Thank you for purchasing a WEG motor. Our products are developed with the highest standards of
quality and efficiency which ensures outstanding performance.
Since electric motors play a major role in the comfort and well-being of mankind, it must be identified
and treated as a driving machine with characteristics that involve specific care, such as proper
storage, installation and maintenance
All efforts have been made to ensure that the information contained in this manual is faithful to the
configurations and applications of the motor.
Therefore, we recommend that you read this manual carefully before proceeding with the installation,
operation or maintenance of the motor in order to ensure safe and reliable operation of your
equipment and facility. If you need any further information, please contact WEG.
Always keep this manual close to the motor, so that it can be consulted whenever necessary.
ATTENTION
1. It is imperative to follow the procedures contained in this manual for the warranty to be valid;
2. The motor installation, operation and maintenance procedures must be performed only by qualified
personnel.
NOTES
1. The total or partial reproduction of information supplied in this manual is authorized, provided that
reference is made to its source. If this manual is lost, an electronic PDF file is available at www.weg.net
or another printed copy may be requested.
3.2.1 Motor positioning ................................................................................................................................ 15
4.4.2 General considerations ....................................................................................................................... 22
4.4.3 Measurement on the stator windings................................................................................................... 22
4.4.4 Additional Information ......................................................................................................................... 22
4.4.5 Polarization Index ................................................................................................................................ 22
4.4.6 Conversion of the measured values ..................................................................................................... 23
4.5.1.1 Temperature limits for the windings ..................................................................................... 24
11371757 Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical l 7
www.weg.net
4.5.1.2 Alarm and trip temperatures ............................................................................................... 24
4.5.1.3 Temperature and ohmic resistance of the PT100 thermoresistance .................................... 25
4.5.1.4 Space heater ...................................................................................................................... 25
4.5.2 Water leak sensor ...............................................................................................................................25
4.8.1 Base ...................................................................................................................................................29
4.8.2 Base loads ..........................................................................................................................................29
4.8.3 Motor mounting ..................................................................................................................................29
4.8.3.1 Motor with solid shaft and flange ........................................................................................ 29
4.8.3.2 Motor with hollow shaft and flange ...................................................................................... 29
4.8.4 Anchor plate set ..................................................................................................................................29
4.8.5 Natural frequency of the base ..............................................................................................................30
6.3.1 General ...............................................................................................................................................35
13 SERVICE NETWORK ........................................................................................ 55
11371757 Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical l 9
www.weg.net
14 WARRANTY TERM ............................................................................................ 56
10 l Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical 11371757
www.weg.net
1 INTRODUCTION
This manual contains information regarding low and high-voltage, three-phase induction motors.
Motors with special features can be supplied with specific documents (drawings, connection diagram, characteristic curves
etc.). Those documents, together with this manual, must be thoroughly evaluated before proceeding with the installation,
operation or maintenance of the motor.
In order to use a frequency inverter, it is mandatory to follow the instructions contained in the specific technical
documentation of the motor and in the manual of the frequency inverter.
If any additional explanation about motors with major special features is necessary, consult WEG. All procedures and
standards contained in this manual must be observed in order to ensure proper operation of the motor and the safety of the
personnel involved in its operation. Following these procedures is also important to ensure the validity of the motor warranty.
Thus, we recommend the careful reading of this manual before the installation and operation of the motor. If any further
information is still necessary, consult WEG.
1.1 SAFETY WARNINGS IN THE MANUAL
In this manual, the following safety warnings are used:
DANGER
Failure to observe the procedures recommend in this warning may result in death, serious injuries and
extensive equipment damage.
ATTENTION
Failure to observe the procedures recommend in this warning may result in equipment damage.
NOTE
This provides important information for correct understanding and proper operation of the product.
11371757 Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical l 11
www.weg.net
Thus, the operation with open terminal boxes,
ATTENTION
ATTENTION
2 GENERAL INSTRUCTIONS
All the personnel involved with the assembly, operation or maintenance of electrical installations must be permanently
informed and updated on the standards and safety instructions that guide the job and are advised to strictly comply with
them. Before beginning any job, the person in charge must make sure that all points have been duly observed and warn the
respective personnel about the danger inherent to the task to be performed.
