826 Monitored Permanent Beacon
Bracket (accessory)
• Built-in monitoring capability
• TÜV approval
• No additional external voltage required
• Two potential-free safety
outputs for connection to
control system
TECHNICAL SPECIFICATIONS:
Dimensions (Ø x Height): 98 mm x 137 mm
Housing: PC/ABS-Blend
Lens: PC, transparent
Fixing: Base, bracket and tube mounting
Base 975 840 90 must be ordered twice for
base mounting - once as socket for beacon
and once as base
Connection:
Cable entry: Cable diameter 5-7 mm
Rated voltage: 24 V DC ± 10 %
Input power 24 V AC/DC: 7 W
Bulb BA15d: 7 W/24 V
Output current capability: 30 V DC/ 100 mA
On state resistance of an output: Max. 25 Ω
Fuse for 7 W bulb: 500 mA quick action (IEC 60127-3/3)
Atmospheric humidity: ≤ 95 % without moisture condensation
Response time,
normal operation and with fi lament break:
in fault cases with safety release: < 300 ms (with short-circuit current ≥ 4 A)
Certifi cation: EN ISO 13849-1:2008 category 4,
Peformance Level „e”
EN ISO 13849-2:2008 validation
Bulb included in assembly.
Screw terminal with wire protection max. 2.5 mm
1 ms to 5 ms
2
Optical Signal Devices
Free-standing Beacons · Permanent Beacons
Tube with base (accessory)
Sizes of Permanent Beacons
ORDER SPECIFICATIONS:
Voltage 24 V DC
red 826 110 55
yellow 826 310 55
clear 826 410 55
ACCESSORIES:
Bulb BA15d, 7 W 955 015 35
ADDITIONAL INFORMATION:
+
Input
24 V
–
Function
The device is equipped with a lamp monitor which
signals the current fl ow of the incandescent lamp back
to two electrically isolated, potential-free semiconductor
outputs A and B (outputs closed). If the lamp has not
been actuated, both outputs are open. In case of
a fault and/or a lamp failure at least one output is
opened.
TECHNICAL DIAGRAMS:
Monitoring
electronics
see page 316
Depending on the safety category, one or two outputs are to be used for a reliable lamp evaluation.
In case of an incandescent filament short-circuit
in the lamp, the integrated fuse is tripped. It must
be replaced by a new fuse in accordance with the
specifi cations after the lamp has been replaced by a
lamp of equal wattage.
Signal
outputs
See note
on page 347
180 g
IP 65
+50°C
0°C
137