Westermo Lynx-x05-S1 User Manual

User Guide
6643-2230
WeOS
Lynx DSS
Westermo Teleindustri AB
©
Industrial Ethernet
5-port Device Server Switch
www.westermo.com
Software tools
Related software tools are available in the folder software tools under technical support on the Westermo website.
License Information
This device contains public available software which is under the GPL license. For more information see legal.pdf included with all firmware releases. This product includes software developed by the OpenSSL Project for use in the
OpenSSL Toolkit. http://www.openssl.org
Legal information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6643-2230
Safety
! !
Before installation:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from all power supply. Ensure compliance to national installation regulations. This unit uses convection cooling. Make sure that the unit is installed such as its ambient temperature is within its specified maximum/minimum temperature.
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from all power supply.
WARNING
Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm². Note that this unit can be connected to two different power sources. When this unit is operated at an ambient temperature above +55°C (+131°F), the External Surface of Equipment may exceed Touch Temperature Limit according to EN/IEC/UL 60950-1. To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfill the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are not any user serviceable parts inside. Do not drop, knock or shake the unit. Rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not expose the unit to any kind of liquids (rain, beverages, paint etc), unless all connectors and the ventilation membrane are sufficiently protected. Do not use or store the unit in dusty or dirty areas, unless all connectors and the ventilation membrane are sufficiently protected. Do not cover or bring mechanical force to the ventilation membrane on the back of the unit. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified conditions.
6643-2230
3
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 55022 +A1, Emission IT equipment
EN 55024 +A1 + A2, Immunity IT equipment
FCC part 15 Class B
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
Safety UL/IEC/EN 60950-1, IT equipment
Marine DNV Standard for Certification no. 2.4
FCC Part 15.105 Notice:
Corrosive environment
Notice:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
… Reorient or relocate the receiving antenna … Increase the separation between the equipment and receiver … Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.
This product has been successfully tested in a corrosion test according to IEC 60068-2-60, method 3. This means that the product meets the requirements to be placed in an environment classified as ISA-S71.04 class G3.
Note! If the product is placed in a corrosive environment, it is important that all un-used connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated pins in connectors.
4
6643-2230
Declaration of Conformity
Org.nr/
th
Westermo Teleindustri AB
Declaration of conformity
The manufacturer
Herewith declares that the product(s)
Type of product Model 1
Industrial Ethernet 5-port Device Server Switch Lynx DSS L*05-S1*
is in conformity with the following EC directive(s).
No Short name
2004/108/EC Electromagnetic Compatibility (EMC) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and
References of standards applied for this EC declaration of conformity.
No Title Issue
EN 61000-6-1 Electromagnetic compatibility – Immunity for residential
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial
EN 61000-6-3 Electromagnetic compatibility – Emission for residential
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial
EN 55024 Information technology equipment - Immunity 1998
EN 55022 Information technology equipment - Emission 2006
EN 50121-4 Railway applications - Electromagnetic compatibility
The last two digits of the year in which the CE marking was affixed: 13
Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden
electronic equipment (RoHS)
environments
environments
environments
environments
Emission and immunity of the signalling and telecommunications apparatus
2007
2005
2007 +A1:2011 2007 +A1:2011
+A1:2001 +A2:2003
+A1:2007 2006
Pierre Öberg Technical Manager
Mars 2013
18
1
The first “*” in the model name can be any alphanumeric character, indicating software version. The second “*” in the
model name can be any alphanumeric characters indicating customer specific models, or blank.
Postadress/Postal address
S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
Tel.
Telefax
Postgiro
Bankgiro Corp. identity number Registered office
6643-2230
5
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
Electrostatic discharge EN 61000-4-2 Enclosure Contact: ±6 kV
Fast transients EN 61000-4-4 Power port ±2 kV
Surge EN 61000-4-5 Power port L-L: ±0.5 kV, 2 Ω, 18 μF
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 60 Hz
Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 – 2700) MHz
Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission EN 55022/
Conducted RF emission EN 55022/
Compass safe distance DNV 2.4 Enclosure Standard compass (5.4°/H deviation) =
Dielectric strength EN 60950-1 Power port to all
FCC Part 15/ DNV 2.4
FCC Part 15/ DNV 2.4
Ethernet Status out/Digital in Serial ports Enclosure
Ethernet L-E: ±2 kV, 2Ω, 0.5 μF Status out/Digital in L-E: ±2 kV, 42 Ω, 0.5 μF
RS-232 L-E: ±2 kV, 2 Ω, 0.5 μF
Ethernet Status out/Digital in Serial ports Earth port Enclosure Class B / DNV bridge
Power port Class B / DNV bridge Ethernet Class B
other ports Ethernet ports to all
other ports RS-232 port to all
other ports
Air: ±8 kV
L-E: ±2 kV, 42 Ω, 0.5 μF L-L: ±1 kV, 42 Ω, 0.5 μF L-E: ±2 kV, 12 Ω, 9 μF L-L: ±1 kV, 12 Ω, 9 μF
L-L: ±1 kV, 42 Ω, 0.5 μF
1000 A/m; 50 Hz
1 kHz sine, 80% AM
15 cm Steering/standby steering/emergency com­pass (18°/H deviation) = 10 cm
1.5 kVrms, 50 Hz, 1 min
6
6643-2230
Loading...