Improper application, inadequate handled or maintenance of the motor, may cause serious injuries and/or material damages.
Therefore, it is highly recommended that these services be always performed by qualified personnel.
2.1 QUALIFIED PERSONNEL
The term qualified personnel means those who, because
of their training, experience, education level, and
knowledge of the applicable standards, specifications,
accident prevention, safety standards and operating
conditions, have been authorized by the persons in charge
to execute the necessary tasks, and who are able to
recognize and avoid any possible danger.
Such qualified personnel must also know and be able to
provide first aid procedures if necessary.
The entire start-up, maintenance and repair tasks must
only be performed by qualified personnel.
2.2 SAFETY INSTRUCTIONS
DANGER
During normal operation of this equipment, a
hazard associated with energized or rotating
components with high voltage or elevated
temperatures exists.
unprotected couplings, improper handling, or
failure to comply with the operating
standards, may cause severe personal
injuries and material damages.
When devices and equipment are used
outside the industrial environment, the user
must ensure the safety of the equipment by
adopting proper protection and safety
measures during installation (for example,
keep people away, avoid contact of children,
etc.).
Those responsible for the safety of the installation must
ensure that:
Only qualified personnel install and operate the
equipment;
They have this manual and all other documents
supplied with the motor at hand, as well as that they
perform the tasks in strict compliance with the service
instructions, relevant standards and specific product
documentation;
Qualified personnel must also observe:
All the technical data regarding the allowed applications
(operating conditions, connections and installation
environment), included in the catalog, in the purchase
order documents, in the operating instructions, in
manuals and all other documentation;
The specific regulations and conditions for the loca
l
installation;
The use of suitable tools and equipment for handling
and transportation;
That the protective devices of the individual
components are removed shortly before installation.
Individual parts must be stored in vibration-free
environments, avoiding falls and ensuring their protection
against aggressive agents and/or that they do not
jeopardize people.
2.3 STANDARDS
The motors are specified, designed, manufactured and
tested according to the standards described in Table 2.1.
The applicable standards are specified in the commercial
contract, which may indicate other national or international
standards, depending on the application or installation
location.
Specification IEC60034-1 / NBR 17094
Dimensions IEC60072 / NBR 15623 MG1-4,11
Tests IEC60034-2 / NBR 5383 MG1-12
Levels of
protection
Cooling IEC60034-6 / NBR IEC 60034-6 MG1-6
Mounting IEC60034-7 / NBR IEC 60034-7 MG1-4
Noise IEC60034-9 / NBR IEC 60034-9 MG1-9
Mechanical
Vibration
Terminal
marking
Mechanical
Tolerances
Balancing ISO1940 MG1-7
Table 2.1: Applicable standards
IEC60034-5 / NBR IEC 60034-5 MG1-5
IEC60034-14 / NBR IEC 60034-14 MG1-7
IEC / NBR NEMA
IEC60034-8 / NBR 15367 MG1-2
ISO286 / NBR6158 MG1-4
MG1-
1,10,20
Failure to comply with installation and safety
standards may void the product warranty.
Firefighting equipment and first aid notices
must be available in visible and easily
accessible locations at the work site.
12 l Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical 11371757
2.4 ENVIRONMENTAL CONDITIONS
ATTENTION
°C, antifreeze
The motor was designed according to the specific
environmental conditions (temperature and altitude) of
your application, and are described on the nameplate and
in the datasheet of the motor.
For the use of water-cooled motors in
ambient temperatures below +5
additives must be added to the water.
2.5 OPERATING CONDITIONS
In order for the product warranty to be valid, the motor
must be operated according to nominal data indicated on
its nameplate, observing all applicable standards and
information contained in this manual.
www.weg.net
2.6 VOLTAGE AND FREQUENCY
It is very important to ensure a proper power supply for
the motor. The conductors and the entire protection
system must ensure the quality of the power supply at the
motor terminals within the limits, in accordance with the
IEC60034-1 standard:
Voltage: may vary within a range of ±10% of the rated
value;
Frequency: may vary within a range of -5% to +3% of
the rated value.
