TECHNICAL SPECIFICATIONS:
Dimensions (Ø x Height): 98 mm x 137 mm Housing: PC/ABS-Blend Lens: PC, transparent Fixing: Base, bracket and tube mounting
Base 975 840 90 must be ordered twice for base mounting - once as socket for beacon and once as base
Connection: Cable entry: Cable diameter 5-7 mm Rated voltage: 24 V DC ± 10 % Input power 24 V AC/DC: 7 W Bulb BA15d: 7 W/24 V Output current capability: 30 V DC/ 100 mA On state resistance of an output: Max. 25 Ω Fuse for 7 W bulb: 500 mA quick action (IEC 60127-3/3) Atmospheric humidity: ≤ 95 % without moisture condensation Response time, normal operation and with fi lament break: in fault cases with safety release: < 300 ms (with short-circuit current ≥ 4 A) Certifi cation: EN ISO 13849-1:2008 category 4,
Peformance Level „e” EN ISO 13849-2:2008 validation Bulb included in assembly.
Screw terminal with wire protection max. 2.5 mm
1 ms to 5 ms
2
Optical Signal Devices
Free-standing Beacons · Permanent Beacons
Tube with base (accessory)
Sizes of Permanent Beacons
ORDER SPECIFICATIONS:
Voltage 24 V DC red 826 110 55 yellow 826 310 55 clear 826 410 55
ACCESSORIES:
Bulb BA15d, 7 W 955 015 35
ADDITIONAL INFORMATION:
Input 24 V
Function
The device is equipped with a lamp monitor which signals the current fl ow of the incandescent lamp back to two electrically isolated, potential-free semiconductor outputs A and B (outputs closed). If the lamp has not been actuated, both outputs are open. In case of a fault and/or a lamp failure at least one output is opened.
TECHNICAL DIAGRAMS:
Monitoring electronics
see page 316
Depending on the safety category, one or two out­puts are to be used for a reliable lamp evaluation. In case of an incandescent filament short-circuit in the lamp, the integrated fuse is tripped. It must be replaced by a new fuse in accordance with the specifi cations after the lamp has been replaced by a lamp of equal wattage.
Signal outputs
See note on page 347
180 g
IP 65
+50°C
0°C
137