ELECTRICAL
VOLTS WATTSMODELS SINGLE
MOD-300
MOD-300
MOD-300T
MOD-300T
MOD-300EUT
ALL MODELS WITH A 'D' OR 'DM'
240
208
3600
3720
SUFFIX HAVE THE SAME ELECTRICAL
CUTOUT DETAILS
4 1/8
(105)
42 1/2
(1080)
AMPS PER LINE 3 PHASE
L1 L2 L3
7.5
8.7
10.3
11.9 11.9
22 1/2
(572)
7.5
8.7
10.3
3 1/8
(79)
16 7/8
(429)
FRONT PANEL CUTOUTTOP CUTOUT
AMPS
PHASE
13.07.5208 2700
SPECIFICATIONS AS THE STANDARD
FIELD WIRING GAUGE
3 PHASE
12 AWB Cu
12 AWB Cu
12 AWB Cu
12 AWB Cu
5
(127)
1 PHASE
12 AWB Cu
12 AWB Cu15.08.7
10 AWB Cu17.910.3
10 AWB Cu20.611.9240 4950
2
MOD-300 OR MOD-300T MODELS.
INSTALLATION INSTRUCTIONS
BUILT-IN MODULAR WARMERS
TEMP.
RATING
75°C
75°C
75°C
75°C
90°C2.5mm20.64950220-240
MOD 300 SERIES (T, TD, TDM)
PRODUCT DIMENSIONS
14
(356)
7 3/4
(197)
INCHES
(MM)
23 5/8
(600)
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
BACK SIDE BOTTOM FRONT
1 1 6 3/4 4 1/8
(25) (25) (171) (105)
INSTALLATION INSTRUCTIONS
NOTE: MOD-300 UNITS ARE SHIPPED THREE PHASE AND
ARE FIELD CONVERTIBLE TO SINGLE PHASE. THE DRAIN
MANIFOLD WITH 1" INTERNAL NPT VALVE IS SUPPLIED
FOR DM AND TDM MODELS ONLY.
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. Required Installation Clearances:
Wooden and Metal Installation: DO NOT install closer than
4 1/8 inches to front wall, 1 inch to back and side walls,
and 6 3/4 inches to a surface below the unit. If the
control box is located below the unit, the front clearance
may be 1 inch.
2. Unit shall be accessible for servicing from the bottom.
3. If storage is to be used underneath the unit, it is
recommended that a baffle be placed 8 1/2 inches below
the unit to avoid contact with elevated temperatures.
TO FABRICATE:
1. Layout "cutout" dimensions on countertop and front
apron.
2. Layout and fabricate control panel holes in counter
apron using control box as a template.
3. Cut out holes.
4. Unit shall be accessible for servicing from the bottom.
TO INSTALL:
IMPORTANT - DO NOT disconnect "lead wires" from the
Master Control Panel when making installation.
1. Tilt and pass Control Panel and electrical box through
countertop cutout, then through apron cutout. Lower
modular section into countertop cutout and position.
RECOMMENDATION: Before final seating of modular section
to countertop, apply a bead of silicone adhesive/sealant
to underside of gray gasket material supplied on mounting
flange.
2. From underneath, insert screwdriver into "slots" in
Wellslok frame and twist "ears" outward (clockwise) as
required to secure flange tightly to countertop.
3. Mount the Control Box to the apron cutout as shown in
the drawing.
43 1/2
(1105)
18
(457)
2 1/4
(57)
6 1/4
(159)
1/2 INCH
INTERNAL N.P.T.
'D' MODELS ONLY
9 3/4
(248)
4. Mount Control Panel onto electrical box using screws
supplied.
TO PLUMB:
1. A drain manifold complete with valve is supplied on all
Model "DM" and "TDM" units. Location of valve handle is at the
discretion of the fabricator. Install and tighten pipe plug in
one end of the manifold.
2. Warmers with 'D' suffix are supplied with individual 1/2''
female N.P.T. drains.
3. Connect 1'' drain connection to suitable drain line.
TO WIRE:
1. Final connection is accomplished by bringing proper power
supply leads (see 'wiring requirements' label) through conduit
knockout to terminal block supplied within the
Master Control Panel. Check nameplates for voltage and phase.
2. Do not connect to a circuit operating at more than 150 volts
to ground.
NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND
ELECTRICAL CODES.
WARMER FLANGE
GASKET
MASTER
CONTROL
PANEL
SCREWDRIVER
COUNTERTOP
WELLSLOK
IMPORTANT:
MOUNT APPLIANCE SO THAT BOTH
THE CONTROL PANEL AND DRAIN
MANIFOLD ARE LOCATED TO THE
FRONT OF THE FIXTURE.
WELLS/BLOOMFIELD * VERDI, NV
37099-3 REV (A)
1 3/4
(44)