Figure 2.1: Voltage and frequency variation limits
Figure 2.1 legend:
1. Voltage
2. Zone A
3. Frequency
4. Zone B (outside zone A)
5. Voltage with rated characteristics
The motor must be able to perform its main function
continuously in Zone A, but it may not fully meet its
performance characteristics at rated voltage and
frequency (refer to the point with rated characteristics in
Figure 2.1), when it may present some deviations. The
temperature rises may be above those at rated voltage
and frequency.
The motor must be able to perform its main function in
Zone B, but regarding the performance characteristics at
rated voltage and frequency, it may present deviations
greater than those of Zone A. The temperature rises may
be higher than those observed at rated voltage and
frequency, and they will most likely be higher than those in
Zone A.
Prolonged operation in the periphery of Zone B is not
recommended.
11371757 Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical l 13
www.weg.net
ATTENTION
Any damage must be photographed,
documented and reported immediately to the
ATTENTION
Parts supplied in additional packages must be
lifting
ATTENTION
or transport the motor, the
Lifting equipment and devices must be able
3 RECEIVING, HANDLING AND STORAGE
3.1 RECEIVING
All motors were tested and are in perfect operating
conditions. The machined surfaces are protected against
corrosion. The package must be inspected upon receipt
for occasional damages during transportation.
3.2 HANDLING
Vertical motors must be handled as shown in Figure
3.1;
Use the motor top lifting lugs for vertical movements, so
that the lifting chains or cables are also in the vertical
position, avoiding too much stress on the lifting lugs.
carrier, the insurer and WEG. The noncommunication of this damage will void the
warranty.
checked upon receipt.
When lifting the package (or container), the proper
hoisting points, the weight indicated on the package or
on the nameplate and the operating capacity and
conditions of the hoisting equipment must be observed;
Motors packed in wooden crates must always be lifted
by their own lifting lugs or by a proper forklift; they must
never be lifted by the package;
The package can never be overturned. Place it on the
floor carefully (without impact) in order to avoid damage
to the bearing;
Do not remove the grease for protection against
corrosion from the shaft end, or the closing plugs
present in the terminal box holes. These protections
must remain in place until the moment of the final
assembly.
A complete visual inspection of the motor must be
arried out after removing the package;
c
The shaft locking system must be removed just before
the installation and stored to be used in future
transportation of the motor.
Figure 3.1: Motor handling
NOTES
Observe the indicated weight. Do not lift
the motor causing jolts or put it down
abruptly on the floor, because this can
cause damage to the bearings;
In order to lift the motor, use only the
lugs provided for that purpose. If
necessary, use a crossbeam to protect
parts of the motor.
The lifting lugs on the heat exchanger, end
shields, bearings, radiator, terminal box,
etc. are designed to handle these
components only separately;
Never use the shaft to lift the motor;
The frame lifting lugs are intended to lift
only the motor. Never use them to lift the
motor-driven machine set.
14 l Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical 11371757
In order to move
shaft must be locked with the locking
device supplied with the motor.
to withstand the motor weight.
3.2.1 Motor positioning
ATTENTIO
recommendations may cause damage to the
ATTENTION
Any damage to the paint
ATTENTION
To assure that the motor warranty be valid, it
Vertical motors are supplied with lifting lugs at the drive
end DE and non-drive end NDE.
Some motors are transported in the horizontal position
and need to be moved to the original position. Figure 3.2
shows how to move motors from the horizontal position to
the vertical position and vice versa.
Figure 3.2: Motor positioning
In order to position vertical motors, proceed according to
the following recommendations:
1. Lift the motor using the side lifting lugs and two
hoists;
2. Lower the motor drive end (DE) and lift the non-drive
end (NDE) at the same time until balance is reached;
3. Loosen the DE cables and turn the motor 180º in
order to enable the connection of these cables to the
other lifting lugs of the NDE;
4. Connect the loose cables to the NDE lifting lugs and
lift them until the motor reaches the vertical position.
Failure to comply with these
equipment, personal injuries or both.
N
3.3 STORAGE
If the Motor is not installed immediately after reception, it
must remain inside the package and stored in a location
protected against moisture, vapors, sudden changes in
temperature, rodents and insects.
The motor must be stored in vibration-free locations in
order to avoid bearing damage.
www.weg.net
Space heaters must remain powered during
storage in order to avoid moisture
condensation inside the motor.
protection of the machined parts must be
repaired.
or corrosion
3.3.1 Outdoor storage
The motor must be stored in a dry location, free of
flooding and vibrations.
