Westermo LR-11 User Manual

Fibre optic router for TP/FT-10
INSTALLATION MANUAL
6608-2211
www.westermo.se
LR-11
LR-11PP
©
Galvanic Isolation
Transient
Protection
CE
Approved
A
S
R
V
P
W
R
T
D
R
D
B
S
R
V
ASRV
PW
R
TD
RD
BSRV
LONWORKS®and LonTalk®are trademarks of Echelon Corporation registered in United States and other countries.
3
6608-2211
Contents
1 SPECIFICATIONS LR-11/LR-11PP ...................................................................................................................... 4
2 INTRODUCTION
.................................................................................................................................................... 5–6
3 COMMUNICATIONS
......................................................................................................................................... 7–12
3.1 Point to point topology
..................................................................................................................................... 8
3.2 Bus topology
........................................................................................................................................................ 8–9
3.3 Ring topology ................................................................................................................................................... 9–10
3.3.1 Alarm indications ............................................................................................................................. 10–12
4 FIBRE CHANNEL
......................................................................................................................................................... 13
4.1 Introduction
............................................................................................................................................................. 13
4.2 Power budget ......................................................................................................................................................... 14
5 NETWORK INSTALLATION
.............................................................................................................................
14
6 SETTINGS AND CONNECTIONS
................................................................................................................ 15
6.1 Switch settings ....................................................................................................................................................... 15
6.2 Connections ............................................................................................................................................................ 16
6.3 How to connect
................................................................................................................................................... 17
4
6608-2211
1 SPECIFICATIONS LR-11/LR-11PP
GENERAL
FIBRE
Maximum fibre length 25 000 m (between two LR-11 units)
TECHNICAL DATA
Transmission Routing of LonTalk®‚ packets using Echelon RTR-10 router core Interface 1 L
ONWORKS
®
TP/FT, FTT-10A, 5-position screw block
Interface 2 See model specific data Indicators See model specific data Transmission rate L
ONWORKS
®
TP/FT 78 kbit/s
Fibre optic 1 250 kbit/s
Weight, kg 0.3 kg Mounting On 35 mm DIN-rail
POWER SUPPLY ALTERNATIVES
Model description LR-11/LR-11PP HV LR-11/LR-11PP LV Power supply 95–240 V AC ± 10% 12–45 V AC ± 10%
110–240 V DC ± 10% 12–55 V DC ± 10%
Frequency 48–62 Hz / – 48–62 Hz / – Fuse, F2 1 A T Wickmann 1 A T Wickmann Power consumption 40 mA 4 W Transient protection
Power/Line Yes/Yes Yes/Yes
Isolation RMS
Power supply 3 750 V 3 750 V
MODEL SPECIFIC DATA
LR-11 LR-11PP
Interface 2 Fibre optic, Fibre optic,
4 ST-connectors, 2 ST-connectors, See Power budget table on page 14 See table on page 14
Indicators PWR, TD, RD, Tx1, Tx2, PWR, TD, RD, ASRV, BSRV
Rx1, Rx2, ASRV, BSRV
LED INDICATION
LED FUNCTION
PWR Indicates that the unit has power TD Indicates transmitting data on fibre side RD Indicates transmitting data on TP/FT side Rx1 Indicates receiving data on fibre receiver 1 Tx1 Indicates transmitting data on fibre transmitter 1 from TP/FT side Rx2 Indicates receiving data on fibre receiver 2 Tx2 Indicates transmitting data on fibre transmitter 2 from TP/FT side ASRV Indicates status on router side A (TP/FT)
OFF: Side A configured ON: An unrecovered error has been detected on side A Flashing (1 Hz): Side A unconfigured
BSRV Indicates status on router side B (fibre optic)
OFF: Side B configured ON: An unrecovered error has been detected on side B Flashing (1 Hz): Side B unconfigured
5
6608-2211
2 INTRODUCTION
The LR-11 router offers an easy way to extend the distance between LONWORKS
®
78 kbit/s TP/FT network segments using a high-speed 1 250 kbit/s backbone fibre optic network link.
LR-11 is based on Echelon’s RTR-10 standard router core module, this allowing standard configuration and installation with tools such as LonBuilder
®
and LonMaker™.
LR-11 routers can be installed as repeaters, configured routers, or learning routers. The LR-11 is equipped with either one (PP-version) or two pairs of fibre optic receivers
and transmitters. This allows the user to build either point to point-, bus- or ring topology fibre links.
LR-11 PP
Fibre optic channel
LR-11 PP
TP Network
channel 1
TP Network
Channel 2
OPTO LINK MONITOR
CH1CECH2
OPTO LINK MONITOR
CH1CECH2
Fibre optic channel
TP Network
channel 1
LR-11PP LR-11 LR-11PP
TP Network
channel 2
TP Network
channel 3
OPTO LINK MONITOR
CH1CECH2
OPTO LINK MONITOR
CH1CECH2
OPTO LINK MONITOR
CH1CECH2
Figure 2.1 Network topologies
TD RD ASRVBSRVCEPWR
LR-11
Rx1
Rx2
Tx1
Tx2
LONWORKS TP/FT-10 POWER
N1 N2 LN
TD RD ASRVBSRVCEPWR
LR-11
Rx1
Rx2
Tx1
Tx2
LONWORKS TP/FT-10 POWER
N1 N2 LN
TD RD ASRVBSRVCEPWR
LR-11
Rx1
Rx2
Tx1
Tx2
LONWORKS TP/FT-10 POWER
N1 N2 LN
TD RD ASRVBSRVCEPWR
LR-11
Rx1
Rx2
Tx1
Tx2
LONWORKS TP/FT-10 POWER
N1 N2 LN
LR-11
LONWORKS TP/FT-10 POWER
N1 N2 LN
TD RD ASRVBSRVCEPWR
Rx1
Rx2
Tx1
Tx2
6
6608-2211
Figure 2.2 Network topologies
Fibre optic channel
LR-11 Ring master
LR-11 LR-11
TP Network
channel 1
TP Network
channel 1
TP Network
channel 1
TD RD ASRVBSRVCEPWR
OPTO LINK MONITOR
CH1CECH2
OPTO LINK MONITOR
CH1CECH2
OPTO LINK MONITOR
CH1CECH2
In a fibre ring, one of the LR-11 units will be assigned as a ring master and then having the responsibility to stop messages from looping around the ring. The LR-11 has a built­in redundancy scheme that provides for fault tolerances in the fibre rings. There is a maximum transmission distance on the fibre link depending on the available power budget of the LR-11 units and losses due to attenuation in cables, connectors and splice joints. With single mode fibre, distances up to 25 km can be reached.
For the fibre channel communication parameters, the LR-11 is by default set with param­eters used for small network. Depending on the fibre length and the number of devices the communication parameters may be changed to optimize performance. Section 4 will discuss this matter in further detail.
LR-11
Rx1
Rx2
Tx1
Tx2
LONWORKS TP/FT-10 POWER
N1 N2 LN
TD RD ASRVBSRVCEPWR
LR-11
Rx1
Rx2
Tx1
Tx2
LONWORKS TP/FT-10 POWER
N1 N2 LN
TD RD ASRVBSRVCEPWR
LR-11
Rx1
Rx2
Tx1
Tx2
LONWORKS TP/FT-10 POWER
N1 N2 LN
Loading...
+ 14 hidden pages