= relative
d
ii
= interlea
d and
ii
where
RETURN.
EXAMPLE:
o
03
CR
NOTE: Drive
factor
option must be run twice; once with d
with d
5.
The
following message will be displayed.
Key in disk characteristics as folIows: cce h
eec
= total
=
h
rrr
= s
ppp
= write precomp cylinder (
ee = max correctable e
00
=
Ent
er
each value separated by
comp
lete entry with
C:
of 3 is
= I.
number
tarting
CC
= 0, Drive
standard. If formatting two drives, thi s
number
of cylinder
of
heads
reduced
B option byte (I hex digit )
D: = I.
s (
(1-2
digits)
write
eylinder (1-4 digit
1-4
rror
bur
st length
1-4
digit
rrr
digits)
s)
aspace and
aRETURN.
An interleave
= 0 and agai n
ppp
ee
00
where
s)
(1-2
digit
s)
follow the
EXAMPLE:
306 4
128
128
11
5CR
6. CPU response:
Are you virtually configuring the drive - Answer Y/N
Ent
er
a "Y" and RETURN for yes or "N" and RE-
TURN
for no.
Y CR or N CR
7. If Yes, the followin
Key
in virtual drive size list as vvvv _
where vvvv =
Enter two cylinder numbers, separated by
followed by a RETURN. See page
NOTE: The sum
the maximum number
virtual
g message
drive s
ize (1-4
is
displayed.
..
digit
s)
5.
of
these two numbers cannot exceed
of
available cylinder
aspace
s.
and
4
5
6
Page 3
EXAMPLE
If
no, continue to next ste
:
153
153CR
p.
8. The following message will be displayed.
Press "y" to begin formatting drive d with interleave ii.
NOTE: d = relative drive
numb
er and
ii
= int e
factor.
"Y" followed by
Type
aRETURN
.
Y CR
System responses:
9.
If
any key
displays the following message and returns the operator to
CPU
Nothing done exit -
A>
If
an error occurs while form atting, the program will
imm
message, and return the operator to
hexidecimal S-
8.
CPU
Error
A>
If
"
Y"
resulting errors, the program displays the following
message.
CPU
00
you want
Th
e use r should type "Y" and a
and
Th
e us
track list.
manufacturer.
procedure
Because
ing an
ical address being marked bad . As
accept a limited
sive media de fects may cau se the
to
terminale
call
y, "TRACK
other
than
"Y" is
typ
ed, the
program
DOS.
respons
e:
returning
to system
...
ediatel y terminate, di splay the following error
DOS.
XX
WX2 BlaS
completion code. See page
response:
....
completion code
is typed, formatting is
XX
initiated.
~
lf
there are no
response:
to
format bad tracks - answer Y/N
RETURN
aRETURN
er
for no.
Y
CR
or
N CR
is prompted to enter, via the keyboard, a bad
This li
st should be provided by the drive
for yes ; "N"
However, due to DOS limitations, this
is not reco
of
the logical addressing used by DOS , mark-
entir
e track bad will result in
mmended
.
mor
e than one log-
DOS can only
number
of
def
ects, a drive with exces-
FORMAT
with an error.
00
BAD -
The
displayed error is typi-
DRIVE
UNUSABLE
7
rl
eave
is the
pro gram
."
As a recommended alternative, execution
utility
program
FORMAT
should correctly locate and
deallocate all media defects.
10.
lf
yes, the following message is displayed .
Key
in bad track list as
where
ccc
= bad
h
track
= bad track head number(I·2 digits)
Type is the
track
s, separate them with spaces, and follow with a
RETURN
EXAMPLE
.
:
160 1 161
The
bad track message will be displayed again. To
terminate bad track
folIows:
ccc
cylinder no (1·4 digits)
cylinder
and head numbers for the bad
1 304 3
entr
223 4 223
y,
h .
type "N" follow ed by a
RETURN.
N CR
11.
The
following message is displayed .
Format Successful - Returning to system
If a second
12
12. Load and
driv
with d = 01.
Exe
TIES. Refer
e is to be formatted, repeat step s 2 through
Otherwi
se, continu e with step 12.
cute the
to
your
FDISK
DOS
information on the se utilities.
CODES
01
02
04
OS
07
09
OB
10
11
20
40
80
BB
FF
COMPLETION
CODE
SUMMARY
Bad Command
Address Mark Not Found
Sector Not Found
Reset Fa