www.cooperhandtools.com/europe
WHA 3000P Hot Air Station
Operating Instructions
Version 2.0
Page
1
COOPER TOOLS GmbH
Carl-Benz-Str.
Germany Tel: 07143-580-0, Fax: 07143-580-108
2 74354 Besigheim 3

www.cooperhandtools.com/europe
Table of contents
1. Description
Technical data
2. Placing in operation
2.1
Manual operating mode
2.2
Automatic operating
2.3
Setting temperature profile
2.4
Starting program
2.5
Control of the vacuum function
2.6
Saving and loading temperature-time profiles
3. External sensor
3.1 External sensor with measuring function "MEASURE MODE
(factory setting)
3.2 Teach In Mode procedure
3.3 External sensor with control function "CONTROL MODE
4. Lock Mode
5
5
6
mode
8
7
8
9
Page
6
9
10
10
10
10
11
5. Switching Temperature Conversion
6. RS232 Interface
7. Work Instructions
8. Maintenance
9. Error Messages
10.
Accessories
11.
Items Supplied
12.
Hot Air Nozzles
13. Quick Reference
11
11
11
11
12
12
12
13
14
Page
2
COOPER TOOLS GmbH
Carl-Benz-Str.
Germany Tel: 07143-580-0, Fax: 07143-580-108
2 74354 Besigheim 3

www.cooperhandtools.com/europe
Operating instructions WHA 3000P
Front view WHA3000P
1
LCD Display
2
"UP" Control Key
3
"DOWN" Control Key
4
Mains Switch
5
"TIME"/"PREHEAT" Control Key (time setting auto. mode / pre-heating temperature)
6
"AIR" Control Key (air flow rate)
7
"TEMP" Control Key (hot air temperature)
8
LED
Indicator
9
LED Indicator, START/STOP
10 "START/STOP" Control Key
11
"VAC" Control Key (activate Vacuum)
12 "AUTO"
13 LED Indicators, Auto-Man operating mode
14 Conne
ction for External Sensor Type K
"MAN" Control Key (changeover Automatic
, Vacuum
Manual operating mode)
Page
3
COOPER TOOLS GmbH
Carl-Benz-Str.
Germany Tel: 07143-580-0, Fax: 07143-580-108
2 74354 Besigheim 3

www.cooperhandtools.com/europe
Rear view WHA3000P
15 Vacuum Pump Filter
16 Hand-piece Connecting Hose
17 Stand Switch Connection
18 Mains Connection
19 Mains Fuse
20 Connection for Manual Control Console; Foot Switch
21 PC Interface, RS232
22 Connection for WHP3000 (bottom heater), RS232 Interface
Page
4
COOPER TOOLS GmbH
Carl-Benz-Str.
Germany Tel: 07143-580-0, Fax: 07143-580-108
2 74354 Besigheim 3

www.cooperhandtools.com/europe
We thank you for the confidence you have shown by purchasing the Weller WHA3000P Hot Air
Station. During manufacturing, the strictest quality requirements are applied; these assure the
correct function of the device and make it possible to obtain optimal soldering results.
Prior to placing the device in operation, please carefully read these operating instructions and the
safety instructions enclosed.
The manufacturer accepts no liability for usage other than that described in the operating
instructions or for
The WELLER WHA3000P Hot Air Station complies with the EU declaration of conformity as per the
essential safety requirements in the directives 89/336/EEC and 73/23/EEC
1. Description
The WHA3000P Hot Air Station is suitable for difficult repairs on circuit boards with FINEPITCH
components.
technically advanced application solutions. A comprehensive range of accessories adds to the
possible uses of this repair workstation.
The hot air temperature at the hand-piece can be adj
999°F).
of 5 l/min 50 l/min.
The vacuum necessary for lifting the component is integrated into the nozzle system and can be
activated to suit the operating mode chosen.
A The "Manual operating mode (MAN) can be used for manual work at the hot air temperature
B The "Automatic operating mode (AUTO) establishes a program with a 3-step time/
Warning!
unauthorized
If
the safety instructions are not observed, there is a risk of injury.
modifications
A thorough design concept combines maximum process safety with ease of use and
usted over the range of 50°C
The air flow rate is generated via an internal turbine and can be adjusted between the range
Hot air temperature and air flow rate are digitally controlled.
Two operating modes are provided:
and air flow rate set. Hot air and vacuum can be activated using the foot switch, manual
remote control console or directly on the control Panel.
temperature profile, and can be used in conjunction with the WHP3000 Pre-Heat Plate
available as an accessory.
550°C (150°F
The parameters for hot air temperature, air flow rate, temperature of the optional WHP3000 PreHeat Plate and vacuum function can be adjusted separately and can be saved as a Rework
for the specific application.
The repair station can also be complemented with the optional matched WBH3000S Circuit Board
Holder for X-Y alignment and a stand with Z-axis guide for the hot air hand-piece.
Technical data
Dimensions (W X L X H):
Mains voltage:
Power consumption:
Air flow rate:
Temperature range:
Accuracy:
Vacuum:
Mains fuse:
Protection class:
-
240 (9.44) X 270 (10.63) X 170 (6.69) mm (inch)
230 V (120 V) AC
600 W
5
50°C
+/- 30°C (+/- 86°F)
230 V / T6.3A (120 V / T8 A)
1 (Control Unit and Hand-Piece are hard grounded)
50 l/min
0.6 bar
550°C (150°F
Page
999°F)
5
COOPER TOOLS GmbH
Carl-Benz-Str.
Germany Tel: 07143-580-0, Fax: 07143-580-108
2 74354 Besigheim 3
Profile