Repair any damages on the package before storing the
motor, which is needed to ensure proper storage
conditions.
Place the motor on platforms or foundations that ensure
protection against humidity from the ground and prevent it
from sinking into the soil. Free air circulation underneath
the motor must be assured.
The cover used to protect the motor against the bad
weather must not be in contact with its surfaces. In order
to ensure free air circulation between the motor and such
covers, place wooden blocks as spacers.
3.3.2 Extended storage
When the motor is stored for a long period of time (two
months or more) before start-up, it is exposed to
external agents, such as temperature variations,
moisture, aggressive agents, etc.
The empty spaces inside the motor – such as rolling
bearings, terminal boxes, and windings – are exposed to
humidity, which can cause condensation, and,
depending on the degree of air contamination,
aggressive substances may also penetrate these empty
spaces.
Consequently, after long periods of storage, the winding
insulation resistance may drop below the acceptable
values, internal components, such as rolling bearings,
may oxidize, and the lubricant power of the lubricant
agent in the bearings may be adversely affected.
All of these influences increase the risk of damages
before starting the motor.
is necessary to make sure that all preventive
measures described in this manual, such as
constructive aspects, maintenance,
packaging, storage, and periodical
inspections, are followed and recorded.
The extended storage instructions are valid for motors
that remain stored for long periods (two months or more)
before start-up or motors already installed that are in a
prolonged stoppage, considering the same period.
3.3.2.1 Storage location
In order to ensure the best storage conditions for the
motor during long periods, the chosen location must
strictly meet the criteria described in sections 1.1.1.1.1
and 3.3.2.1.2.
11371757 Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical l 15
www.weg.net
ATTENTION
ATTENTION
3.3.2.1.1 Indoor storage
In order to ensure better storage conditions for the motor,
the storage site must comply strictly with the criteria
described below:
The storage site must be closed, covered, dry, free of
air contaminants (moisture, vapor, dust, particles and
aggressive fumes) and free of flooding;
The site should be protected against sudden
temperature variations, humidity, rodents and insects;
Vibration-free location, to avoid damaging to the motor
bearings;
The floor must be of leveled concrete with resistant
structure to support the motor weight;
Must have system to fire detection and extinguishing;
Be provided with electricity for supplying the space
eaters with power failure detection system;
h
Exclusive site to store electrical machines (do not mix
with other equipment and/or products that could
prejudice the correct motor storage);
Site with facilities of cargo handling services, suitable to
allow the motor handling and removal;
There must be no gas present, such as chlorine, sulfur
dioxide or acids;
The site must have ventilation system with air filter;
Ambient temperature between 5°C and 50°C, and
should not present sudden temperature variation;
Relative air humidity <50%;
Must have prevention against dirt and dust deposition;
The motor should be stored on a suitable metal base
that prevents the absorption of moisture from the floor.
If any of these requirements is not met in the storage site,
WEG suggests that additional protections be added to the
motor package during the storage period, as follows:
A closed wooden crate or the like with an electrical
installation that allows the energization of the space
heaters;
If there is a risk of infestation and fungus formation, the
package must be protected in the storage place by
spraying it or painting it with appropriate chemicals;
The package preparation must be prepared carefully b
an experienced person.
y
3.3.2.1.2 Outdoor storage
Outdoor storage of the motor is not
recommended.
In case outdoor storage is unavoidable, the motor must be
packed in specific packaging for such conditions, as
follows:
For outdoor storage (exposed to the weather), besides
the packaging recommended for indoor storage, the
package must be covered with protection against dust,
moisture and other odd materials, using resistant
canvas or plastic.
The package must be placed on platforms or
foundations that ensure protection against dirt and
moisture and prevent it from sinking into the soil;
After the package is covered, a shelter must be erec
to protect it against direct rain, snow and excessive sun
heat.
ted
In case the motor remains stored for long
periods (two months or more), it is
recommended to inspect it regularly as
specified in the section
during storage
Maintenance plan
of this manual.
3.3.2.2 Separate parts
If parts are supplied separately (terminal boxes, heat
exchanger, end shields, etc.), these parts must be
mounted on motor to store it;
Spare parts must be stored in an adequate place, as
specified in sections
manual.
