Fibre Optic industrial converter/repeater
for LonWorks® TP/FT-10 point-to-point,
line and redundant ring
www.westermo.com
2
6650-2260
General information
Legal information
The contents of this document are provided “as is”. Except as required by applicable law,
no warranties of any kind, either express or implied, including, but not limited to, the
implied warranties of merchantability and fitness for a particular purpose, are made in
relation to the accuracy and reliability or contents of this document. Westermo reserves
the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or
any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
www.westermo.com
6650-2260
3
Safety
!
!
!
Before installation:
Read this manual completely and gather all information on the unit. Make sure that
you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is
restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary it must be
possible to disconnect manually from the power supply. Ensure compliance to
national installation regulations.
This unit uses convection cooling. To avoid obstructing the airflow around the unit,
follow the spacing recommendations (see Cooling section).
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning! Do not open connected unit. Hazardous voltage may occur within this
unit when connected to power supply.
Class 1 Laser Product
Do not look directly into fibre optical fibre port or any connected fibre although
this unit is designed to meet the Class 1 Laser regulations.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil
the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause
damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not water-
proof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical
part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo dis-
tributor office or Westermo Tech support.
Fibre connectors are supplied with plugs to avoid contamination inside the optical port.
As long as no optical fibre is mounted on the connector, e.g. for storage, service or
transportation, should the plug be applied.
4
6650-2260
Note. Fibre Optic Handling
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If
the fibre will be disconnected from the modem the protective hood on the transmitter/
receiver must be connected. The protective hood must be kept on during transportation.
The fibre optic cable must also be handle the same way.
If this recommendation not will be followed it can jeopardise the warranty.
Cleaning of the optical connectors
In the event of contamination, the optical connectors should be cleaned by the use of
forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
Product disposal
This symbol means that the product shall not be treated as
unsorted municipal waste when disposing of it. It needs to
be handed over to an applicable collection point for recycling electrical and electronic equipment.
6650-2260
By ensuring this product is disposed of correctly, you will
help to reduce hazardous substances and prevent potential
negative consequences to both environment and human
health, which could be caused by inappropriate disposal.
5
Simplified EU declaration of conformity
Hereby, Westermo declares that the equipment is in compliance with applicable EU
directives. The full EU declaration of conformity and other detailed information are
available at the respective product page at www.westermo.com.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
RF field AM modulated IEC 61000-4-3Enclosure10 V/m 80% AM (1 kHz), 80 – 1 000 MHz
Fast transientEN 61000-4-4Signal ports± 1 kV
SurgeSignal ports balanced± 1 kV line to earth, ± 1 kV line to line
RF conductedEN 61000-4-6Signal ports10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency
magnetic field
Pulse Magnetic fieldEN 61000-4-9Enclosure300 A/m, 6.4 / 16 µs pulse
Voltage dips and
interruption
Mains freq. 50 HzEN 61000-4-16 Signal ports100 V 50 Hz line to earth
Mains freq. 50 HzSS 436 15 03Signal ports250 V 50 Hz line to line
Voltage dips
and interruption
Radiated emission CISPR 16-2-3
Conducted emissionCISPR 16-2-1
Dielectric strengthEN 60950Signal port to all other
Environmental
TemperatureEN 60068-2-1
HumidityEN 60068-2-30 Operating5 to 95% relative humidity
AltitudeOperating2 000 m / 70 kPa
Service lifeOperating10 years
VibrationIEC 60068-2-6Operating7.5 mm, 5 – 8 Hz
ShockIEC 60068-2-27 Operating15 g, 11 ms
Packaging
EnclosureUL 94PC / ABSFlammability class V-1
Dimension W x H x D35 x 121 x 119 mm
Weight0.26 kg
Degree of protectionIEC 529EnclosureIP 21
CoolingConvection
MountingHorizontal on 35 mm DIN-rail
EN 61000-4-8Enclosure100 A/m, 50 Hz, 16.7 Hz & 0 Hz
EN 61000-4-11 AC power ports10 & 5 000 ms, interruption
EN 61000-4-29 DC power ports10 & 100 ms, interruption
ANSI C63.4
(FCC part 15)
ANSI C63.4
(FCC part 15b)
EN 60068-2-2
Enclosure air± 8 kV
Power ports± 2 kV
Power ports± 0.5 kV line to earth, ± 0.5 kV line to line
AC power portsClass B
AC power portsClass B
DC power portsClass A
isolated ports
Power port to other
isolated ports
Operating–40 to +70ºC LRW-102PP
Storage & Transport–40 to +70°C
Storage & Transport5 to 95% relative humidity
+20% above & –20% below rated voltage
Class A
1.5 kVrms 50 Hz 1min
2 kVrms 50 Hz 1min
–40 to +60ºC LRW-102
2 g, 8 – 500 Hz
6650-2260
7
Description
The LRW-102 (LRW-102PP) offers an easy way to extend the distance between
LonWorks® 78 kbit/s TP/FT network segments using a fibre optic link.
The LRW-102PP is a fibre optic modem used for point-to-point applications and the
LRW-102 is used for multidrop and redundant ring applications. It acts as a repeater
between the two fibre optic links, and as a converter between fibre optical links and
the LON TP/FT port. The maximum distance of the fibre links depends on selected
transceiver and fibre types.
The LRW-102 (LRW-102PP) is designed for harsh outdoor usage, in industrial, road or
railway installations. The complete transparent conversion to and from the fibre optic
media facilitates the installation procedure by eliminating the need for any additional
network addressing or software configuration.
Convert LON TP/FT-10 interface – optical fibre
… Multidrop, point-to-point alternatively redundant ring communication
via fibre optical network
… Small Form Factor Pluggable (SFP) transceivers
… LC fibre connectors, single or multimode
… LC-2 Multimode LC connectors, 5 km (3.1 miles)
… LC-15 Singlemode LC connectors, 15 km (9.3 miles)
… Bi-di, Multimode LC connectors, 5 km (3.1 miles)
… Bi-di, Singlemode LC connectors, 20 km (12.4 miles)
… Redundant power supply, 2 kVAC galvanic isolated to other ports
… Designed for harsh environments
… Re-timing
… Status port
LonWorks® interface
… 2-positions detachable screw terminal
… Data rate 78 kbit/s
8
6650-2260
Functional description
Converter TP/FT interface – optical fibre
The LRW-102 (LRW-102PP) is a fibre optic converter that converts between
LonWorks® TP/FT, and fibre optical link.
Repeater – optical fibre links
The LRW-102 is a fibre optic repeater that repeats received data from one fibre
link out to the other link. This is useful e.g. for long distance communication, where
electromagnetic interference may occur or when isolation of the electrical network is
needed.
Single or multimode LC fibre connectors
The LRW-102 (LRW-102PP) uses Small Form Factor Pluggable (SFP) transceivers that
are in compliance with Multi-Sourcing Agreement (MSA). A wide range of different fibre
transceivers and connectors can be used.
6650-2260