Wells MOD-300 User Manual

ELECTRICAL
VOLTS WATTSMODELS SINGLE
MOD-300
MOD-300 MOD-300T MOD-300T
MOD-300EUT
ALL MODELS WITH A 'D' OR 'DM'
240 208
3600 3720
SUFFIX HAVE THE SAME ELECTRICAL
CUTOUT DETAILS
4 1/8 (105)
42 1/2 (1080)
AMPS PER LINE 3 PHASE
L1 L2 L3
7.5
8.7
10.3
11.9 11.9
22 1/2
(572)
7.5
8.7
10.3
3 1/8
(79)
16 7/8
(429)
FRONT PANEL CUTOUTTOP CUTOUT
AMPS
PHASE
13.07.5208 2700
SPECIFICATIONS AS THE STANDARD
FIELD WIRING GAUGE
3 PHASE 12 AWB Cu 12 AWB Cu 12 AWB Cu 12 AWB Cu
5
(127)
1 PHASE 12 AWB Cu 12 AWB Cu15.08.7 10 AWB Cu17.910.3 10 AWB Cu20.611.9240 4950
2
MOD-300 OR MOD-300T MODELS.
INSTALLATION INSTRUCTIONS
BUILT-IN MODULAR WARMERS
TEMP.
RATING
75°C 75°C 75°C 75°C 90°C2.5mm20.64950220-240
MOD 300 SERIES (T, TD, TDM)
PRODUCT DIMENSIONS
14
(356)
7 3/4 (197)
INCHES
(MM)
23 5/8
(600)
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
BACK SIDE BOTTOM FRONT
1 1 6 3/4 4 1/8
(25) (25) (171) (105)
INSTALLATION INSTRUCTIONS
NOTE: MOD-300 UNITS ARE SHIPPED THREE PHASE AND ARE FIELD CONVERTIBLE TO SINGLE PHASE. THE DRAIN MANIFOLD WITH 1" INTERNAL NPT VALVE IS SUPPLIED FOR DM AND TDM MODELS ONLY.
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. Required Installation Clearances: Wooden and Metal Installation: DO NOT install closer than 4 1/8 inches to front wall, 1 inch to back and side walls, and 6 3/4 inches to a surface below the unit. If the control box is located below the unit, the front clearance may be 1 inch.
2. Unit shall be accessible for servicing from the bottom.
3. If storage is to be used underneath the unit, it is recommended that a baffle be placed 8 1/2 inches below the unit to avoid contact with elevated temperatures.
TO FABRICATE:
1. Layout "cutout" dimensions on countertop and front apron.
2. Layout and fabricate control panel holes in counter apron using control box as a template.
3. Cut out holes.
4. Unit shall be accessible for servicing from the bottom.
TO INSTALL: IMPORTANT - DO NOT disconnect "lead wires" from the Master Control Panel when making installation.
1. Tilt and pass Control Panel and electrical box through countertop cutout, then through apron cutout. Lower modular section into countertop cutout and position. RECOMMENDATION: Before final seating of modular section to countertop, apply a bead of silicone adhesive/sealant to underside of gray gasket material supplied on mounting flange.
2. From underneath, insert screwdriver into "slots" in Wellslok frame and twist "ears" outward (clockwise) as required to secure flange tightly to countertop.
3. Mount the Control Box to the apron cutout as shown in the drawing.
43 1/2
(1105)
18
(457)
2 1/4
(57)
6 1/4 (159)
1/2 INCH INTERNAL N.P.T. 'D' MODELS ONLY
9 3/4 (248)
4. Mount Control Panel onto electrical box using screws supplied.
TO PLUMB:
1. A drain manifold complete with valve is supplied on all Model "DM" and "TDM" units. Location of valve handle is at the discretion of the fabricator. Install and tighten pipe plug in one end of the manifold.
2. Warmers with 'D' suffix are supplied with individual 1/2'' female N.P.T. drains.
3. Connect 1'' drain connection to suitable drain line. TO WIRE:
1. Final connection is accomplished by bringing proper power supply leads (see 'wiring requirements' label) through conduit knockout to terminal block supplied within the Master Control Panel. Check nameplates for voltage and phase.
2. Do not connect to a circuit operating at more than 150 volts to ground.
NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND
ELECTRICAL CODES.
WARMER FLANGE
GASKET
MASTER CONTROL PANEL
SCREWDRIVER
COUNTERTOP
WELLSLOK
IMPORTANT: MOUNT APPLIANCE SO THAT BOTH THE CONTROL PANEL AND DRAIN MANIFOLD ARE LOCATED TO THE FRONT OF THE FIXTURE.
WELLS/BLOOMFIELD * VERDI, NV
37099-3 REV (A)
1 3/4
(44)