The relative humidity inside the package must not
exceed 50%.
Rolling bearings must not be subject to shocks, falls or
storage with vibration or humidity, which can cause
marks on the internal tracks or on the balls, reducing
their useful life.
1.1.1.1.1
and 3.3.2.1.2 of this
3.3.3 Preservation during the storage
3.3.3.1 Space heater
Space heaters must remain powered during storage to
avoid moisture condensation inside the motor and ensure
that the winding insulation resistance remains within
acceptable levels.
The space heaters drive circuit must be unique and the
voltage and current of this circuit must be measured and
recorded monthly.
It is recommended that a signal be installed near the
motor to indicate that the space heaters are energized.
3.3.3.2 Insulation resistance
During the storage period, the insulation resistance of the
motor windings must be measured and recorded every
two months, and before the motor installation or eventually
if there is any change in the preservation process (E.g.
prolonged lack of electricity).
The measurement procedures and the criteria for
acceptance of the results shall be according to IEEE-43
Standard.
Any insulation resistance reduction must be investigated.
3.3.3.3 Exposed machined surfaces
All exposed machined surfaces (e.g., shaft end and
flanges) are protected at the factory with a temporary
protective agent (rust inhibitor).
This protection coating must be reapplied at least every
six months or when removed and/or damaged.
Recommended Product:
Supplier
: Fuchs
Protective agent Anticorit BW
3.3.3.4 Sealing
The rubber seals, gaskets, plugs and cable glands of the
motor shall be inspected annually and replaced, if
necessary.
16 l Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical 11371757
3.3.3.5 Bearings
ATTENTION
complete turns
ATTENTION
complete turns
ATTENTION
The shaft
in the
ATTENTION
3.3.3.5.1 Grease-lubricated rolling bearing
The rolling bearings are lubricated at the factory for the
motor tests.
In order to keep the bearings in good
condition during the storage period,
shaft locking device must be removed
every two months, and the motor rotor
must be rotated at least 10
at 30 rpm
preserve the internal parts of the bearings.
Before putting the motor into operation, the
rolling bearings must be lubricated;
If the motor remains stored for a period
exceeding two years, the rolling bearings must
be disassembled, washed, inspected and
relubricated.
the
to circulate the grease and
3.3.3.5.2 Oil-lubricated rolling bearing
Depending on the motor mounting position and on the
lubrication type, the motor can be transported with or
without oil in the bearings;
The motor storage must be done in its original
operating position and with oil in the bearings, when
specified;
The oil level must be respected, remaining in the
middle of the sight glass.
In order to keep the bearings in good
condition during the storage period,
shaft-locking device must be removed
every two months, and the motor rotor
must be rotated at least 10
at 30 rpm
the internal parts of the bearings.
Before putting the motor into operation, the rolling
bearings must be relubricated.
If the motor remains stored for a period exceeding 2
years, the rolling bearings must be disassembled,
washed, inspected and relubricated.
the
to circulate the oil and preserve
3.3.3.5.3 Sleeve bearing
Depending on the machine mounting position and the
lubrication type, the machine can be transported with or
without oil in the bearings.
The machine storage must be done in its original
operating position and with oil in the bearings, when so
specified.
The oil level must be respected, remaining in the middle of
the sight glass.
In order to keep the bearings in good conditions during
the storage period, the following preservation procedures
must be performed:
Close all the threaded holes with plugs;
Check if all the flanges (e.g., oil inlet and outlet
closed. If not, they must be closed with blind covers;
) are
www.weg.net
The oil level must be respected, remaining in the mi
of the oil sight glass;
Every two months, the shaft-locking device must be
removed, and the motor rotor must be rotated at least 10
complete turns at 30 rpm to circulate the oil and preserve
the internal parts of the bearings.
If the motor has a radial locking device, used
for transport, it must be replaced according
to item 4.2.3, so that the motor shaft tuning
can be performed.
NOTES
For bearings that have a high-pressure oil
injection system (jacking), this system must
be activated before rotating the machine
rotor.
For bearings without oil tank (dry crankcase),
the oil circulation system must be activated
before rotating the machine shaft.
machine rotation direction.
