Welch Allyn 73210 User Manual

Rectal Light Handle
REF 73210
6V Power Supply
REF 73305, 73322, 73324, 73326
Table of Contents
Symbol Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . 2
Instructions for Use . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
REF 73210 Rectal Light Handle . . . . . . . . . . . . . . . . . . . . .4
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Preventative Maintenance . . . . . . . . . . . . . . . . . . . . . . . . .7
Lamp Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Trouble Shooting Guide . . . . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting Guide - Qualified Personnel Only . . . 13
Warranty and Service . . . . . . . . . . . . . . . . . . . . . . . . . 14
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Welch Allyn Service Centers . . . . . . . . . . . . . . . . . . . . . .16
Thank you for purchasing the Welch Allyn REF 73210 Rectal Light Handle and/or the REF 73305, 73322, 73327, 73326 power supply. Please review this manual prior to using this system.
Only properly trained physicians for endoscopic type examinates should use the 73210 Rectal Light Handle and its appropriate Power Supply when coupled with the Welch Allyn devices listed in the table on page 6.
The 73210 Rectal Light Handle is designed for connection only with the power source and appropriate country voltage and outlet style listed within this manual. No other use of these products is intended or advised. Please follow the guidelines set forth in this manual for proper connection and use of the Rectal Light Handle.
Classification
Class II, Type BF Applied Part Ordinary Equipment
Intermittent Operation
Symbol Descriptions
Attention, Warning, Caution: See instructions for use.
Caution, high temperatures - - -
Caution, high intensity light Alternating Current
Double Insulation IPXØ
Type BF Applied Part
Direct Current
Not protected from the ingress of water.
1
Warnings and Cautions
WARNING: To avoid eye injury, do not look directly into the lamp beam.
WARNING: Lamp is harmful to skin if touched when hot. Allow lamp to cool for 5 minutes before replacing.
WARNING: Rectal Light Handle and/or Power Supply is not suitable for use in the presence of a flammable anesthetic mixture with air or oxygen or nitrous oxide. An explosion may result.
WARNING: Lamp generates heat and should remain off until just prior to and immediately after use. Do not place Rectal Light Handle onto a flammable surface if lamp is illuminated.
WARNING: Disconnect power supply from outlet prior to any maintenance.
WARNING: Only use the 6V power supplies described within this manual with the the 73410 Rectal Light Handle. Failure to observe this warning may cause damage to the power supply and/or non-approved device
CAUTION: U.S. Federal Law restricts this device to sale by or on the order of a physician.
CAUTION: Rectal Light Handle Illumination is intense.
CAUTION: This endoscopic accessory is for use with the Welch Allyn devices listed in the table on page 6 only. Do not use the illuminator for any other use.
CAUTION: Use only the cleaning methods described in this manual.
CAUTION: There are no user-serviceable parts inside the device except the lamp. Contact the authorized Service Center listed on page 16 for service related issues.
The 73210 Rectal Light Handle is designed for connection only with the power source and appropriate country voltage and outlet style listed within this manual No other use of these products is intended or advised.
2
Instructions for Use
The Rectal Light Handle’s power supply (REF 73305, 73322, 73324, 73326) pro­vides power from an appropriate wall outlet to the Rectal Light Handle (REF
73210) which houses the lamp (REF 07800). The Rectal Light Handle and its appropriate power supply provide an illumination system that is intended for use with Welch Allyn devices and/or accessories (see table on page 6).
REF 73305, 73322, 73324, 73326 (Power Supplies)
Verify that the power supply will connect to the appropriate outlet and that the power supplied to the outlet is within the range specified in the table provided.
REF
73305 120V 60 Hz 71 110 - 130
73322 230V 50 Hz 30 210 - 230
73324 240V 50 Hz 27 230 - 250
73326 234V 50 Hz 27 230 - 250
Nom. Input
Voltage
Input Current at
Nom. Input
Vol tag e (m A)
Input Voltage
Range (V.)
Outlet Type
ABC D
USA
NEMA 1-15P
Insert the Power Supply into the receptacle of an appropriate voltage and plug configuration.
Once properly connected, the green LED located on the power supply housing will illuminate indicating power is present to the power supply cord.
EUROPE
CEE 7/16
UNITED KINGDOM
BS 1363
Plug Style
A
B
C
D
AUSTRALIA
NEW ZEALAND
AS 3112
3
REF 73210 Rectal Light Handle
Attach the 73210 Rectal Light Handle to the appropriate device selected from the table on page 6.
REF 38/39 Series
REF 32 Series
REF 37 Series
REF 53130
REF 53110
REF 38700
REF 36019
REF 73210
REF 73305 (SHOWN) REF 73322 REF 73324 REF 73326