After six months of storage, the following procedure must
be used for protecting both the bearing internally and the
contact surfaces against corrosion:
Close all the threaded holes with plugs;
Seal the gaps between the shaft and the bearing seal
on the shaft by applying water-proof adhesive tape;
Check if all the flanges (e.g., oil inlet and outlet) are
closed. If not, they must be closed with blind covers;
Remove the upper sight glass from the bearing and
apply the corrosion inhibitor spray (TECTYL 511 or
equivalent) inside the bearing;
Close the bearing with the upper sight glass.
ach six months of storage, repeat the procedure
E
described above.
If the storage period exceeds two years, the bearing oil
must be replaced.
rotation must always be done
ddle
3.3.3.6 Terminal boxes
When the insulation resistance of the motor windings is
measured, the main terminal box and the other terminal
boxes must also be inspected, observing the following
aspects:
The inside must be dry, clean and free of any dust
accumulation;
The contact elements cannot present corrosion;
The seals must be in proper condition;
The cable inlets must be correctly sealed.
If any of these items are not in proper
condition, proceeds the adequate
maintenance and, if necessary, replace
damaged parts.
11371757 Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical l 17
www.weg.net
ATTENTION
The pressurized radiator
products, such as ammonia compounds and
3.3.3.7 Air-water heat exchanger
To ensure better conditions or the radiator storage for
long-term storage, the following criteria must be strictly
met:
Remove the flanged connections from the radiator to
gain access to it;
Drain the water inside the radiator tubes and heads
completely;
Blow hot air in one of the nozzles from 15 to 20 minutes
in order to eliminate humidity inside of radiator. For this
procedure, the radiator tubes shall be horizontally
placed, and the inlet and outlet water flanges placed in
such a way that the water are eliminated;
After dried, the nozzles shall be covered with blind
flanges with new sealing gaskets in order to assure a
perfect sealing;
Install a pressure gauge on one of the blind flanges
a globe valve on the other;
Pressurize the cooler with inert gas (Nitrogen or other)
at a pressure of 1.2 bar abs;
This pressure shall be checked monthly during the
radiator term storage, which shall not be exposed to
temperatures exceeding 50°C;
Considering that the storage procedure is followed, the
radiator seals must be replaced every 3 years, as
recommended by the radiator supplier.
with care. Use a warning plate informing that
the equipment is pressurized and should not
be exposed to temperatures exceeding
50°C.
must be handled
and
3.3.3.9 Inspections and records during storage
The stored motor must be inspected periodically and
inspection records must be filed.
The following items must be inspected:
1. Check the motor for physical damages and repair it, if
necessary;
2. Inspection of the cleanliness conditions;
3. Check for signs of water condensation inside the
motor;
4. Check of the protective coating conditions of the
exposed machined parts;
5. Check the paint conditions, and repair if necessary;
6. Check for aggressive agents signs;
7. Check the operation of the space heaters;
8. Measure and record the ambient temperature and
relative humidity around the motor;
9. Measure and record the temperature, insulation
resistance and polarization index of the stator winding;
10. Make sure that the storage location complies with the
criteria described in section 3.3.2.1.
3.3.3.10 Predictive / preventive maintenance
WEG recommends that, every 3 years of storage, the
stored motor be sent to a WEG Authorized Repair Shop or
to WEG own factory, in order to perform a complete
predictive maintenance.
The complete predictive maintenance procedure
comprises disassembling the complete motor for
inspection and, after assembly, performing a routine test in
the laboratory.
NOTE
During short operation stoppages, instead of
draining the water, it is preferable to keep its
circulation at low speeds through the heat
exchanger, thus ensuring that harmful
hydrogen sulfide, are taken out of the
radiator and not deposited inside.
3.3.3.8 Cleanliness and conservation of the
motor during storage
The motor should be free of oil, water, dust and dirt.
The motor outside must be cleaned with compressed
air under reduced pressure;
Remove the removable rust signs with a clean cloth
soaked in petroleum solvent.
Check that the bearings and lubrication hollows are free
of dust and dirt and if the bearing plugs are properly
tightened.
Risks, marks or rust on the shaft-end should be carefully
removed.
18 l Installation, operation and maintenance manual – Squirrel cage motor – M line – Vertical 11371757
Loading...
+ 41 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.